The goal of this prospective, single centre, 1:1, Post Market, randomized controlled, Investigator Initiated trial, is to compare the feasibility, safety efficacy, and clinical outcomes of colonic endoscopic submucosal dissection (ESD) utilizing a novel rigidizing overtube called Pathfinder® Endoscope Overtube (Neptune Medical, Burlingame California, USA) device in comparison to conventional ESD. The research team hypothesize that with utilizing a novel rigidizing overtube the procedure time including dissection speed and closure time will be faster due to higher scope stability and greater control over the scope tip. Subsequently, the investigators anticipate lower immediate or delayed adverse events.


Clinical Trial Description

Endoscopic submucosal dissection (ESD) is preferred resection method for advanced colonic polyp due to its higher rates of en bloc and R0 resection which lead to higher curative resection rate.1 In comparison to gastric ESD, colonic ESD is more challenging due to colonic unique anatomy and configuration. Tumor of size ≥ 50 mm, spreading across ≥ two folds, flexure locations have been described as strong predictors for difficulties during colonic ESD.2 Redundant colon and looping during colonoscopy may preclude successful advancement of the colonoscope and maintaining stable position for complex polyp removal. Historically, various methods have been applied to facilitate colonoscopy and scope advancement in challenging positions and redundant colonic loops such as application of external pressure, exchange to pediatric colonoscope, torque-based reduction maneuvers, and patient repositioning. However, despite these, scope tip stabilization could potentially remain as a challenging and limiting factor for procedure progress and could lead to a longer procedure time, sedation time and perhaps lower procedure success rate. In comparison overtube-assisted colonoscopy allows for straightening of the colon to decrease angulation and loop formation.3 Several variations of overtubes have been put to use in the last few decades with comparable results such as single-balloon and double-balloon enteroscope, spiral overtube-assisted colonoscopy and double-balloon platform (DiLumenTM). DiLumen system consists of a plastic sheet fitting layer with two balloon few inches from each other in the tip of the device facilitating the scope tip stability. Most recently the efficacy of DiLumen platform were evaluated in a multicenter study including 162 patients who underwent endoscopic resection of advanced polyps.4 In this study technical success was achieved in 92% of patients without any device related adverse event. 4 In this study using an overtube resulted in faster and more efficient dissection.4 In a retrospective study of 88 polyps located within the proximal colon, ESD with assistance of traditional single balloon overtube resulted in significantly less perforation rate in polyps ≥ 40mm in the proximal colon, despite overall similar en bloc and R0 resection rates comparison to conventional ESD.5 Most recently, a novel dynamic rigidizing overtube (Pathfinder, Neptune Medical, Burlingame, Calif, USA) has been introduced to face the challenges encountered during difficult colonoscopies and to ensure scope stabilization during endoscopic mucosal resection (EMR) and ESD. The overtube material is soft and pliable on flexible state, however when the vacuum is applied the entire tube becomes 15 times stiffer.6 This unique feature of the device provides scope flexibility during colonoscope introduction and entire device stability when rigidizing system is applied. Our team collected preliminary prospective data of 58 polyps removed by EMR (24.1%) and ESD (75.9% ) with the assistance off rigidizing overtube. Technical success (ability to complete the entire resection using the device) and clinical success (ability of endoscopic removal of polyps without changing the initial resection intent) was achieved 100% and 90% of the time, respectively. On endoscopist feedback, the rigidizing overtube was though to assist in resection in 98.3% of polyps, although the polyp was located in a somewhat/very difficult location 81% of the time. For polyps in difficult locations, the rigidizing overtube was able to maintain scope position without falling back even once, 55% of the time. This result was presented at the most recent Digestive Disease Week conference in Chicago 2023 (p1932). As this device has been put to use recently in the United States, published literature to demonstrate its safety and efficacy in colonic ESD is lacking. The main aim of this study is to compare the feasibility, safety efficacy, and clinical outcomes of colonic endoscopic submucosal dissection (ESD) utilizing a novel rigidizing overtube called Pathfinder® Endoscope Overtube (Neptune Medical, Burlingame CA, USA) device in comparison to conventional ESD. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06134687
Study type Interventional
Source Baylor College of Medicine
Contact Michael Mercado, BS
Phone 713-798-3606
Email Michael.Mercado@bcm.edu
Status Not yet recruiting
Phase N/A
Start date May 6, 2024
Completion date July 31, 2025

See also
  Status Clinical Trial Phase
Approved for marketing NCT00094029 - A Treatment Protocol for Patients With Gastrointestinal Stromal Tumor (GIST) Who May Derive Benefit From Treatment With SU011248 N/A
Completed NCT01621295 - Assessing the Patient Experience in Cancer Care N/A
Withdrawn NCT03538613 - Study of People With Metastatic Gastrointestinal Epithelial Cancer Administering Tumor-Infiltrating Lymphocytes in Which the Gene Encoding CISH Was Inactivated Using the CRISPR/Cas9 System Phase 1/Phase 2
Completed NCT02785783 - Endorings™ Assisted Colonoscopy Versus Standard Colonoscopy for Polyp Detection N/A
Completed NCT05172635 - Primary Tumour Response to Induction Chemotherapy in Synchronously Metastasized Colorectal Cancer
Completed NCT01129310 - First Line Study of Irinotecan, Capecitabine and Oxaliplatin in Metastatic Gastric or Gastroesophageal Cancer. Phase 2
Completed NCT03411915 - A Study of XmAb®18087 in Subjects With NET and GIST Phase 1
Completed NCT00052962 - Debulking and Chemotherapy With or Without Intraperitoneal Chemotherapy to Treat Peritoneal Carcinomatosis Phase 3
Recruiting NCT06159634 - Traction vs. No Traction in Colonic ESD N/A
Withdrawn NCT00640692 - Kinase Genotyping of Gastro Intestinal Stomach Tumors (GISTs) From Patients Enrolled in Pfizer A6181112 Phase IIIb Trial
Completed NCT05320029 - Disposable Powered Articulating Linear Cutter Stapler in Gastrointestinal Tissue Cutting and Anastomosis N/A
Completed NCT00465725 - A Study Comparing Oral Picoplatin With Intravenous Picoplatin in Subjects With Solid Tumors Phase 1