Clinical Trials Logo

Clinical Trial Summary

Insulclock® is a small electronic device developed to facilitate the optimal administration of insulin. This device works as an add-on module of commercially available insulin pens and monitors the date, time and dose of injections, the type of insulin injected, the duration of injections and insulin temperature. The Insulclock 360 app allows automatic data logging, report generation and reminder setting, among other functions. In this study, we pretend to show the clinical impact of Insulclock system, both device and mobile application, on glycemic indices, treatment compliance, and quality of life in patients with persistent poorly controlled T1DM. Material and methods: Randomized open-label multicenter controlled trial to evaluate glycemic control, the number of missed and delayed insulin doses, and quality of life after seven weeks of Insulclock 360 use in participants with uncontrolled DM1. We will also compare these results between patients with or without receiving system reminders and alerts. This study aims to assess the effect of Insulclock on glycemic control, treatment adherence, and quality of life. As a secondary objective, we will compare the study outcomes between participants in the Active and Masked Insulclock groups (i.e., with or without receiving alerts and reminders and accessing the app). To assess glycemic control, we will measure HbA1C and glycemic indices. Glycemic variability indices will be monitored with the FreeStyle Libre™ and included glucose coefficient of variation (CV), standard deviation (SD), time in range (TIR), time above range (TAR), and time below range (TBR). Mean glucose levels will be obtained from 48-h time intervals with the FreeStyle Libre. A late meal bolus (mistimed) will be considered when Insulclock detects the injection at least 30 minutes after the CGM rise. To identify meal glucose excursions, we will use the Glucose Rate Increase Detector (GRID) algorithm, which estimates the rate of change (ROC) of glucose from CGM data. Participants will complete the ITSQ and the DTSQ, which are validated questionnaires to assess the diabetes treatment satisfaction.


