Clinical Trial Summary

This is a single-center, non-randomized study.The study staff will use the InSpectraTM tissue oxygen saturation (StO2) monitor manufactured by Hutchinson Technology to measure baseline StO2 levels after applying the noninvasive probe to the thenar eminence. After a stable reading is obtained, a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded. After 3 minutes or once the StO2 level comes to zero (whichever is earlier), the cuff pressure will be released and the rate of reperfusion (Rres; % × sec-1) will be measured. The investigators hypothesize that heart failure in children causes a baseline lower thenar tissue oxygen saturation (StO2), a faster rate of desaturation (Rdes) and a prolonged rate of reperfusion (Rres). The investigators also hypothesize that these changes will correlate with the severity of heart failure. The results of this study will provide groundwork for studies looking at correlation of therapy modification based on the combination thenar StO2 and clinical presentation.


Description:

Heart failure patients seen in the Pediatric Cardiology Congenital Heart Center will be enrolled into the study after obtaining informed consent on the day of their evaluation. The primary pediatric cardiologist following the patient will evaluate the need for regular investigations like blood work, electrocardiogram and echocardiogram. The study staff will use the InSpectraTM tissue oxygen saturation (StO2) monitor manufactured by Hutchinson Technology to measure the baseline StO2 level after applying the noninvasive probe to the thenar eminence. After a stable reading is obtained a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded. After 3 minutes or once the StO2 level comes to zero (whichever is earlier), the cuff pressure will be released and the rate of reperfusion (Rres; % × sec-1) will be measured. Similar measurements will be obtained from an otherwise healthy cohort of children who present to the Pediatric Cardiology Congenital Heart Center for evaluation of a heart murmur or chest pain. The patient's treating physician and care providers will be blinded to the study test results. All clinical care will be at the discretion of the patient's treating physicians. Only StO2 levels will be obtained using the non-invasive probe placed on the thenar eminence for the purpose of the study.


Recruitment information / eligibility

Status Recruiting
Enrollment 130
Est. completion date May 10, 2025
Est. primary completion date December 10, 2024
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group N/A to 25 Years
Eligibility Inclusion Criteria: - Heart failure patients under 25 years of age with a diagnosis of cardiomyopathy, myocarditis or univentricular palliation for congenital heart disease who are stable on their medical management will be enrolled. Exclusion Criteria: 1. Patients presenting with acute deterioration in clinical status 2. Patients with active infection 3. Patients with autoimmune vasculitis disorder 4. Patients with limb deformities and painful disorders of extremities 5. Patients with underlying bone disorders, (e.g. osteogenesis imperfecta) 6. Patients with severe anemia (Hb <7g/dL) 7. Patients with peripheral vascular disease which can alter the microcirculation

Study Design


Related Conditions & MeSH terms


Intervention

Device:
InSpectraTM StO2 monitor
InSpectraTM StO2 monitor manufactured by Hutchinson Technology Inc. to measure the baseline StO2 level after applying the noninvasive probe to the thenar eminence. After a stable reading is obtained a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded. After 3 minutes or once the StO2 level comes to zero, whichever is earlier the cuff pressure will be released instantaneously and the rate of reperfusion (Rres; % × sec-1) will be measured. The measurement will be continued until the StO2 returns to the baseline value.

Locations

Country Name City State
United States University of Florida Gainesville Florida

Sponsors (1)

Lead Sponsor Collaborator
University of Florida

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Baseline StO2 percentage The study staff will use the InSpectraTM StO2 monitor manufactured by Hutchinson Technology to measure the baseline StO2 level after applying the noninvasive probe to the thenar eminence Day 1
Secondary Occlusion- rate of desaturation (Rdes) of StO2 levels After a stable baseline reading is obtained a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded for 3 min or until the StO2 level comes to zero (whichever is earlier). Day 1
Secondary Recovery- rate of reperfusion (Rres) of StO2 levels After 3 minutes from occlusion or once the StO2 level comes to zero (whichever is earlier), the cuff pressure will be released and the rate of reperfusion (Rres; % × sec-1) will be measured for approximately 3 min. Day 1
See also
  Status Clinical Trial Phase
Recruiting NCT05196659 - Collaborative Quality Improvement (C-QIP) Study N/A
Recruiting NCT05654272 - Development of CIRC Technologies
Recruiting NCT05650307 - CV Imaging of Metabolic Interventions
Active, not recruiting NCT05896904 - Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction N/A
Completed NCT05077293 - Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
Recruiting NCT05631275 - The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
Enrolling by invitation NCT05564572 - Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology N/A
Enrolling by invitation NCT05009706 - Self-care in Older Frail Persons With Heart Failure Intervention N/A
Recruiting NCT04177199 - What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
Terminated NCT03615469 - Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY) N/A
Recruiting NCT06340048 - Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure Phase 1/Phase 2
Recruiting NCT05679713 - Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
Completed NCT04254328 - The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure N/A
Completed NCT03549169 - Decision Making for the Management the Symptoms in Adults of Heart Failure N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Enrolling by invitation NCT05538611 - Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
Recruiting NCT04262830 - Cancer Therapy Effects on the Heart
Completed NCT06026683 - Conduction System Stimulation to Avoid Left Ventricle Dysfunction N/A
Withdrawn NCT03091998 - Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support Phase 1
Recruiting NCT05564689 - Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy