Clinical Trials Logo

Clinical Trial Summary

Each year, hip fracture, an injury that can impair independence and quality of life, occurs in about 280,000 Americans and 36,000 Canadians. The annual healthcare costs associated with this injury are expected to soon reach $9.8 billion in the United States and $650 million in Canada. It is important to have in place optimal practice guidelines for the surgical handling of this injury. One type of hip fracture, called a femoral neck fracture, is often treated with a surgical procedure called internal fixation. When performing internal fixation, most orthopaedic surgeons favor using multiple small diameter screws over using a single large diameter screw with a sliding plate. However, use of the sliding hip screw might in fact result in fewer complications after surgery and reduce the need for a second surgery, called a revision surgery. This study will compare the two different surgical procedures to determine which one results in better outcomes after surgery.


Clinical Trial Description

One type of hip fracture, called a femoral neck fracture, involves a break in the narrow part of the femur bone where the head of the femur is joined to the main shaft. The break can be either undisplaced, which involves very little separation at the fracture site, or displaced, in which there is substantial separation. Surgeons agree that the best surgical procedure for an undisplaced fracture is internal fixation, in which a mechanical implant reconnects the two separated segments of bone. For displaced fractures, surgeons usually choose between internal fixation and a hip joint replacement.

There is more than one way to perform internal fixation. The majority of orthopaedic surgeons currently favor the use of multiple small diameter cancellous screws. However, an alternative method that uses a single large diameter screw attached to a sideplate, called a sliding hip screw, has been gaining popularity and might reduce post-surgical complications and the need for revision surgery. Which surgical method is best for the patient is unknown. This study will compare the use of multiple small diameter cancellous screws versus a single sliding hip screw on rates of revision surgery 2 years after patients sustain femoral neck fractures and undergo internal fixation. The study will also compare the impact of the two different surgical procedures on the overall health, function, and quality of life of patients. Results from this study may impact current orthopaedic practice.

Participation in this study will last 2 years. Before surgery, participants will complete a baseline assessment that will include x-rays, a medical history review, and a physical examination. Participants will then be randomly assigned to undergo one of two types of internal fixation surgeries for repairing their hip fractures. In one group of participants, surgeons will use at least two small cancellous threaded screws that have a diameter of at least 6.5 mm. In the other group of participants, surgeons will use a single large diameter screw that is partially threaded. This screw, called a sliding hip screw, will be affixed to the femur bone with a sideplate, and there will be no other fixations. All surgeons, who will need to meet certain criteria to partake in the study, will follow the manufacturers' technique guidelines for using either type of screw. Specific aspects of both the pre-operative and post-operative care, such as the use of antibiotics and calcium supplementation, will be standardized for all participants.

Follow-up assessments will be completed either by phone or in-person at the hospital or clinic. They will occur 1, 2, and 10 weeks after surgery and 6, 9, 12, 18, and 24 months after surgery. All assessments will include questionnaires and interviews on health status, hip function, pain, and revision surgery. Some of the in-person assessments will also include x-rays. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT00761813
Study type Interventional
Source University of Minnesota - Clinical and Translational Science Institute
Contact
Status Completed
Phase N/A
Start date March 2009
Completion date March 2016

See also
  Status Clinical Trial Phase
Recruiting NCT05505604 - PENG vs FICB for Hip Fracture in ED Patients N/A
Recruiting NCT04462172 - A Prospective Multicenter Cohort Study About Internal Fixation Using FNS Versus MCS for Femoral Neck Fracture N/A
Enrolling by invitation NCT04110639 - Intraoperative Monitoring of Femoral Head Perfusion N/A
Terminated NCT01908751 - Fixation Using Alternative Implants for the Treatment of Hip Fractures (FAITH-2) Phase 3
Recruiting NCT01934049 - Postoperative Recovery in Elderly Patients Undergoing Hip Hemi-arthroplasty Phase 4
Recruiting NCT01219088 - Intrathecal Morphine,Femoral Nerve Block,Periarticular Bupivacaine Infiltration for Pain After Intramedullary Hip Screw Phase 4
Not yet recruiting NCT00749710 - Blood Loss and Complications of Internal Fixation of Femoral Neck Fractures in Patients Treated With Clopidogrel N/A
Active, not recruiting NCT00491673 - A Prospective Randomized Trial of Uncemented Versus Cemented Hemiarthroplasty for Displaced Femoral Neck Fractures N/A
Completed NCT00464230 - Hemiarthroplasty or Internal Fixation for Displaced Femoral Neck Fractures Phase 4
Recruiting NCT03966716 - Hips Screws or (Total) Hip Replacement for Undisplaced Femoral Neck Fractures in Elderly Patients (HipSTHeR) N/A
Recruiting NCT05227924 - Safety and Performance Assessment of the SYMBOL Range of Medical Devices in Patients Underlying Total Hip Arthroplasty
Completed NCT03666637 - Femoral Neck Fracture in Adult and Avascular Necrosis and Nonunion
Terminated NCT03721835 - Safety Study of Femoral Neck Fracture System N/A
Not yet recruiting NCT04408053 - Mini-invasive Preventive Fixation of the Contralateral Femoral Neck in Patients Operated on for a Femoral Neck Fracture Phase 3
Recruiting NCT04577261 - FNS (FEMORAL NECK SYSTEM) Study
Recruiting NCT04589598 - Femoral Neck System and Multiple Cannulated Screws in Femoral Neck Fracture N/A
Not yet recruiting NCT06078371 - Opioid-Free Pain Treatment in Trauma Patients N/A
Withdrawn NCT02198820 - Practice Survey on Femoral Neck Fractures and the Incidence of Type of Anesthesia on Patient Outcome N/A
Active, not recruiting NCT02246335 - Hemiarthroplasty Compared to Total Hip Arthroplasty for Displaced Femoral Neck Fractures in the Elderly-elderly N/A
Not yet recruiting NCT00926666 - A Dose Finding Study for Pain Relief of a Broken Hip Phase 4