Clinical Trials Logo

Clinical Trial Summary

The importance of the stability of hard and soft tissues has been shown to be of paramount importance for long-term implant success. To reach optimal functional and aesthetic outcomes, implant placement must be planned accordingly to prosthetic needs and design. Prosthetically driven implant placement is based on a diagnostic prosthetic set-up that is followed by precise implant planification and placement using CBCT and intraoral scanning. The aim of this research is to evaluate how the clinical and anatomical factors can influence the 3D position of guided surgery.


Clinical Trial Description

After assessing the fulfillment of the inclusion criteria, pre-operative cone beam computed tomography (CBCT) (Newtom, Cefla S.C.) and intraoral digital impressions (Trios®, 3Shape Dental Systems, Denmark) will be obtained for each patient to achieve a digital wax-up and a presurgical plan for the exact position of the implants by a single calibrated operator (RP). Every patient could have a maximum of four implants to be placed (one per quadrant), in those cases, each implant will be placed with its own surgical guide. The digital imaging and communications in medicine (DICOM) files will be imported to a guided-surgery planning software (Codiagnostix, Dental wings) to perform an implant planning based on the digital wax up; in this step the assessment of the mucosal thickness will be performed using the STL and the DICOM files superimposed. The measurement will be taken from the crestal bone until the soft tissue surface (mm). Furthermore, a surgical guide will be designed, and 3D printed (SprintRay Pro S; SprintRay Inc) with implant guide resin (SprintRay EU Surgical Guide Clear; SprintRay Inc) by RP for the surgical procedure, supported by the whole dental arch, and reinforced with one bar across the arch. Through guided surgery, previously planned and designed based on CBCT study and CAD/CAM scanning, placement of Conelog Progressive line implants (Biohorizons Camlog, Iberia) will be performed in maxilla or mandibula in a one stage surgery by a 8 years' experience operator (GB). Implant placement will be fully guided and a postoperative CBCT in ECO mode (35μSv) will be taken after the implant placement to assess the final position. Both CBCT will be aligned (pre-op scan and post-op scan) to make calculations by a single evaluator (AB) included the following: (1) angle: angle deviation measured in degrees; (2) base: deviation at implant shoulder in millimeters; (3) tip: deviation at implant apex in millimeters; (4) 3D offset: global deviation in 3D directions in millimeters; (5) mesiodistal deviation in millimeters: (+) deviated to the distal direction and (-) deviated to the mesial direction; (6) buccolingual deviation in millimeters: direction: (+) deviated to lingual direction and (-) deviated to buccal direction; and (7) apicocoronally deviation in millimeters: direction: ( +) deviated in the apical direction. and (-) deviated in the coronal direction. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06255522
Study type Interventional
Source Universitat Internacional de Catalunya
Contact Marta Valles, DDS, MSc, PhD
Phone +34619747903
Email mvalles@uic.es
Status Recruiting
Phase N/A
Start date March 1, 2024
Completion date September 30, 2024

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04984499 - In Vivo Clinical Investigation of the Safety and Performance of Dental Implants TBR® Tissue Level Z1
Completed NCT01411683 - Mandibular Overdentures Retained by Conventional or Mini Implants N/A
Completed NCT04853459 - A Technique for Border Molding in Complete Dentures Using Light-Cured N/A
Completed NCT01230320 - Simplified vs. Conventional Methods for Complete Denture Fabrication N/A
Completed NCT05614635 - Safety and Technical Performance of Plastalgin and Plastalgin Fast in Patients Requiring a Dental Impression
Active, not recruiting NCT05599269 - Retrospective Clinical Evaluation of Nano-hybrid-composite Denture Teeth N/A
Not yet recruiting NCT03674554 - Prosthetic Complications of Screw Retained Restoration N/A
Not yet recruiting NCT06155630 - 3D Printing for the Fabrication of Mandibular Implant Overdentures N/A
Active, not recruiting NCT02117856 - Complete Lower Dentures on 1 or 2 Implants N/A
Not yet recruiting NCT06393582 - Accuracy Evaluation of Implant Impressions: A Prospective Study N/A
Recruiting NCT05375045 - Real-life Evaluation of the Safety and Performance of EUROTEKNIKA Dental Implants
Completed NCT04760457 - Mandibular Overdentures Retained by Mini Implants: a Clinical Trial Comparing Different Surgical and Loading Protocols N/A
Completed NCT03126942 - Single-implant Overdentures Retained by the Novaloc Attachment System N/A
Enrolling by invitation NCT05441527 - Use of Two Dissolvable Therapeutics Under Removable Partial Dentures N/A
Completed NCT03056976 - Cost-effectiveness of Implant Treatment for the Edentulous Mandible N/A
Completed NCT04475913 - Digital vs Analog Impression in Cases of All-on-4 - Prosthesis N/A
Recruiting NCT03536468 - Psychological Impact of Tooth Loss
Completed NCT03048812 - Attachment Types for Single-implant Mandibular Overdentures: a Crossover Clinical Trial N/A
Recruiting NCT02339194 - Application of a Simplified Method of Complete Denture Fabrication for Severely Resorbed Mandibular Ridges Phase 3
Completed NCT04366895 - 3D -Printed Single Implant Overdentures N/A