Edentulous Mouth Clinical Trial
Official title:
A Comparative Clinical Study Between the Technique of Border Molding in Complete Dentures Using Light-Cured Acrylic Resin and the Conventional Technique
Verified date | April 2021 |
Source | Hama University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Since the teeth loss leads to disability & impairment, and teeth restoration lead to improvement in the life quality throughout the oral health improvement. The acceptable function of a complete denture on great extent depends on impression technique which includes the maximum coverage of denture supporting areas and making a combination of managing movable soft tissues along with different kinds of impression materials and techniques for accurate reproduction of oral foundation. Border molding considered to be as an important step in the in complete denture fabrication, since the retention of complete dentures depend on several factors, as the biological, physical and mechanical, these factors could be achieved by mean of an accurate border molding followed by an accurate final impression. The border molding technique is the shaping of the border areas of a custom impression tray by manual or functional manipulation of the tissue adjacent to the borders in order to duplicate the size and contour of the vestibule resulting in maintains of the peripheral seal during function. This property causes the border molding process to require twenty-four insertions, namely eight in the maxilla and sixteen in the mandible causing long working time and discomfort in patients. Hence, the material used for this technique should provide optimum working time, have adequate body, and permit the correction of border moulding by additions. However additions if made to a single step border moulded material would again introduce all the disadvantages that are associated with sectional moulding Single-step border molding is considerably more straightforward than sectional border molding owing to the reduced number of tray insertions. This technique is usually used with elastomeric impression materials, which may not provide sufficient time to mold and record the peripheral tissues of the denture bearing area. The present technique uses light polymerizing tray material for molding tray borders, offering extended working time. This is advantageous for operators with less experience, such as dental school students. Furthermore, correction of border molding is possible with the addition of new material. The technique uses materials that are readily available,and no special armamentarium is required.
Status | Completed |
Enrollment | 20 |
Est. completion date | January 1, 2022 |
Est. primary completion date | December 1, 2021 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 45 Years to 75 Years |
Eligibility | Inclusion Criteria: - Well-formed edentulous arch (well-rounded, adequate width and height) Exclusion Criteria: - Patients with undercuts Excessive ridge resorption Flabby anterior ridge Papillary hyperplasia Poor neuromuscular control. Patients having signs of inflammation, ulceration or hyperplasia |
Country | Name | City | State |
---|---|---|---|
Syrian Arab Republic | Removable prosthodontic Department -Hama University-Syria | Hama |
Lead Sponsor | Collaborator |
---|---|
Hama University |
Syrian Arab Republic,
AlHelal A, AlRumaih HS, Kattadiyil MT, Baba NZ, Goodacre CJ. Comparison of retention between maxillary milled and conventional denture bases: A clinical study. J Prosthet Dent. 2017 Feb;117(2):233-238. doi: 10.1016/j.prosdent.2016.08.007. Epub 2016 Oct 17. — View Citation
Aliotta S. The basics of research. Case Manager. 2003 Jul-Aug;14(4):50-1, 70. — View Citation
Liang XH, Kim YM, Cho IH. Residual bone height measured by panoramic radiography in older edentulous Korean patients. J Adv Prosthodont. 2014 Feb;6(1):53-9. doi: 10.4047/jap.2014.6.1.53. Epub 2014 Feb 14. — View Citation
Pawar RS, Kulkarni RS, Raipure PE. A modified technique for single-step border molding. J Prosthet Dent. 2018 Nov;120(5):654-657. doi: 10.1016/j.prosdent.2017.12.020. Epub 2018 Jul 14. — View Citation
Rutkunas V, Ignatovic J. A technique to splint and verify the accuracy of implant impression copings with light-polymerizing acrylic resin. J Prosthet Dent. 2014 Mar;111(3):254-6. doi: 10.1016/j.prosdent.2013.08.015. Epub 2014 Jan 17. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Retention | by using a digital force gauge. | Immediately after Delivery Denture |
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT04984499 -
In Vivo Clinical Investigation of the Safety and Performance of Dental Implants TBR® Tissue Level Z1
|
||
Completed |
NCT01411683 -
Mandibular Overdentures Retained by Conventional or Mini Implants
|
N/A | |
Not yet recruiting |
NCT06458738 -
Clinical Evaluation of a New Printable Denture Base Material
|
N/A | |
Completed |
NCT01230320 -
Simplified vs. Conventional Methods for Complete Denture Fabrication
|
N/A | |
Completed |
NCT05614635 -
Safety and Technical Performance of Plastalgin and Plastalgin Fast in Patients Requiring a Dental Impression
|
||
Active, not recruiting |
NCT05599269 -
Retrospective Clinical Evaluation of Nano-hybrid-composite Denture Teeth
|
N/A | |
Not yet recruiting |
NCT03674554 -
Prosthetic Complications of Screw Retained Restoration
|
N/A | |
Not yet recruiting |
NCT06155630 -
3D Printing for the Fabrication of Mandibular Implant Overdentures
|
N/A | |
Active, not recruiting |
NCT02117856 -
Complete Lower Dentures on 1 or 2 Implants
|
N/A | |
Not yet recruiting |
NCT06393582 -
Accuracy Evaluation of Implant Impressions: A Prospective Study
|
N/A | |
Recruiting |
NCT05375045 -
Real-life Evaluation of the Safety and Performance of EUROTEKNIKA Dental Implants
|
||
Recruiting |
NCT06255522 -
Clinical and Anatomical Factors Influencing Accuracy in Fully Guided Implant Placement.
|
N/A | |
Completed |
NCT04760457 -
Mandibular Overdentures Retained by Mini Implants: a Clinical Trial Comparing Different Surgical and Loading Protocols
|
N/A | |
Completed |
NCT03126942 -
Single-implant Overdentures Retained by the Novaloc Attachment System
|
N/A | |
Enrolling by invitation |
NCT05441527 -
Use of Two Dissolvable Therapeutics Under Removable Partial Dentures
|
N/A | |
Completed |
NCT03056976 -
Cost-effectiveness of Implant Treatment for the Edentulous Mandible
|
N/A | |
Completed |
NCT04475913 -
Digital vs Analog Impression in Cases of All-on-4 - Prosthesis
|
N/A | |
Recruiting |
NCT03536468 -
Psychological Impact of Tooth Loss
|
||
Completed |
NCT03048812 -
Attachment Types for Single-implant Mandibular Overdentures: a Crossover Clinical Trial
|
N/A | |
Recruiting |
NCT02339194 -
Application of a Simplified Method of Complete Denture Fabrication for Severely Resorbed Mandibular Ridges
|
Phase 3 |