Glaucoma Clinical Trial
Official title:
Comparison of a Novel Head-Mounted Perimeter Versus the Humphrey Field Analyzer
NCT number | NCT05674890 |
Other study ID # | 202206347 |
Secondary ID | |
Status | Completed |
Phase | N/A |
First received | |
Last updated | |
Start date | January 3, 2023 |
Est. completion date | June 1, 2023 |
Verified date | March 2024 |
Source | University of Iowa |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The goal of this clinical trial is to compare a new device for testing peripheral vision (the SmartSystem virtual reality headset) to the currently most commonly used standard testing device (the Humphrey HFA-III). The main questions this clinical trials aims to answer are: 1. How comparable in performance, accuracy, and patient comfort the SmartSystem VR headset is to the Humphrey HFA-III, and 2. Surveying patients about the perceived ease of use and patient experience with the SmartSystem VR headset, compared to the Humphrey HFA-III. Participants will be asked to use the SmartSystem VR headset to take an additional visual field test (which takes between 10 to 15 minutes to do) and to take a brief survey about their experience. This will occur on regularly scheduled clinic visits and done in addition to the standard tests and examinations scheduled for that day. Researchers will compare the patients' test results and survey responses for both the SmartSystem VR headset and the Humphrey HFA-III to see which has more favorable performance, reliability, duration of testing and user experience.
Status | Completed |
Enrollment | 52 |
Est. completion date | June 1, 2023 |
Est. primary completion date | June 1, 2023 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 100 Years |
Eligibility | Inclusion Criteria: - Patients between 18-100 years of age with suspected, mild, moderate, or severe glaucoma Exclusion Criteria: - Non-English speakers, patients with systemic or ocular disease affecting central vision, best corrected visual acuity less than 20/80, neurocognitive or psychiatric disorders that would confound visual field testing, those with physical inability to perform testing, and astigmatism with absolute values greater than 2.00 diopters |
Country | Name | City | State |
---|---|---|---|
United States | University of Iowa | Iowa City | Iowa |
Lead Sponsor | Collaborator |
---|---|
Andrew Pouw, MD |
United States,
Beck RW, Bergstrom TJ, Lichter PR. A clinical comparison of visual field testing with a new automated perimeter, the Humphrey Field Analyzer, and the Goldmann perimeter. Ophthalmology. 1985 Jan;92(1):77-82. doi: 10.1016/s0161-6420(85)34065-4. — View Citation
Hollander DA, Volpe NJ, Moster ML, Liu GT, Balcer LJ, Judy KD, Galetta SL. Use of a portable head mounted perimetry system to assess bedside visual fields. Br J Ophthalmol. 2000 Oct;84(10):1185-90. doi: 10.1136/bjo.84.10.1185. — View Citation
Mees L, Upadhyaya S, Kumar P, Kotawala S, Haran S, Rajasekar S, Friedman DS, Venkatesh R. Validation of a Head-mounted Virtual Reality Visual Field Screening Device. J Glaucoma. 2020 Feb;29(2):86-91. doi: 10.1097/IJG.0000000000001415. — View Citation
Nakai Y, Bessho K, Shono Y, Taoka K, Nakai Y. Comparison of imo and Humphrey field analyzer perimeters in glaucomatous eyes. Int J Ophthalmol. 2021 Dec 18;14(12):1882-1887. doi: 10.18240/ijo.2021.12.11. eCollection 2021. — View Citation
Quigley HA, Broman AT. The number of people with glaucoma worldwide in 2010 and 2020. Br J Ophthalmol. 2006 Mar;90(3):262-7. doi: 10.1136/bjo.2005.081224. — View Citation
Quigley HA. Number of people with glaucoma worldwide. Br J Ophthalmol. 1996 May;80(5):389-93. doi: 10.1136/bjo.80.5.389. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Visual Field Reliability Metric #1 - False Positive Rate | In perimetry (visual field testing), a "false positive error" occurs when a subject/patient records a response when no stimulus is presented. This is one metric by which the reliability of a visual field test is measured. The measurement is reported as a percentage. | This measurement will automatically be reported upon conclusion of each visual field test. Visual field testing is estimated to take 5-15 minutes for each visual field test. All testing will occur on the same day within a 1-2 hour period. | |
Primary | Visual Field Reliability Metric #2 - False Negative Rate | In perimetry (visual field testing), a "false negative error" occurs when a subject/patient fails to record a response to a stimulus that is brighter than one they had previously responded to in the same visual location. This is one metric by which the reliability of a visual field test is measured. The measurement is reported as a percentage. | This measurement will automatically be reported upon conclusion of each visual field test. Visual field testing is estimated to take 5-15 minutes for each visual field test. All testing will occur on the same day within a 1-2 hour period. | |
