Outpatient polyp treatment can be performed in a few different ways but generally involves passing a special type of hysteroscope (3-6 millimetre in diameter) into the womb through which specifically designed miniature operating instruments are passed to remove the polyp(s). At present the most commonly used instruments use an electrical cutting edge. However, a new instrument using a mechanical cutting edge has come to market. In patients having a general anaesthesia the mechanical cutting instrument has been shown to be easier to learn, more effective at completely removing polyps and quicker. However, the instrument is slightly larger, which could potentially cause more discomfort and prolong the procedure in the outpatient setting. Therefore, the investigators want to compare the electrical and mechanical instruments for speed, completeness of polyp removal and patient acceptability.


Clinical Trial Description

The miniaturisation of hysteroscopes and ancillary instrumentation coupled with enhanced visualisation has enabled hysteroscopic surgery to be performed in an outpatient setting without the need for general anaesthesia or inpatient hospital admission. The most common operative hysteroscopic procedure is endometrial polypectomy and the feasibility and acceptability of such approaches has been demonstrated. The procedure involves removing polyps from the uterine cavity. Over 90% of UK gynaecologists routinely recommend removal of endometrial polyps following diagnosis with the aim of treating associated symptoms of abnormal bleeding and retrieving the specimen to exclude malignant or pre-malignant disease. The investigators have recently completed recruitment to a large, multicentre, randomised control trial called the Outpatient Polypectomy Trial ('OPT' http://www.opt.bham.ac.uk, ISRCTN65868569), which has compared treatment settings for the removal of endometrial polyps. Over 500 women were randomised between outpatient procedures and day-case procedures which require a general anaesthetic. The analysis regarding relative treatment effectiveness will be available in late 2012. Interestingly, this trial also recruited women who expressed a preference for treatment setting. This resulted in an additional 400 women entering the study of which over 90% had a preference for an outpatient setting (Personal communication Clark TJ).

Thus outpatient removal of polyps is, feasible, safe and preferred by women. The majority of gynaecologists performing outpatient procedures, cut polyps away from their attachment to the uterine wall using a miniature bipolar electrosurgical instrument; Versapoint® (Gynecare; Ethicon Inc., New Jersey, USA). This procedure is carried out under direct hysteroscopic vision, without the need for routine, potentially painful, dilatation of the cervix. Whilst the technology is feasible and effective it requires skill and experience in outpatient hysteroscopic surgery, which many UK gynaecologists lack and this is reflected in the limited adoption of outpatient procedures in spite of evidence supporting their use. Moreover, even for the experienced operator, retrieving the removed polyp specimen from the uterine cavity, to send off for histopathological assessment, can be a challenge due to the small operating field and the need to negotiate the narrower endocervical canal. Various methods are used to retrieve specimens and include the use of mechanical instruments (e.g. grasping forceps or snares) which do not require the cervix to be dilated. However, this approach often fails because of the fragility of these minute hysteroscopic instruments (diameter 1.2-1.8mm) so recourse to insertion of larger 'polyp' forceps blindly into the uterine cavity is necessary. The latter approach requires the use of local injection of anaesthetic into the cervix which is uncomfortable and dilatation of the cervix with the potential for uterine trauma.

Since, completion of recruitment of OPT trial a new technology has become available called the TRUCLEAR hysteroscopic morcellator (Smith&Nephew, Andover MASS, USA). This technology incorporates a 4mm disposable mechanical cutting device which simultaneously cuts and aspirates polyp tissue. The ability to both cut and retrieve polyps avoids the need for additional instrumentation of the uterine cavity in order to retrieve the detached polyp specimen i.e. a single insertion of the hysteroscope is required only. The use of mechanical morcellation may also improve visualisation during surgery by avoidance of bubble formation or the production of tissue fragments ('chips') associated with the electrosurgical approach. Thus, this new technology has potential advantages for the patient (acceptability, pain, infection, safety), the surgeon (speed, feasibility, completeness of the procedure) and health service (avoidance of second stage procedures under general anaesthetic). However, the established single use bipolar electrode is smaller than the disposable morcellator cutting device (1.6mm vs. 2.9mm). Moreover, the bipolar electrode can be used down the operating channel of a variety of continuous flow hysteroscopes which are longer and smaller in diameter and in day-to-day use in gynaecological practice in outpatient settings (outer diameter 4.1mm (Gynecare; Ethicon Inc., New Jersey, USA), 5mm Storz Bettocci hysteroscope (Karl Storz Endoscopy-America inc., California, USA) or Olympus 5.5mm (Olympus Corporation, Shinjuku-ku, Tokyo, Japan). In contrast, the hysteroscopic morcellator system is larger (5.6mm outer diameter) and requires acquisition of specific hysteroscopes with an offset proximal eyepiece to allow the rigid mechanical cutting device to be inserted in direct alignment with the barrel of the hysteroscope. Thus in an outpatient setting, the bipolar electrode may have advantages over the larger hysteroscopic morcellator in terms of ease of uterine instrumentation.

In view of the development of hysteroscopic morcellation and potential advantages associated with this innovation in hysteroscopic instrumentation, the investigators believe that there is an urgent need to undertake a robust health technology assessment. It is timely to perform an RCT now before the findings of the OPT trial are available (which will recommend outpatient as opposed to day-case treatment if increased cost-effectiveness is demonstrated). If the morcellator is considered an easier technology to use by gynaecologists (i.e. less operator skill required), then there is a danger that it will become widely adopted for outpatient use without supporting evidence of benefit. ;


Study Design

Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind (Subject), Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT01509313
Study type Interventional
Source Birmingham Women's NHS Foundation Trust
Contact
Status Completed
Phase Phase 3
Start date June 2012
Completion date June 2013

See also
  Status Clinical Trial Phase
Recruiting NCT05049395 - HFNO Reducing the Incidence of Hypoxia for Hysteroscopy Sedated With Propofol N/A
Completed NCT02472197 - Morcellator Versus Resectoscope in the Treatment of Uterine Polyps by Hysteroscopy N/A
Completed NCT02520414 - Symphion® System In-Office Study N/A
Completed NCT02126397 - Comparative Study of Endometrial Polypectomy Performed With Bipolar Electrode Versapoint and Laser Diode. A Randomised Controlled Trial. N/A
Not yet recruiting NCT02590666 - Endometrial Polypectomy Performed With Bipolar Electrode Versapoint vs Microscissors or Graspers N/A