Clinical Trials Logo

Clinical Trial Summary

The purpose of the study is to compare two different types of imaging techniques to identify endoleaks. Following the endovascular procedure, subjects are seen at one month to have computed tomographic angiography (CTA) to confirm the graft is not leaking (endoleak). CTA is the standard imaging technique used to identify endoleaks. This study will investigate if the image technique color duplex ultrasound with contrast enhanced ultrasound (CEUS) is a good tool to identify endoleaks too.


Clinical Trial Description

Background:

Abdominal aortic aneurysms (AAAs) continue to be a leading cause of death in older age groups. In the 60-85 year-old population, AAA represents the 14th-leading cause of death. Federal funding through Medicare has been allocated for early detection using abdominal ultrasound screening programs. Despite these more aggressive screening programs and concerted efforts by surgeons for timely repair, the incidence of ruptured AAA has continued to increase.

Endovascular aneurysm repair (EVAR) has been the most common type of repair since 2006. Multiple studies reflecting decreased perioperative morbidity and mortality over open repair make this an attractive option for patients. EVAR requires more intensive follow-up than standard open surgical repair, however. Secondary interventions are more common to maintain "seal" of the endograft within the aorta and subsequent exclusion of the aneurysmal component.

The term endoleak is specific to EVAR, and describes the primary means by which endografts fail. Type I endoleaks occur because of inadequate graft seal proximally or distally, resulting in perigraft flow and aneurysm sac pressurization. Type II endoleaks occur when branch arteries arising from the aneurysmal aorta back-bleed into the aneurysm sac due to collateral flow. Type III endoleaks occur when flow persists between segments of a modular graft. Type IV endoleaks occur when flow persists through endograft material (graft porosity). Type V endoleaks have also been called "endotension", and occur when pressurization of the sac occurs in the absence of any demonstrable endoleak. Type I and Type III endoleaks are most concerning for rupture, although persistent Type II endoleaks can also lead to aneurysm rupture and premature death.

The most common method of EVAR follow-up is computed tomographic angiography (CTA). These studies allow accurate measurement of aneurysm sac diameters and volumes. They also are highly sensitive and specific for endoleaks. Type II endoleaks are treated if they remain persistent and are present in the setting of aneurysm sac enlargement. Type I and III endoleaks are immediately treated when identified. Type IV endoleaks are rarely seen with current endograft technology.

Study Objectives:

The purpose of the current study is to compare routine postoperative surveillance by CTA with color duplex ultrasound and contrast enhanced ultrasound (CEUS) for the detection of endoleaks.

Study Design

This is a pilot study comparing the imaging techniques of CTA to CEUS in 25 patients undergoing EVAR at their one month post endograft surveillance. The one month standard follow-up will be used for comparing techniques as this will yield the highest number of endoleak positive patients. Patients will complete a color duplex examination in conjunction with CEUS using the FDA approved ultrasound contrast agent OptisonTM (Perflutren Protein Type A Microspheres for Injection, USP). Following ultrasonographic evaluation, study patients will undergo routine CTA.

Eligible subjects will be asked to participate in the trial following post-op day number 1 from their endovascular procedure. Study participation is ~30 days (+ 7 days). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01230684
Study type Interventional
Source University of Michigan
Contact
Status Terminated
Phase N/A
Start date December 2010
Completion date November 2011