Clinical Trials Logo

Clinical Trial Details — Status: Terminated

Administrative data

NCT number NCT05106413
Other study ID # SRF-377
Secondary ID
Status Terminated
Phase N/A
First received
Last updated
Start date October 26, 2021
Est. completion date March 14, 2022

Study information

Verified date November 2021
Source Sonova AG
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This study will evaluate the clinical benefit of a transmitter for contralateral routing of signals. The benefit will be evaluated in noisy environments regarding speech intelligibility when the CROS system is adjusted to different microphone settings. Additionally, data regarding overall system stability, crash reboot rate, sound quality and connectivity will be obtained over a period of time to validate the CROS system in combination with smartphone and accessories. This study is a confirmatory study.


Description:

Unilateral Hearing Loss (UHL) can be defined as any degree of permanent hearing loss on one ear with normal hearing in the opposite ear. Unilateral hearing loss can be debilitating associated with audiological, psychosocial and educational challenges. Audiological challenges include the reduced ability to localize sounds, reduced awareness on the unaidable side and difficulties hearing in noise or at a distance. One solution for unaidable UHL is Contralateral Routing of Signals (CROS) and Bilateral Contralateral routing of signals (BiCROS) using a so- called CROS transmitter together with a hearing aid. The rationale for this clinical investigation is to collect clinical data with a rechargeable CROS transmitter to evaluate the benefits of a BiCROS fitting compared to the alternative treatment option, the monaural hearing aid fitting, and to no treatment in noisy listening situations.


Recruitment information / eligibility

Status Terminated
Enrollment 23
Est. completion date March 14, 2022
Est. primary completion date March 14, 2022
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - hearing impaired adults, with & w/o hearing aids (experiences) - good written and spoken (Swiss) German language skills - ability to fill in a questionnaire conscientiously - informed consent as documented by signature - asymmetric hearing loss: one unaidable ear (min. N6 hearing loss) / the other ear with N3 or N4 hearing loss - availability of Smartphone - availability of TV or Tablet - ability to operate and handle the investigational device - ability to describe listening impressions/experiences and the use of the hearing aid - Ability to produce a reliable hearing test result Exclusion Criteria: - Contraindications to the medical device: - aidable hearing loss on the intended CROS side - acute tinnitus (in either one ear and occurrence less than three months) - anatomical deformity of the CROS ear (e.g. absence of the auricle) - Known hypersensitivity or allergy to materials of the investigational device - any auricle deformities, that prevents secure placement of the (test) devices - no willingness to test the investigational device system - no willingness to test the investigational device system for at least 8h a day - Hint for psychological problems from investigators point of view - reported fluctuating hearing that could influence the test result - reported symptoms of vertigo and dizziness by participants

Study Design


Related Conditions & MeSH terms


Intervention

Other:
BiCROS fitting
Each participant will be fitted with the experimental CROS device on the poorer, unaidable ear and with a compatible hearing device on the other ear.
Monaural fitting
Each participant will be fitted with a hearing aid on the better hearing ear and no device on the poorer, unaidable ear. Monaural hearing aid fitting acts as control intervention.
Unaided condition
No treatment, i.e. the participants are not fitted with a CROS device and/ or hearing aid. Unaided condition acts as control intervention.
CROS baseline
Each participant will be fitted with the experimental CROS device on the poorer, unaidable ear and with a compatible device on the other ear. The difference to the BiCROS condition is the setup of the microphones in the CROS device and the compatible hearing device. This test condition is only tested for speech intelligibility in diffuse noise and acts as control intervention.

Locations

Country Name City State
Switzerland Sonova AG Stäfa Zürich

Sponsors (1)

Lead Sponsor Collaborator
Sonova AG

Country where clinical trial is conducted

Switzerland, 

References & Publications (5)

Bagatto M, DesGeorges J, King A, Kitterick P, Laurnagaray D, Lewis D, Roush P, Sladen DP, Tharpe AM. Consensus practice parameter: audiological assessment and management of unilateral hearing loss in children. Int J Audiol. 2019 Dec;58(12):805-815. doi: 10.1080/14992027.2019.1654620. Epub 2019 Sep 5. Review. — View Citation

Lieu JE, Tye-Murray N, Karzon RK, Piccirillo JF. Unilateral hearing loss is associated with worse speech-language scores in children. Pediatrics. 2010 Jun;125(6):e1348-55. doi: 10.1542/peds.2009-2448. Epub 2010 May 10. — View Citation

McKay S, Gravel JS, Tharpe AM. Amplification considerations for children with minimal or mild bilateral hearing loss and unilateral hearing loss. Trends Amplif. 2008 Mar;12(1):43-54. doi: 10.1177/1084713807313570. Review. — View Citation

Snapp H. Nonsurgical Management of Single-Sided Deafness: Contralateral Routing of Signal. J Neurol Surg B Skull Base. 2019 Apr;80(2):132-138. doi: 10.1055/s-0039-1677687. Epub 2019 Jan 17. — View Citation

