Femoral Neck Fractures Clinical Trial
Official title:
Fixation Using Alternative Implants for the Treatment of Hip Fractures: A Multi-Centre Randomized Trial Comparing Sliding Hip Screws and Cancellous Screws on Revision Surgery Rates and Quality of Life in the Treatment of Femoral Neck Fractures
Each year, hip fracture, an injury that can impair independence and quality of life, occurs in about 280,000 Americans and 36,000 Canadians. The annual healthcare costs associated with this injury are expected to soon reach $9.8 billion in the United States and $650 million in Canada. It is important to have in place optimal practice guidelines for the surgical handling of this injury. One type of hip fracture, called a femoral neck fracture, is often treated with a surgical procedure called internal fixation. When performing internal fixation, most orthopaedic surgeons favor using multiple small diameter screws over using a single large diameter screw with a sliding plate. However, use of the sliding hip screw might in fact result in fewer complications after surgery and reduce the need for a second surgery, called a revision surgery. This study will compare the two different surgical procedures to determine which one results in better outcomes after surgery.
One type of hip fracture, called a femoral neck fracture, involves a break in the narrow part
of the femur bone where the head of the femur is joined to the main shaft. The break can be
either undisplaced, which involves very little separation at the fracture site, or displaced,
in which there is substantial separation. Surgeons agree that the best surgical procedure for
an undisplaced fracture is internal fixation, in which a mechanical implant reconnects the
two separated segments of bone. For displaced fractures, surgeons usually choose between
internal fixation and a hip joint replacement.
There is more than one way to perform internal fixation. The majority of orthopaedic surgeons
currently favor the use of multiple small diameter cancellous screws. However, an alternative
method that uses a single large diameter screw attached to a sideplate, called a sliding hip
screw, has been gaining popularity and might reduce post-surgical complications and the need
for revision surgery. Which surgical method is best for the patient is unknown. This study
will compare the use of multiple small diameter cancellous screws versus a single sliding hip
screw on rates of revision surgery 2 years after patients sustain femoral neck fractures and
undergo internal fixation. The study will also compare the impact of the two different
surgical procedures on the overall health, function, and quality of life of patients. Results
from this study may impact current orthopaedic practice.
Participation in this study will last 2 years. Before surgery, participants will complete a
baseline assessment that will include x-rays, a medical history review, and a physical
examination. Participants will then be randomly assigned to undergo one of two types of
internal fixation surgeries for repairing their hip fractures. In one group of participants,
surgeons will use at least two small cancellous threaded screws that have a diameter of at
least 6.5 mm. In the other group of participants, surgeons will use a single large diameter
screw that is partially threaded. This screw, called a sliding hip screw, will be affixed to
the femur bone with a sideplate, and there will be no other fixations. All surgeons, who will
need to meet certain criteria to partake in the study, will follow the manufacturers'
technique guidelines for using either type of screw. Specific aspects of both the
pre-operative and post-operative care, such as the use of antibiotics and calcium
supplementation, will be standardized for all participants.
Follow-up assessments will be completed either by phone or in-person at the hospital or
clinic. They will occur 1, 2, and 10 weeks after surgery and 6, 9, 12, 18, and 24 months
after surgery. All assessments will include questionnaires and interviews on health status,
hip function, pain, and revision surgery. Some of the in-person assessments will also include
x-rays.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05505604 -
PENG vs FICB for Hip Fracture in ED Patients
|
N/A | |
Recruiting |
NCT04462172 -
A Prospective Multicenter Cohort Study About Internal Fixation Using FNS Versus MCS for Femoral Neck Fracture
|
N/A | |
Enrolling by invitation |
NCT04110639 -
Intraoperative Monitoring of Femoral Head Perfusion
|
N/A | |
Terminated |
NCT01908751 -
Fixation Using Alternative Implants for the Treatment of Hip Fractures (FAITH-2)
|
Phase 3 | |
Recruiting |
NCT01934049 -
Postoperative Recovery in Elderly Patients Undergoing Hip Hemi-arthroplasty
|
Phase 4 | |
Recruiting |
NCT01219088 -
Intrathecal Morphine,Femoral Nerve Block,Periarticular Bupivacaine Infiltration for Pain After Intramedullary Hip Screw
|
Phase 4 | |
Not yet recruiting |
NCT00749710 -
Blood Loss and Complications of Internal Fixation of Femoral Neck Fractures in Patients Treated With Clopidogrel
|
N/A | |
Active, not recruiting |
NCT00491673 -
A Prospective Randomized Trial of Uncemented Versus Cemented Hemiarthroplasty for Displaced Femoral Neck Fractures
|
N/A | |
Completed |
NCT00464230 -
Hemiarthroplasty or Internal Fixation for Displaced Femoral Neck Fractures
|
Phase 4 | |
Recruiting |
NCT03966716 -
Hips Screws or (Total) Hip Replacement for Undisplaced Femoral Neck Fractures in Elderly Patients (HipSTHeR)
|
N/A | |
Recruiting |
NCT05227924 -
Safety and Performance Assessment of the SYMBOL Range of Medical Devices in Patients Underlying Total Hip Arthroplasty
|
||
Completed |
NCT03666637 -
Femoral Neck Fracture in Adult and Avascular Necrosis and Nonunion
|
||
Terminated |
NCT03721835 -
Safety Study of Femoral Neck Fracture System
|
N/A | |
Not yet recruiting |
NCT04408053 -
Mini-invasive Preventive Fixation of the Contralateral Femoral Neck in Patients Operated on for a Femoral Neck Fracture
|
Phase 3 | |
Recruiting |
NCT04577261 -
FNS (FEMORAL NECK SYSTEM) Study
|
||
Recruiting |
NCT04589598 -
Femoral Neck System and Multiple Cannulated Screws in Femoral Neck Fracture
|
N/A | |
Not yet recruiting |
NCT06078371 -
Opioid-Free Pain Treatment in Trauma Patients
|
N/A | |
Withdrawn |
NCT02198820 -
Practice Survey on Femoral Neck Fractures and the Incidence of Type of Anesthesia on Patient Outcome
|
N/A | |
Active, not recruiting |
NCT02246335 -
Hemiarthroplasty Compared to Total Hip Arthroplasty for Displaced Femoral Neck Fractures in the Elderly-elderly
|
N/A | |
Not yet recruiting |
NCT00926666 -
A Dose Finding Study for Pain Relief of a Broken Hip
|
Phase 4 |