Clinical Trials Logo

Clinical Trial Summary

Title of the study: Target weight correction and vascular stiffness in hemodialysis patients Study design: Randomized clinical trial in the study centre at two locations Applied medical device: 1. Body Composition Monitor' (BCM, Fresenius) to measure fluid volume overload. 2. Arteriograph 24 (Tensiomed, Budapest, Hungry) to assess vascular stiffness before, during and after the intervention. Study hypothesis: A protocolized adjustment of target weight guided by bio-impedance spectroscopy will improve fluid status, systolic and diastolic blood pressure, and reduce the arterial wall stiffness without increasing the prevalence of intradialytic hypotension. Aim of the study: 1. To demonstrate improvement in fluid status by a target weight correction protocol which applies BCM measurements. 2. To demonstrate that better fluid volume control is associated with a) improvement in vascular health as assessed by pulse wave velocity and augmentation index and b) reduction in antihypertensive medications use. 3. To show that this approach does not lead to more episodes with intradialytic hypotension. The number of patients: 70 patients


Clinical Trial Description

This study proposal is looking at the application of an accurate assessment of fluid status in hemodialysis (HD) patients to correct fluid overload. Patients undergoing hemodialysis suffer from the inability to maintain their normal body fluids and have a high probability to develop hypertension at initiation of dialysis (1). Long-standing fluid overload is no longer linked solely to high blood pressure, but also to vascular dysfunction and heart failure (1). Fluid overload is estimated based on the amount of fluids available outside the cells (extracellular fluid volume, ECFV). Thus, determination of the right amount of fluid removal during the dialysis depends on the weight of the patient when the ECFV is normal (referred to as Target Weight, TW). Essentially, TW is assessed by routine clinical judgment, for example, leg and hands swelling (edema), elevation in blood pressure and the expansion of the external jugular vein. Unfortunately, this clinical judgment is not reliable to assess fluid status (2, 3); hence, overestimation of TW occurs and leads to fluid overload. Current technology allows assessing fluid overload accurately by using bio-impedance, a non-invasive method that can be easily used in the HD setting. Despite this, very few studies have been reported where a systematic approach was followed to use bio-impedance to correct a TW that has been set too high, with the ultimate goal to correct fluid overload. Therefore, this study aims to provide better fluid control through an intervention to improve fluid status toward normovolemia by using bio-impedance assessment of fluid overload rather than clinical judgments. First, the fluid status will be measured in all study participants by multifrequency bio-impedance using a 'Body Composition Monitor' (BCM, Fresenius). Second, we will divide the study subjects into two groups; the control group which will initially receive standard conventional therapy (no intervention) for 3 months, and the intervention group will undergo by BCM measurements and integrated TW correction protocol for 3 months. Third, after three months, the control group will also involve in the same TW correction adjustment. The Primary outcome is improvement in fluid status towards normovolemia (<1.1 L fluid overload). Secondary outcomes are a) improvement in vascular health as assessed by pulse wave velocity and augmentation index and b) a decrease in the use of antihypertensive medications. Altogether, an optimized fluid status via implemented fluid management plan will provide better control of fluid overload, blood pressure, and improvement in vascular function. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03929471
Study type Interventional
Source University of Alberta
Contact
Status Completed
Phase N/A
Start date September 1, 2019
Completion date July 1, 2020

See also
  Status Clinical Trial Phase
Completed NCT04095143 - Ultrasound Markers of Organ Congestion in Severe Acute Kidney Injury
Terminated NCT03335124 - The Effect of Vitamin C, Thiamine and Hydrocortisone on Clinical Course and Outcome in Patients With Severe Sepsis and Septic Shock Phase 4
Completed NCT05070819 - Atrial Natriuretic Peptide in Assessing Fluid Status N/A
Withdrawn NCT04870073 - Retrograde Autologous Priming and Mannitol for Reducing Hemodilution in Cardiac Surgery Phase 3
Recruiting NCT02989051 - Fluid Restriction Keeps Children Dry Phase 2/Phase 3
Completed NCT00852514 - The Optimization of Blood Pressure and Fluid Status Control With Eight-Polar Bioelectrical Impedance Analysis Phase 4
Completed NCT00517127 - Crystalloids Versus Colloids During Surgery Phase 4
Not yet recruiting NCT05983549 - Neutral Versus Liberal fLuId In Traumatic Brain Injury: a Randomised Controlled Trial N/A
Recruiting NCT06071026 - Hemodynamic Effects of Variations in Net Ultrafiltration Rate During Continuous Renal Replacement Therapy. N/A
Completed NCT02903316 - Predicting Fluid Responsiveness in on Pump Coronary Artery Bypass Graft Using Extra Systoles N/A
Terminated NCT02458157 - Forced Fluid Removal in High Risk Acute Kidney Injury Phase 4
Completed NCT02325856 - Application of Bioimpedance Spectroscopy in Taiwan Dialysis Patients N/A
Completed NCT01628731 - Furosemide Versus Ethacrynic Acid in Children With Congenital Heart Disease Phase 3
Not yet recruiting NCT05647200 - Optimization of Prime Fluid Strategy to Preserve Microcirculatory Perfusion During Cardiac Surgery With Cardiopulmonary Bypass, Part II N/A
Completed NCT03768752 - Diastolic Dysfunction and Interstitial Lung Edema in Septic Patients
Terminated NCT03553394 - Effects of Restrictive Fluid Strategy on Postoperative Oliguric Pancreatic Surgery Patients N/A
Completed NCT06097923 - Implementation of Fluid Strategies Using Real-time Bioelectrical Analyzer in Surgical Intensive Care Unit (SICU) N/A
Recruiting NCT04215692 - Lung Ultrasound-guided Fluid Therapy in Pediatric Intensive Care Unit Patients N/A
Not yet recruiting NCT03322410 - Hydratation Status at Initiation of Peritoneal Dialysis: Study of the Role of Peritoneal Permeability N/A
Completed NCT02679625 - Comparison of Non-Invasive Methods of Assessing Fluid Responsiveness in ED and ICU Patients