Clinical Trials Logo

Clinical Trial Summary

The investigators overall study objective is to determine the difference in outcomes for patients over 60 years of age with a displaced distal femur fracture treated with dual distal femur implants (dual plate or IMN/plate) vs. a single distal femur implant (plate or IMN).


Clinical Trial Description

The incidence of distal femur fractures in elderly patients continues to increase, most recently having an incidence of 8.7/100,000/year. This trend likely accompanies the aging population and the increased rates of knee arthroplasty. While these fractures are far less common than geriatric hip fractures, distal femur fractures present similar treatment challenges. Elderly distal femur fractures tend to occur in compromised hosts with poor bone mineral density. Similar to geriatric hip fractures, care emphasizes early mobilization to avoid the complications associated recumbency, including pneumonia, pressure sores, and venous thromboembolism. These patients are often unable to mobilize with restricted weight bearing, which places significant stress on the fixation construct. As a result, elderly patients with distal femur fractures can have high rates of morbidity and mortality. Despite several prior studies reporting one year mortality greater than 20%, elderly distal femur fractures do not receive the same attention as geriatric hip fractures. These patient injuries are likely similar in terms of their age and comorbidities while having the same issues with post-operative mobility. Therefore, it makes sense that geriatric distal femur fracture patients and geriatric hip fracture patients have similar mortality rates. Investigators recently reported significantly greater in-hospital mortality in geriatric distal femur fractures as compared to geriatric hip fractures. A recent study of the US Medicare database is the largest study on geriatric distal femur fractures in the literature, and the overall mortality of 18.5% is similar to several prior studies ranging from 13-38%. Distal femur fractures have traditionally been treated with operative fixation using either a lateral plate or an intramedullary nail. Advances in plate and nail technology allow for distal femur fractures to be stabilized with minimal soft tissue dissection. While recent studies suggest that early weight bearing can be tolerated with low failure rates, many surgeons continue to institute weight-bearing restrictions for osteopenic patients treated with operative fixation. Nonunion rates for operatively treated distal femur fractures have been reported to be as high as 20% in large series, leading to additional surgery to achieve union. These limitations with operative fixation have led surgeons to investigate the utility of supplementing the fixation with additional plates and/or nails. Since many surgeons may not allow early weight bearing in osteopenic patients with operatively treated distal femur fractures, dual plating of the distal femur and locked plate/IMN combinations have become increasingly popular. Biomechanical studies have demonstrated increased torsional stiffness and axial stiffness in dual plate and plate/nail constructs as compared to single implant. A recent meta-analysis by other investigators has further demonstrated dual implants for distal femur fractures to have a low complication rate (5% nonunion) as compared to prior evidence of single implant fixation (0-25% nonunion). In the recent study, authors reported a trend toward less one year mortality in patients treated with distal femoral replacement (DFR) (13.8%) as compared to operative fixation (22.6%) despite finding similar mortality rates at 90 days post-operatively. Since the complication rate was significantly greater in the DFR cohort, this one year mortality benefit is presumably related to early patient weight bearing after DFR that may not be permitted as frequently with operative fixation. Additionally, patients with a DFR may achieve more early mobility than operatively treated patients who are permitted immediate weight bearing due to enhanced stability in the DFR construct. Using dual implants to treat distal femur fractures may allow patients to achieve early mobility and similar mortality as a DFR patients, but have fewer post-surgical complications and less cost than a DFR. The investigators overall study aim is to determine the difference in outcomes for patients over 60 years of age with a displaced distal femur fracture treated with dual distal femur implants (dual plate or IMN/plate) vs. a single distal femur implant (plate or IMN). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05292313
Study type Interventional
Source University of Utah
Contact
Status Enrolling by invitation
Phase N/A
Start date February 10, 2022
Completion date February 2025

See also
  Status Clinical Trial Phase
Not yet recruiting NCT06078371 - Opioid-Free Pain Treatment in Trauma Patients N/A
Recruiting NCT04076735 - DIFFIR - Geriatric Distal Femur Fixation Versus Replacement N/A
Recruiting NCT04748016 - 3D-printed Bone Models in Addition to CT Imaging for Intra-articular Fracture Repair N/A
Recruiting NCT06028971 - Safety and Performance of the Biphasic Plate Distal Femur: A Multicenter Case Series
Withdrawn NCT03864367 - Mobile Weight-Support Therapy (MWeST) for Mobility After Geriatric Fracture
Active, not recruiting NCT01766648 - Far Cortical Locking Versus Standard Constructs for Distal Femur Fractures N/A
Active, not recruiting NCT04008940 - Locking Plates for Distal Femur Fractures - a Multicenter Case Review
Completed NCT03562364 - Early Advanced Weight Bearing for Peri-articular Knee and Pilon Injuries N/A
Recruiting NCT05805774 - pDIFFIR: Geriatric Periprosthetic DIstal Femur: FIxation Versus Replacement N/A
Completed NCT05363943 - DP Vs DFR for Management of Geriatric Distal Femur Fractures. N/A
Recruiting NCT05792189 - Distal Femur Fx: ORIF(Open Reduction and Internal Fixation) vs DFR (Distal Femur Replacement Total Knee Arthroplasty) N/A