Clinical Trials Logo

Clinical Trial Summary

Comparing with a randomized controlled trial two different feeding systems in two groups of late-preterm newborns for evaluating which is more efficient in promoting the coordination in the process of sucking-swallowing-breathing and better cardiorespiratory stability. The B-ESP group will be fed with a feeding system with a valved ergonomic teat; the B-STD with a standard feeding system.


Clinical Trial Description

The swallowing patterns are still immature in the newborn, especially if preterm. An incomplete synchronization in the process of sucking, swallowing and breathing could lead to some difficulty during feedings with desaturations and risk of milk inhalation in the upper airway tract. Moreover, a dysfunctional or immature pattern of sucking, swallowing and breathing also affect the post-prandial period, tiring the newborn and increasing the cardio-respiratory instability. Breastfeeding promote the development of a physiological coordination of the process of sucking, swallowing and breathing, guaranteeing high and stable values of oxygenation during feedings. On the other hand, bottle-feeding could be responsible of a difficult coordination among the phases of swallowing and breathing. In an healthy, at term, brestfed newborn is observed a typical pattern of sucking-swallowing-expiration with a ratio of 1:1:1. In a bottlefed newborn this ratio is 2-12:1:4, with a relative increase of the period of sucking compared to the swallowing one, that could lead to apnoeas and desaturations. The differences between the two feedings modality are more accentuated in the late-preterm newborn, which is more prone to cardio-respiratory instability compared to the healthy at term newborn, because of the immaturity of the respiratory centers in the brainstem, and of the processes responsible for the coordination of the sucking, swallowing and breathing . However breastfeeding, in spite of the fact that is crucial for the development of the correct process of sucking, can be challenging in the premature infant because it requires a considerable physical effort. Therefore, disposing of devices for nutrition able to facilitate oral feeding, simulating the physiologic breastfeeding, is necessary. In this way, we can contribute to the development of the proper sucking-swallowing-breathing pattern and to improve cardio-respiratory stability. In literature there are multiple studies carried out on term newborns demonstrating the importance of the negative pressure or air vacuum created in the oral cavity, in order to promote the emptying of the lactiferous ducts and/or of the teat and simultaneously promote the maintainance of the right respiratory pattern. An ergonomic feeding system with a valve able to create vacuum could be able to respond to the demands of late preterm newborns. Aim of the study is to evaluate the effects of a trial with an experimental feeding system with a teat with a valve able to facilitate the vacuum in the oral cavity on the pattern of sucking-swallowing and breathing in late preterm newborns. NUMBER OF PATIENTS Precise data regarding swallowing/respiration rate in bottle-fed late preterm infants in the first 3 days of life are lacking in the literature. Considering a mean swallow/respiration ratio of 1.5 and a variance of 0.5, obtained from surveys performed at our center prior to the study, a sample size of 38 infants per arm was estimated to achieve 80% power to detect a 30% difference on the primary outcome with a significance level of 0.05. STUDY DESIGN Late preterm newborns eligible to enter in the study, prior obtaining the informed consent from parents, will be assigned in the "B-ESP" or "B-STD" group through a process of block randomisation, controlled by a software. Newborns included in the randomisation, after a training of 3 meals with the feeding bottle assigned from the randomisation, can be entered in the study. Newborns included in the study will be monitored for the entire duration of a meal and the subsequent 3-hours period. This monitoring will be collected in two different times (T1 and T2): in the second day of life (24-48 hours of life) and in the fourth day of life (72-96 hours of life). The study includes an audio recording of the swallowings through a microphone in the room and the recordings of the process of sucking and swallowing through a cutaneous sensor. In addition, a cardiorespiratory monitoring with a poligraph will be made, considering oxygen saturation, cardiac and respiratory frequency and electrocardiography. The meal's video recording will permit a subsequent classification of the sucking movements and the evaluation of any possible interference in the polygraphic recording. FEEDING DEVICES Newborns of the B-STD group will be fed using a classic disposable feeding device, which is actually in use in our centre and provided by our hospital, composed of: - a 150 mL feeding bottle in polypropylene, devoid of BPA; - a silicon teat, devoid of BPA, available in two types, (a slow graduated flow and a standard flow) depending on the necessities and suction abilities of the baby; - a protective plug. Newborns of the B-ESP group will be fed using a feeding system with a valved ergonomic teat, composed of: - a slow-flow ergonomic silicon teat - polipropilene bottle