Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT06213896
Other study ID # EC-2023-TR
Secondary ID
Status Completed
Phase
First received
Last updated
Start date March 1, 2023
Est. completion date April 18, 2024

Study information

Verified date January 2024
Source URAL Telekomunikasyon San. Trade Inc.
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

Eye health is of great importance for quality of life. Some eye diseases can progress and cause permanent damage up to vision loss if they are not treated early. Therefore, it is of great importance to have regular eye examinations and to detect possible eye diseases before they progress. Healthy people should also undergo eye screening once a year, and those with any complaints regarding eye health should be examined. With the advancing technology, Artificial Intelligence (AI) has begun to play a significant role in the healthcare sector. Retinal diseases, serious health problems resulting from damage to the back part of the eye's retina, include conditions such as retinopathy, macular degeneration, and glaucoma. Artificial intelligence, with its visual recognition and analysis capabilities, holds great potential in the early diagnosis of retinal diseases. AI-based diagnosis of retinal diseases typically involves the use of specialized algorithms that analyze retinal images. These algorithms identify abnormal features in the eye, providing doctors with a quick and accurate diagnosis. EyeCheckup v2.0 will diagnose glaucoma suspicion, severe glaucoma suspicion, age-related macular degeneration diagnosis, RVO diagnosis, diabetic retinopathy diagnosis and stage, presence/absence of DME suspicion and other retinal diseases from fundus images. This study is designed to assess the safety and efficacy of EyeCheckup v2.0. The study is a single center study to determine the sensitivity and specificity of EyeCheckup to retinal and optic disc diseases. EyeCheckup v2.0 is an automated software device that is designed to analyze ocular fundus digital color photographs taken in frontline primary care settings in order to quickly screen.


Description:

According to the World Health Organization's worldwide report published in 2020, at least 2.2 billion people worldwide currently have visual impairment, and at least 1 billion of them have a visual impairment that can be prevented or has not yet been addressed. The world faces significant eye health challenges, including inequalities in the coverage and quality of eye care prevention, treatment, and rehabilitation services, a lack of trained eye care providers, and poor integration of eye care services into health systems, among others. It is known that more than 80% of all visual disorders can be prevented or treated. An eye fundus examination must be performed by a retina specialist to make a correct diagnosis, but people only consult an ophthalmologist when they feel any discomfort. While typically symptoms progress so much that once a disease occurs, resulting in expensive treatments and surgeries, often the damage is irreversible, resulting in visual impairment or even permanent vision loss. Artificial intelligence is used to study and develop theories and methods that can help simulate and extend human intelligence, which have been used in many fields of research such as automatic diagnosis and medicine. In recent years, the intersection of artificial intelligence (AI) technology and modern medicine has made effective and rapid disease screening possible. EyeCheckup is an automated software device designed to analyze digital color photographs of the ocular fundus to quickly screen for retinal and optic disc diseases. The main aim of the research is to evaluate the performance of the automatic screening algorithm to detect steerable retinal and optic disc diseases based on color fundus images and to determine its sensitivity and specificity towards possible diseases. For the clinical validation of the system, the images will be evaluated by ophthalmologists and the results will be compared with the artificial intelligence algorithm. After exclusions, this study will enroll up to 1528 subjects that meet the eligibility criteria. Participants who meet the eligibility criteria will be recruited after obtaining written informed consent from primary health care providers. Subjects will undergo fundus photography per, Food and Drug Administration (FDA) cleared, ophthalmic cameras. Images will be taken according to a specific EyeCheckup imaging protocol provided to the ophthalmic camera operator and then analyzed by the EyeCheckup v2.0 device. Methods and tools to be used in the research: I. Fundus photo capturing with non-mydriatic cameras: Optic disc-centered and fovea-centered fundus images will be taken with Canon CR-2 AF, Topcon TRC-NW400 and Optomed Aurora Non-mydriatic fundus cameras. For volunteers whose non-mydriatic images cannot be obtained, pupil dilation will be achieved by instilling tropicamide drops, and then images will be taken. Canon CR-2 AF, Topcon TRC-NW400 and Optomed Aurora Non-mydriatic fundus cameras, from which retina images will be taken, are CE marked and FDA approved. Tests to be done: I. Fundus images obtained with three different cameras from each volunteer included in the study will be analyzed separately for both the right eye and the left eye by the EyeCheckup artificial intelligence algorithm on a camera-based basis. ii. Evaluation of Canon CR-2 AF images by retina and glaucoma specialists for clinical validation of the system and comparison of the results,