Primary | Visual Field Reliability Metric #3 - Fixation Loss Rate | In perimetry (visual field testing), a "fixation loss" occurs when a subject/patient records a response to a stimulus presented in the physiologic blind spot. If the patient responds, it indicates their gaze is not fixed straight ahead. This is one metric by which the reliability of a visual field test is measured. The measurement is reported as a percentage. | This measurement will automatically be reported upon conclusion of each visual field test. Visual field testing is estimated to take 5-15 minutes for each visual field test. All testing will occur on the same day within a 1-2 hour period. | |
Primary | Visual Field Performance Metric #1 - Mean Deviation | Mean deviation indicates how much, on average, an entire visual field deviates from the age-normal value. It is the center-weighted average of the decibel deviations at each point tested in the visual field test. The measurement is reported in decibels. | This measurement will automatically be reported upon conclusion of each visual field test. Visual field testing is estimated to take 5-15 minutes for each visual field test. All testing will occur on the same day within a 1-2 hour period. | |
Primary | Visual Field Performance Metric #2 - Pattern Standard Deviation | Pattern standard deviation reflects irregularities in a visual field, such as those caused by localized defects. This metric shows sensitivity losses after adjusting for generalized depression or elevation in the overall hill of vision (e.g. cataracts). The measurement is reported in decibels. | This measurement will automatically be reported upon conclusion of each visual field test. Visual field testing is estimated to take 5-15 minutes for each visual field test. All testing will occur on the same day within a 1-2 hour period. | |
Primary | Visual Field Performance Metric #3 - Total Deviation | Total deviation probability plots identify test locations that are outside normal limits. Threshold sensitivity levels are compared to age-corrected normal values at each test location to produce a total deviation map. Each measurement is reported in decibels. | These measurements will automatically be reported upon conclusion of each visual field test. Visual field testing is estimated to take 5-15 minutes for each visual field test. All testing will occur on the same day within a 1-2 hour period. | |
Primary | Visual Field Performance Metric #4 - Foveal Threshold | Foveal threshold is the minimum amount of luminance increment on a uniform background that can be detected by a subject/patient at the center of fixation. The measurement is reported in decibels. | This measurement will automatically be reported upon conclusion of each visual field test. Visual field testing is estimated to take 5-15 minutes for each visual field test. All testing will occur on the same day within a 1-2 hour period. | |
Primary | Visual Field Performance Metric #5 - Mean Threshold per Garway-Heath Sector | This metric indicates how much, on average, the threshold values in each Garway-Heath sector (a commonly used mapping method with established precedent in this area of research) deviate from the age-normal value. It is the average of the decibel deviations at each point tested in the sector. The measurement is reported in decibels. | These measurements will be derived during data analysis following study completion. The exact study duration is unclear; however, we aim to recruit enough patients to analyze 80 eyes worth of data. We estimate this will take 3-6 months. | |
Secondary | Visual Field User Experience Question #1 - "How would you rate the comfort of the [Humphrey Field Analyzer/Smart System Virtual Reality Headset]?" | This question will be rated using a Likert scale. Response options will include "very uncomfortable", "uncomfortable", "neutral", "comfortable", and "very comfortable". | Subjects will respond to an approximately 5-10 minute survey upon completion of both visual field tests. The survey will be administered the same day as visual field testing at the conclusion of the estimated 1-2 hour period. | |
