Outcomes Comparison Between Baerveldt 350 and Ahmed ClearPath 250 Tube Shunts for the Treatment of Glaucoma
To compare the safety and efficacy of Baerveldt 350 and Ahmed ClearPath 250 tube shunts in lowering IOP in glaucoma patients.
Tube shunt implantation is a common type of surgery considered standard of care for treating significant potentially-blinding glaucoma where medical and laser treatment, and previous surgeries, have failed to control intra-ocular pressure (IOP) sufficiently to stop glaucoma progression towards blindness. Since a larger plate tube (e.g., Baerveldt 350) is more difficult to implant requiring longer surgical time and intraoperative ocular muscle manipulation with possible patient discomfort, a smaller plate tube shunt (e.g., Ahmed ClearPath 250) requiring shorter surgical time and no ocular muscle manipulation may have an advantage if the long term surgical outcomes were the same. However, the literature is lacking regarding the effect of the tube plate size on the final outcomes of tube shunt implantation. Most published comparisons are between totally different types of tube shunts regardless of plate size, often made of different materials, often comparing valved vs. non-valved tube shunts,combining different plate sizes in the same study groups,5 mixing tubes with or without combined cataract surgery in the same study groups, or comparing surgeries performed by several surgeons utilizing different surgical methods. Further, all these studies utilize tubes implanted into the anterior chamber (AC) thus increasing the risk of corneal failure, with no comparisons at all between tube shunts implanted through the ciliary sulcus of the eye designed to reduce the risk of corneal failure. Our Principle Investigator (AW) is specializing and well-published in this type of tube shunt implantation. This prospective randomized trial is designed to resolve all these confusing factors in the literature and finally provide the answer of whether tube plate size has an effect on the final outcomes of tube shunt implantation by performing a "clean" study that would isolate the effect of tube plate size on long term outcomes. To achieve this goal our study will utilize two non-valved tube shunts with a different plate size (350 vs. 250 mm2) made of identical materials, in eyes that have already had cataract surgery, and all performed by the same surgeon (AW) through the ciliary sulcus. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06000865 -
Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE
|
N/A | |
Recruiting |
NCT06278597 -
Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03274024 -
The Asia Primary Tube Versus Trab (TVT) Study
|
N/A | |
Completed |
NCT04552964 -
Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma
|
N/A | |
Recruiting |
NCT01957267 -
Functional and Structural Imaging for Glaucoma
|
||
Active, not recruiting |
NCT04624698 -
iStent Inject New Enrollment Post-Approval Study
|
N/A | |
Completed |
NCT04020705 -
The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma
|
N/A | |
Completed |
NCT03150160 -
Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma
|
Phase 4 | |
Not yet recruiting |
NCT05581498 -
Glaucoma Exercise as Medicine Study (GEMS).
|
N/A | |
Recruiting |
NCT02921568 -
Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes
|
N/A | |
Active, not recruiting |
NCT02901730 -
Clinical Study of LPI With Different Laser Wavelengths
|
N/A | |
Completed |
NCT02955849 -
A Trial of China Laser and Surgery Study Glaucoma in Rural China
|
Early Phase 1 | |
Recruiting |
NCT02471105 -
Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml
|
Phase 4 | |
Recruiting |
NCT02554214 -
Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device
|
N/A | |
Active, not recruiting |
NCT02390284 -
Stop Retinal Ganglion Cell Dysfunction Study
|
Phase 3 | |
Completed |
NCT02520674 -
Glaucoma Screening With Smartphone Ophthalmology
|
N/A | |
Completed |
NCT02246764 -
Study of Netarsudil (AR-13324) Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension
|
Phase 3 | |
Completed |
NCT02390245 -
Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study
|
N/A | |
Completed |
NCT02628223 -
180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma
|
N/A |