with a capacity of 150 mL, with a ventilation valve on the bottom - silicon valve Newborns will be fed with defined quantities of maternal milk or bank donated milk, based on weight and gestational age. The meal will be administered by the caregiver (a parent or a nurse) previously trained. The meal's administration will be performed keeping the baby in the caregivers's arms in the ESL position (semielevated side-lying). At the end of the feeding process the newborn will be repositioned in his cradle in the supine position. The cardiosaturimetric evaluation will be performed using a system of polygraphic monitoring, which allows a simultaneous non-invasive recording of cardiorespiratory parameters, noises and movements associated to the sucking and swallowing processes combined to video recordings. The evaluation of the sucking process will be carried out using a structured questionnaire composed by 31 items, which allows to distinguish normal suction (mature) from disorganized and dysfunctional ones. Considering simultaneously the cardiosaturimetric parameters, video, audio and cutaneous sensor's recordings, it is possible to obtain a more accurate evaluation of the processes of swallowing, sucking and breathing of the newborn during meal administration. It is also possible to identify the exact moment of the breathing process assigned to the newborn's swallowing. CLINICAL DATA At birth: - gestational age; - weight in grams; - z-score; - sex; - type of delivery; - peri-partum condition, including possible administration of prenatal corticosteroids; - type of support provided at birth; At T1 and T2: - hours from birth; - weight; - z-score; - number of meals in a day; - type of milk administered; - overall volume administered expressed in mL in a day; - duration of a meal expressed in minutes; - number of regurgitation or vomit during the administration of a meal; - number of regurgitation or vomit after the admninistration of a meal; At discharge: - weight; - z-score; - number of meals in a day; - type of feeding (exclusive breastfeeding; exckusive bottlefeeding or mixed) - overall volume administered expressed in mL in a day; INSTRUMENTAL DATA - Number of suctions; - Number of swallowings; - Number of apnoeas; - Average duration of apnoeas; - Number of oxygen desaturations - Minimal oxygen saturation; - Number of reduction of cardiac frequency (bradycardia); - Minimal cardiac frequency. The definition of apnoea, oxygen desaturation and bradycardia applied in this study are the ones defined by literature (Di Fiore JM, Arko MK, Miller MJ, et al. Cardiorespiratory Events in Preterm Infants Referred for Apnea Monitoring Studies. PEDIATRICS. 2001;108(6):1304-1308.) - APNOEA: arrest of the breathing acts for a period of at least 20 seconds or arrest of the breathing acts for a period of at least 5 seconds associated with bradycardia and/or desaturations; - OXYGEN DESATURATIONS: reduction of the oxygen saturation (SpO2) <80% or of at least 5% compared to the baseline, for at least 4 seconds. - BRADYCARDIA: reduction of the cardiac frequency under 80 bpm for at least 4 seconds STATISTICAL ANALYSIS Statistical analysis will be carried out using the STATISTICA software package for Windows (StatSoft, Inc., Tulsa, Oklahoma, USA). Every newborn in the experimental group will be matched with a newborn of the control group similar for gestational age and weight. For the normal distribution, data will be tested with the Kolmogorov-Smirnov test and with the exploratory data analysis. Data will be expressed as statistical mean and standard deviation (SD) or as median and interquantile range depending on the relative distribution. The differences between the polisonnographic data will be evaluated with the Student's T test or through a similar non-parametric test depending on the distribution: Fisher test for comparison between categorical data and regression tests (linear and non-linear) for comparison between continuous variables. Statistical significance is set as p<0.05. EXPECTED RESULTS The more physiological administration of milk with a feeding system with a valved ergonomic teat, could better promote the development of coordination in the process of sucking-swallowing-breathing. Therefore inhalation and cardiosaturimetric events during a meal and immediately after will be reduced and therefore the newborn's oral feeding tolerance will increase, making it more similar to physiological breastfeeding. Bottle-feeding milk administration with a feeding system with a valved ergonomic teat in the first days of life, the period when exclusive breastfeeding is more difficult, could also promote the transition between bottle-feeding to breastfeeding, because this mechanism is more similar to the physiological one. If the results of this study will support this hypotesis, feeding system with a valved ergonomic teat could be chosen as a non-pharmacological treatment for late-preterm newborns who encounter difficulty in the oral feeding, such as cardio-respiratory instability during the sucking process and risk of milk inhalation when the breastfeeding is not possible. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04400175
Study type Interventional
Source University of Turin, Italy
Contact
Status Completed
Phase N/A
Start date December 1, 2020
Completion date May 31, 2023