Secondary | Visual Field User Experience Question #2 - "How hard or easy was it to understand the instructions given to you for how to do the visual field test using the [Humphrey Field Analyzer/Smart System Virtual Reality Headset]?" | This question will be rated using a Likert scale. Response options will include "very hard", "hard", "neutral", "easy", and "very easy". | Subjects will respond to an approximately 5-10 minute survey upon completion of both visual field tests. The survey will be administered the same day as visual field testing at the conclusion of the estimated 1-2 hour period. | |
Secondary | Visual Field User Experience Question #3 - "How hard or easy was it to use and/or perform the visual field test using the [Humphrey Field Analyzer/Smart System Virtual Reality Headset]?" | This question will be rated using a Likert scale. Response options will include "very hard", "hard", "neutral", "easy", and "very easy". | Subjects will respond to an approximately 5-10 minute survey upon completion of both visual field tests. The survey will be administered the same day as visual field testing at the conclusion of the estimated 1-2 hour period. | |
Secondary | Visual Field User Experience Question #4 - "How much anxiety or concern did you have about your test performance while using the [Humphrey Field Analyzer/Smart System Virtual Reality Headset]?" | This question will be rated using a Likert scale. Response options will include "very anxious/concerned", "anxious/concerned", "neutral", "relaxed", and "very relaxed". | Subjects will respond to an approximately 5-10 minute survey upon completion of both visual field tests. The survey will be administered the same day as visual field testing at the conclusion of the estimated 1-2 hour period. | |
Secondary | Visual Field User Experience Question #5 - "Given instruction and training, would you feel comfortable performing visual field testing by yourself at home using the Smart System Virtual Reality Headset?" | Response options will include "yes", "no", and "maybe". | Subjects will respond to an approximately 5-10 minute survey upon completion of both visual field tests. The survey will be administered the same day as visual field testing at the conclusion of the estimated 1-2 hour period. | |
Secondary | Visual Field User Experience Question #6 - "If the Smart System Virtual Reality Headset were available for home use, would you use it?" | Response options will include "yes", "no", and "maybe". | Subjects will respond to an approximately 5-10 minute survey upon completion of both visual field tests. The survey will be administered the same day as visual field testing at the conclusion of the estimated 1-2 hour period. | |
Secondary | Visual Field User Experience Question #7 - "Which visual field test would you rather use at follow-up visits?" | Response options will include "Humprey Field Analyzer", "Smart System Virtual Reality Headset", and "unsure". | Subjects will respond to an approximately 5-10 minute survey upon completion of both visual field tests. The survey will be administered the same day as visual field testing at the conclusion of the estimated 1-2 hour period. |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06000865 -
Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE
|
N/A | |
Recruiting |
NCT06278597 -
Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03274024 -
The Asia Primary Tube Versus Trab (TVT) Study
|
N/A | |
Completed |
NCT04552964 -
Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma
|
N/A | |
Recruiting |
NCT01957267 -
Functional and Structural Imaging for Glaucoma
|
||
Active, not recruiting |
NCT04624698 -
iStent Inject New Enrollment Post-Approval Study
|
N/A | |
Completed |
NCT04020705 -
The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma
|
N/A | |
Completed |
NCT03150160 -
Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma
|
Phase 4 | |
Not yet recruiting |
NCT05581498 -
Glaucoma Exercise as Medicine Study (GEMS).
|
N/A | |
Recruiting |
NCT02921568 -
Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes
|
N/A | |
Active, not recruiting |
NCT02901730 -
Clinical Study of LPI With Different Laser Wavelengths
|
N/A | |
Completed |
NCT02955849 -
A Trial of China Laser and Surgery Study Glaucoma in Rural China
|
Early Phase 1 | |
Recruiting |
NCT02471105 -
Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml
|
Phase 4 | |
Recruiting |
NCT02554214 -
Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device
|
N/A | |
Active, not recruiting |
NCT02390284 -
Stop Retinal Ganglion Cell Dysfunction Study
|
Phase 3 | |
Completed |
NCT02628223 -
180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma
|
N/A | |
Completed |
NCT02653963 -
Triamcinolone for Ahmed Glaucoma Valve
|
N/A | |
Completed |
NCT02390245 -
Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study
|
N/A | |
Completed |
NCT02246764 -
Study of Netarsudil (AR-13324) Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension
|
Phase 3 |