Recruitment information / eligibility

Status Completed
Enrollment 1528
Est. completion date April 18, 2024
Est. primary completion date April 18, 2024
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: Must understand the study and sign informed consent. No history of retinal vascular disease, cataracts or any other disease that may affect the appearance of the retina or optic disc (refractive error and ocular surface disease are allowed). No history of intraocular surgery or ocular laser treatment for any retinal disease, other than cataract surgery. 18 years and over Exclusion Criteria: Not understand the study or informed consent, Media opacity or other defect that would prevent taking a fundus photograph with the feature to be evaluated (which could not be taken with a non-mydriatic fundus camera in 6 attempts or was rejected 6 times by the EyeCheckup quality algorithm due to quality), Has intraocular surgery other than cataracts or has had laser treatment on the retina, Contraindicated for imaging with the fundus imaging systems used in the study, Under 18 years

Study Design


Intervention

Drug:
Mydriatic Agent
Subjects will be administered mydriatic medication to dilate their pupils.
Procedure:
Color Fundus Photography
Subjects will undergo fundus photography before and after administration of mydriatic agent.
Device:
EyeCheckup v2.0
Screening for existence of eye diseases

Locations

Country Name City State
Turkey Akdeniz University Hospital Antalya

Sponsors (1)

Lead Sponsor Collaborator
URAL Telekomunikasyon San. Trade Inc.

Country where clinical trial is conducted

Turkey, 

Outcome

Type Measure Description Time frame Safety issue
Primary To determine the accuracy of diagnosis with artificial intelligence algorithm Comparison of the compatibility of the diagnosis of the artificial intelligence algorithm with the diagnoses of retina and glaucoma specialists through study completion, an average of 1 year
Secondary To determine the sensitivity and specificity of EyeCheckup v2.0 to detect retinal and optic disc diseases To determine the sensitivity of EyeCheckup v2.0 to detect Glaucoma, RVO, diabetic retinopathy, suspected DME, ARMD, other retinal disease (True positive rate of the algorithm)
To determine the specificity of EyeCheckup v2.0 to detect Glaucoma, RVO, diabetic retinopathy, suspected DME, ARMD, other retinal disease (True negative rate of the algorithm)
To determine the specificity of EyeCheckup v2.0 to detect Refere/Nonrefere (True negative rate of the algorithm)
To determine the sensitivity of EyeCheckup v2.0 to detect Refere/Nonrefere (True positive rate of the algorithm)
through study completion, an average of 1 year
See also
  Status Clinical Trial Phase
Recruiting NCT06000865 - Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE N/A
Recruiting NCT06278597 - Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03274024 - The Asia Primary Tube Versus Trab (TVT) Study N/A
Completed NCT04552964 - Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma N/A
Recruiting NCT01957267 - Functional and Structural Imaging for Glaucoma
Active, not recruiting NCT04624698 - iStent Inject New Enrollment Post-Approval Study N/A
Completed NCT04020705 - The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma N/A
Completed NCT03150160 - Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma Phase 4
Not yet recruiting NCT05581498 - Glaucoma Exercise as Medicine Study (GEMS). N/A
Recruiting NCT02921568 - Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes N/A
Active, not recruiting NCT02901730 - Clinical Study of LPI With Different Laser Wavelengths N/A
Completed NCT02955849 - A Trial of China Laser and Surgery Study Glaucoma in Rural China Early Phase 1
Recruiting NCT02554214 - Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device N/A
Recruiting NCT02471105 - Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml Phase 4
Active, not recruiting NCT02390284 - Stop Retinal Ganglion Cell Dysfunction Study Phase 3
Completed NCT02246764 - Study of Netarsudil (AR-13324) Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension Phase 3
Completed NCT02653963 - Triamcinolone for Ahmed Glaucoma Valve N/A
Completed NCT02390245 - Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study N/A
Completed NCT02628223 - 180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma N/A