See also
  Status Clinical Trial Phase
Active, not recruiting NCT05048550 - Babies in Glasses; a Feasibility Study. N/A
Active, not recruiting NCT03655639 - Local Version of the Multi-center PREVENT Study Evaluating Cardio-respiratory Instability in Premature Infants
Enrolling by invitation NCT05542108 - Adding Motion to Contact: A New Model for Low-cost Family Centered Very-early Onset Intervention in Very Preterm-born Infants N/A
Completed NCT03680157 - Comparing Rater Reliability of Familiar Practitioners to Blinded Coders
Completed NCT03337659 - A Cluster Randomized Controlled Trial of FICare at 18 Months N/A
Completed NCT03649932 - Enteral L Citrulline Supplementation in Preterm Infants - Safety, Efficacy and Dosing Phase 1
Completed NCT03251729 - Cerclage On LOw Risk Singletons: Cervical Cerclage for Prevention of Spontaneous Preterm Birth in Low Risk Singleton Pregnancies With Short Cervix Phase 4
Not yet recruiting NCT05039918 - Neonatal Experience of Social Touch N/A
Not yet recruiting NCT03418311 - Cervical Pessary Treatment for Prevention of s PTB in Twin Pregnancies on Children`s Long-Term Outcome N/A
Not yet recruiting NCT03418012 - Prevention of sPTB With Early Cervical Pessary Treatment in Women at High Risk for PTB N/A
Completed NCT02913495 - Vaginal Versus Intramuscular Progesterone for the Prevention of Recurrent Preterm Birth Phase 4
Completed NCT02952950 - Is it Possible to Prolong the Duration of Breastfeeding in Premature Infants? a Prospectivt Study N/A
Not yet recruiting NCT02880696 - Perception of Temporal Regularity in Tactile Stimulation: a Diffuse Correlation Spectroscopy Study in Preterm Neonates N/A
Completed NCT02743572 - Iron-fortified Parenteral Nutrition in the Prevention and Treatment of Anemia in Premature Infants N/A
Completed NCT02661360 - Effects of Swaddling on Infants During Feeding N/A
Completed NCT02879799 - Family Integrated Care (FICare) in Level II NICUs N/A
Completed NCT01352234 - Comparison of Doses of Acetylsalicylic Acid in Women With Previous History of Preeclampsia Phase 4
Completed NCT01163188 - Social Adjustment and Quality of Life After Very Preterm Birth N/A
Terminated NCT00675753 - Three Interacting Single Nucleotide Polymorphisms (SNPs) and the Risk of Preterm Birth in Black Families N/A
Terminated NCT00179972 - Evaluation of Pulse Oximetry Sensors in Neonates N/A