Clinical Trials Logo

Clinical Trial Summary

Dialysis-related amyloidosis (DRA) is a serious complication of long-term hemodialysis (HD). Its pathogenic mechanism involves accumulation of β2-microglobulin (β2M) in the blood. β2M is produced by most cells in the body and is metabolized in the kidney in healthy individuals. However, in HD patients with renal dysfunction, β2M which is not removed entirely by HD accumulates excessively in the blood. Then it forms amyloid fibrils that are deposited in bones, joints, and soft tissues. The fibrils are further modified by advanced glycation end products (AGE), inducing local macrophage infiltration and production of cytokines leading to chronic inflammation and activation of osteoclasts. Consequently, severe complications with various symptoms are developed, which are collectively referred to as DRA. Lixelle® is a whole-blood β2M apheresis column developed to adsorb and eliminate β2M selectively from the blood of DRA patients. The treatment is performed with Lixelle® connected upstream of the dialyzer in series on a HD circuit in every session. The Lixelle® column contains porous cellulose beads with covalently linked hexadecyl alkyl chain ligands, which selectively adsorb β2M, via a molecular sieving effect because of its porous structure and hydrophobic interaction with ligands. Lixelle® has been used to relieve symptoms and prevent the progression of DRA in Japan since 1996, when health insurance coverage and reimbursement for the treatment were approved by Japanese Ministry of Health, Labor, and Welfare. Improvement of the activities of daily living (ADL) and remission of arthralgia by Lixelle® treatment has been shown in several clinical studies.


Clinical Trial Description

In a post-market study on Lixelle® conducted between 1994 and 1997 in Japan, all adverse events in 183 patients (13, 476 treatments) at 58 centers were collected. The most frequent adverse events were temporary hypotension and anemia, which are common in dialysis or any extracorporeal therapy. Since the maximum blood flow rate for Lixelle® is less than the average blood flow rate for the conventional HD in the USA, Lixelle®- treatment requires a longer treatment time to achieve the same Kt/V urea as the conventional HD in the United States. However, the longer dialysis time and the lower blood flow rate are not likely to increase the rate of adverse events. Adverse events (including Serious Adverse Events) will be collected at each treatment whenever they occur and will be analyzed using descriptive statistics. This is a prospective double-armed study of 2 years of Lixelle®-treatment. The study consists of the study arm of 2 years of Lixelle®-treatment in 30 DRA patients and the natural history arm of 2 years of conventional HD in 10 DRA patients as the descriptive reference. The primary objective of this study is to assess the safety of Lixelle® in patients in the USA. The secondary objectives of this study are to assess the probable benefit of Lixelle® to increase the β2M reduction rate in a single dialysis session. Exploratory endpoints are to assess: 1. the changes of DRA symptoms and ADL of the patients treated with Lixelle® using DRAQ (Dialysis-Related Amyloidosis Questionnaire) 2. the changes of QOL of the patients treated with Lixelle® using KDQOL-SF (Kidney Disease Quality of Life Short Form) 3. the pre-treatment β2M levels at baseline, one and two years; and 4. bone cysts at baseline and two years ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02952144
Study type Interventional
Source Kaneka Medical America LLC
Contact Joanne McLaughlin
Phone (646) 202-3566
Email joanne.mclaughlin@kaneka.com
Status Recruiting
Phase N/A
Start date October 2015
Completion date December 2024

See also
  Status Clinical Trial Phase
Completed NCT03211676 - Comparison of Hemodialysis With Medium Cut-off Dialyzer (Theranova) and High Flux Dialyzer N/A
Completed NCT02064153 - Studying the Effect of Dialysate Temperature on Toxin Removal and Hypotension N/A
Completed NCT04160351 - A Randomised, Open-Label, Cross Over Group, Single-Centre Controlled Study To Evaluate The Clinical Performance Of Medium Cut-Off Membrane Dialyser Compared With High Flux Dialyser Among Patients With Chronic Haemodialysis N/A