Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT04024293
Other study ID # GF-1801-S
Secondary ID
Status Not yet recruiting
Phase N/A
First received
Last updated
Start date November 2023
Est. completion date March 2024

Study information

Verified date June 2023
Source Sensimed AG
Contact Kaweh Mansouri, Pr
Phone +41 21 619 36 02
Email kwmansouri@gmail.com
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

While elevated intraocular pressure (IOP) is no longer part of the definition of glaucoma it remains the sole proven modifiable risk factor for the onset and progression of glaucoma. IOP is known to vary with the time of day as well as with daily activities. The importance of the nycthemeral IOP pattern for successful management of glaucoma has been well documented, especially for patients who experience visual loss despite apparently normal and/or controlled IOP during office hours. The current way of assessing nycthemeral IOP fluctuation is to perform repeated discrete tonometry measurements, once per hour in the best cases. Since its development in the 50s, Goldmann applanation tonometry (GAT) has remained the gold standard method for measuring IOP, despite its limitations. However, tonometry may be an imperfect method for measuring changes in IOP because it allows only snapshot and non-continuous measurements, it is not physiologic and disturbs the sleep architecture. There have been many efforts in the past decades to search for an ambulatory and frequent method to monitor IOP for 24 hours. In this context, Sensimed AG has recently developed a sensing contact lens-based device intended to measure IOP over 24 hours, the Goldfish (GF). First-in-man data obtained with this device showed agreements between IOP measured by GF and values obtained by standard tonometry in the same eye, comparable to literature results for routinely used tonometry devices. However, this pilot study included 9 subjects only with improvable safety, tolerability and efficacy profiles. The main goal of this study is to assess IOP measurements with the GF and compare the values with those obtained by standard tonometry in patients with open angle glaucoma (OAG) and ocular hypertension (OHT).


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 12
Est. completion date March 2024
Est. primary completion date February 2024
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Informed Consent - A clinical diagnosis of primary open angle glaucoma (POAG), including normal tension glaucoma (NTG), for OAG patients - A clinical diagnosis of OHT, for OHT patients - For all patients: Open angles on gonioscopy Aged = 18 years, either gender Both central corneal radii (CCR) between 7.3mm (46.23D) and 8.05mm (41.93D), with a maximum difference of 2D between the 2 radii in the study eye Central corneal thickness (CCT) between 490µm and 600µm in the study eye Exclusion Criteria: - Ocular pathology (other than glaucoma or OHT) - Previous glaucoma, cataract or refractive laser/surgery - Corneal or conjunctival abnormality, precluding contact lens adaptation - Insufficiency of lacrimal secretion - Subjects with allergy to corneal anesthetic - Subjects with contraindications for silicone contact lens wear - Subjects with contraindications for Diamox or Latanoprost or Timolol - Skin irritations, skin eczema or other indications against the wearing of adhesive patches - Subjects unable or unwilling to comply with the study procedures - Subjects lacking the capacity to consent (vulnerable persons) - Subjects with history of cardiac failure, treated cardiopathy or renal failure - Subjects with known cognitive disorders - Inability to follow the procedures of the study, e.g. due to language problems, psychological disorders, dementia, etc. of the participant, - Participation in another study with investigational drug within the 30 days preceding and during the present study, - Enrolment of the investigator, his/her family members, employees and other dependent persons.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Goldfish (GF)
The GF lens (SCL) will be place on participant's eye for a 24h IOP recording session

Locations

Country Name City State
Switzerland Clinique Montchoisi Lausanne Vaud

Sponsors (1)

Lead Sponsor Collaborator
Sensimed AG

Country where clinical trial is conducted

Switzerland, 

Outcome

Type Measure Description Time frame Safety issue
Primary GF IOP measurement as compared to IOP Differences between GF IOP measurements at the recording start/end and the values obtained by GAT before/after GF SCL placement/removal, in the same eye 24 hours
See also
  Status Clinical Trial Phase
Recruiting NCT06000865 - Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE N/A
Recruiting NCT06278597 - Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03274024 - The Asia Primary Tube Versus Trab (TVT) Study N/A
Completed NCT04552964 - Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma N/A
Recruiting NCT01957267 - Functional and Structural Imaging for Glaucoma
Active, not recruiting NCT04624698 - iStent Inject New Enrollment Post-Approval Study N/A
Completed NCT04020705 - The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma N/A
Completed NCT03150160 - Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma Phase 4
Not yet recruiting NCT05581498 - Glaucoma Exercise as Medicine Study (GEMS). N/A
Recruiting NCT02921568 - Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes N/A
Active, not recruiting NCT02901730 - Clinical Study of LPI With Different Laser Wavelengths N/A
Completed NCT02955849 - A Trial of China Laser and Surgery Study Glaucoma in Rural China Early Phase 1
Recruiting NCT02471105 - Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml Phase 4
Recruiting NCT02554214 - Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device N/A
Active, not recruiting NCT02390284 - Stop Retinal Ganglion Cell Dysfunction Study Phase 3
Completed NCT02246764 - Study of Netarsudil (AR-13324) Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension Phase 3
Completed NCT02520674 - Glaucoma Screening With Smartphone Ophthalmology N/A
Completed NCT02628223 - 180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma N/A
Completed NCT02653963 - Triamcinolone for Ahmed Glaucoma Valve N/A