Snapp HA, Hoffer ME, Spahr A, Rajguru S. Application of Wireless Contralateral Routing of Signal Technology in Unilateral Cochlear Implant Users with Bilateral Profound Hearing Loss. J Am Acad Audiol. 2019 Jul/Aug;30(7):579-589. doi: 10.3766/jaaa.17121. Epub 2018 Dec 13. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Speech Intelligibility (SI) in noise (fix direction): BiCROS fitting vs. monaural hearing aid fitting The primary objective of this clinical investigation is to evaluate whether a BiCROS fitting (better ear fitted with a hearing device, unaidable ear supplied with a CROS device) improves speech intelligibility in noise compared to a monaural fitting (just the aidable ear is supplied by a hearing aid), for adults with an asymmetric hearing loss, measured with the Oldenburg Sentence Test (OLSA). Results of the speech test will be the SRT (speech recognition threshold) in dB SNR (signal to noise ratio).
The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).
The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).
2 weeks
Secondary SI in noise (fix direction): BiCROS fitting vs. unaided A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility in noise compared to an unaided condition, for adults with an asymmetric hearing loss, measured with the Oldenburg Sentence Test (OLSA).
Results of the speech test will be the SRT (dB SNR). The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).
The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).
2 week
Secondary SI in diffuse noise: BiCROS fitting vs. monaural fitting A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility by at least 1 dB SNR for 50% SRT in diffuse noise, compared to a monaural hearing aid fitting.
The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).
The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).
2 weeks
Secondary SI in diffuse noise: BiCROS fitting vs. unaided A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility by at least 1 dB SNR for 50% SRT in diffuse noise, compared to an unaided condition.
The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).
The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).
2 weeks
Secondary SI in diffuse noise: BiCROS vs. CROS baseline fitting A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility in diffuse noise compared with a CROS baseline fitting. CROS baseline means a fitting of an additional program with different hearing instrument microphone setup.
The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).
The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).
2 weeks
Secondary SI in diffuse noise: CROS baseline fitting vs. unaided A secondary objective of this clinical investigation is to evaluate whether a CROS baseline fitting improves speech intelligibility in diffuse noise compared with an unaided condition.
The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).
The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).
2 weeks
Secondary SI in diffuse noise: CROS baseline fitting vs. monaural fitting A secondary objective of this clinical investigation is to evaluate whether a CROS baseline fitting improves speech intelligibility in diffuse noise compared with a monaural fitting.
The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).
The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).
2 weeks
Secondary SP in diffuse noise: monaural fitting vs. unaided A secondary objective of this clinical investigation is to evaluate whether a monaural fitting improves speech intelligibility in diffuse noise compared with an unaided condition.
The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A).
The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A).
2 weeks
Secondary Evaluation of Sound quality A secondary objective of this study is to evaluate the participant's satisfaction of the sound quality of the experimental CROS device by a subjective rating during a three-week home trial period.
Scale: very unsatisfied- unsatisfied- neither nor- satisfied- very satisfied
3 weeks
Secondary Evaluation of System stability A secondary objective of this study is to evaluate the participant's satisfaction of the system stability of the experimental CROS device during a three-week home trial period.
The participant shall report, if there are artefacts audible: never/ 1-2 times a week/ 3-6 times a week/ daily
3 weeks
Secondary Evaluation of streaming A secondary objective of this study is to evaluate the participant's satisfaction of the streaming sound quality of the experimental CROS device, by a subjective rating during a three-week home trial period.
Scale: very unsatisfied- unsatisfied- neither nor- satisfied- very satisfied
3 weeks
Secondary Evaluation of listening effort A secondary objective is to evaluate the subjective listening effort in noise reported by the participant whilst wearing the experimental CROS device.
Scale: not at all - slightly - somewhat - moderately - very - extremely
3 weeks
See also
  Status Clinical Trial Phase
Recruiting NCT04696835 - fNIRS in Pediatric Hearing Aids N/A
Completed NCT03662256 - Reducing Childhood Hearing Loss in Rural Alaska Through a Preschool Screening and Referral Process Using Mobile Health and Telemedicine N/A
Completed NCT04602780 - Evaluating the Revised WORQ in CI Users
Completed NCT03723161 - Evaluation of the Ponto Bone Anchored Hearing System in a Pediatric Atresia Population
Completed NCT05086809 - Investigation of an Updated Bone-anchored Sound Processor N/A
Active, not recruiting NCT03548779 - North Carolina Genomic Evaluation by Next-generation Exome Sequencing, 2 N/A
Completed NCT03428841 - Audiovisual Assessment After Dural Puncture During Epidural Placement in Obstetric Patients N/A
Completed NCT04559282 - Home Test of New Sound Processor N/A
Enrolling by invitation NCT03345654 - Individually-guided Hearing Aid Fitting
Completed NCT06016335 - MRI-based Synthetic CT Images of the Head and Neck N/A
Completed NCT05165121 - Comparison of Hearing Aid Fitting Outcomes Between Self-fit and Professional Fit for MDHearing Smart Hearing Aids N/A
Recruiting NCT05533840 - Establishment and Application of a New Imaging System for Otology Based on Ultra-high Resolution CT
Terminated NCT02294812 - Effects of Cognitive Training on Speech Perception N/A
Completed NCT04622059 - AUditive Direct In-utero Observation (AUDIO): Prenatal Testing of Congenital Hypoacusis N/A
Recruiting NCT02558478 - Identification of New Genes Implicated in Rare Neurosensory Diseases by Whole Exome Sequencing N/A
Withdrawn NCT02740322 - Validating the Hum Test N/A
Completed NCT01963104 - Community-Based Kiosks for Hearing Screening and Education N/A
Completed NCT01857661 - The Influence of the Sound Generator Combined With Conventional Amplification for Tinnitus Control: Blind Randomized Clinical Trial N/A
Completed NCT01892007 - Evaluation of Cogmed Working Memory Training for Adult Hearing Aid Users N/A
Withdrawn NCT01223638 - The Prevalence of Hearing Loss Among Children With Congenital Hypothyroidism N/A