Clinical Trial Description

Study design: This multicentric randomized open-label study will be conducted at the Hospital General de Segovia (Segovia, Spain), Hospital de Cruces (Bilbao, Spain), Hospital Arquitecto Marcide (Ferrol, A Coruña, Spain) and Hospital Central de Asturias (Oviedo, Spain) after classification by the Spanish Agency for Medicines and Health Products (AEMPS) and ethical approval by the Ethics Review Committee of each research center. The study will be conducted in compliance with the ethical principles of the Declaration of Helsinki. Each participant will provide written informed consent before being included in the study. The study is scheduled across seven visits. At Visit 1 (Screening, Week -1), demographic and clinical information will be collected, and concomitant medications will be registered. All potential study patients will be screened for eligibility after signing the informed consent form (ICF) and will be assigned with a patient identification number. Laboratory evaluations (HbA1c, serum chemistry) must be available within the last 2 months. An identification number will be assigned to each participant At Visit 2 (Run-in, week 0), participants will receive information on the use of the Insulclock device and app on masked mode (excluding the use of Insulclock 360 app information and alarms). If the participant does not use a CGM: a healthcare professional applies the FreeStyle Libre sensor to the back of the upper arm and activates it. If the participant already uses a CGM system, the patient will be encouraged to use sensors during this period. At Visit 3 (First Visit CGM 1, week 1) and Visit 4 (Follow-up, week 3), participants will be encouraged to use the system At Visit 5 (Visit Starting CGM 2 and Randomization, week 4) participants will be randomized (1:1) to the Active Insulclock group or the Masked Insulclock group. Participants randomized in the Insulclock Active Group will receive detailed instructions on using the Insulclock device and Insulclock 360 mobile application and will be instructed and motivated for full use of all system functions (alarms, messages to the caregivers and investigation team). Participants randomized in the Insulclock Masked Group will be instructed on the correct installation and use of the Insulclock system for recording insulin bolus information but they will not receive any other information and will not have access to the Insulclock 360 application from the Internet and will keep administering insulin treatment as before. A healthcare professional will apply a FreeStyle Libre sensor to the upper arm in all the participants who do not use a CGM and will be encouraged to wear the sensor for 2 weeks. Participants who already use a CGM system will be encouraged to use sensors during this period. At Visit 6 (Final Visit CGM 2 and Randomization, week 6). Participants will receive a reminder on the use of Insulclock according to the corresponding group. At Visit 7 (Final Visit, week 7) the mobile application diaries will be collected and reviewed. Participants will receive to fill in the Insulin Treatment Satisfaction Questionnaire (ITSQ) and the Diabetes Treatment Questionnaire (DTSQ). Study population Investigators will include 80 participants aged 18-80 years with uncontrolled T1DM who provide written informed consent. Persistent uncontrolled T1DM was defined as HbA1C levels ≥6.5% for at least 1 year, and/or variations ≥1% in HbA1C within the previous 2 years and attending regular (more than 2 per year) follow-up visits at the Endocrinology department. Investigators will exclude pregnant or breastfeeding women, individuals with a history of or current alcohol or drug abuse, acute infection, cognitive decline or dementia, or any illness or condition that could interfere with the trial. Study devices: Insulclock is a small electronic device that works as an add-on module of insulin pens. This device can record the dose and time of insulin injected, register temperature changes of insulin pens, record the duration of an injection, and the specific insulin pen used. In the present study, participants self-administer insulin with pens coupled to Insulclock and according to routine clinical practice. By means of acoustic and visual alarms, participants receive information for a correct injection technique (an alert if the injection time was <6 seconds) or to prevent stacking insulin (an alert if a previous injection was done within the 2 previous hours). The Insulclock device is synchronized with the Insulclock 360 app for the automatic logging of patient data. The Insulclock 360 app also has a reminder function to promote the timely administration of insulin doses. Users can also receive customized tips on DM management with the "my tutors" tool and obtain information on DM topics. Insulclock 360 app is compatible with Apple and Android operating systems. In the Active group, participants will receive acoustic and visual alarms, device-related information and will have access to the Insulclock 360 app. In the Masked group, participants know the dose, time and duration of injections, but these participants will not receive any reminder and will be masked to the Insulclock 360 app. Participants will use the Freestyle Libre (Abbott Diabetes Care, Witney, Oxon, UK) for the continuous monitoring of glucose levels. This flash continuous monitoring system is to be worn on the upper arm and does not require capillary glucose concentrations for calibration. The sensor automatically records glucose data every 15 minutes for 14 days. Statistical Analysis The proposed statistical analysis methods constitute a synthesis of the methods to be used in this study to apply them to the data collected and respond to the general objective and the specific objectives. Data from all participants included in the study, who meet the selection criteria, will be analyzed. Data in absentia will not be charged and will be considered as lost. A general description of the variables included in the study will be made. The absolute and relative frequency distributions of the qualitative variables will be presented by investigators, as well as the measures of central tendency and dispersion (mean, standard deviation, median, minimum and maximum) of the quantitative variables. The confidence intervals will be presented at 95% for the main quantitative outcome variables associated with the main objective and the main secondary variables. The data corresponding to the variables included in the main objective will be descriptively analyzed. Investigators will use the SPSS software Version 17.0. to perform the analysis. The hypothesis tests that are carried out will be in all bilateral cases and with a significance level of 0.05. For variables that do not fit the normal distribution(or parametric), the Mann Whitney hypothesis tests will be used (for unpaired data). The chi-square test (or Fischer's exact test when appropriate) will be used for the analysis of contingency tables as well as for the comparison of proportions and/or frequency distributions. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04847778
Study type Interventional
Source Hospital General de Segovia
Contact
Status Completed
Phase N/A
Start date March 1, 2021
Completion date July 31, 2021

See also
  Status Clinical Trial Phase
Completed NCT04030091 - Pulsatile Insulin Infusion Therapy in Patients With Type 1 and Type 2 Diabetes Mellitus Phase 4
Terminated NCT03605329 - Evaluation of the Severity of Cardiovascular Autonomic Neuropathy in Type 1 Diabetic Patients With OSAS N/A
Completed NCT01696266 - An International Survey on Hypoglycaemia Among Insulin-treated Patients With Diabetes
Recruiting NCT06050642 - Study of the Impact of PROximity Support for Patients With Type 1 DIABetes Treated With an Insulin Pump or Closed Loop. N/A
Completed NCT05107544 - Metabolic, Physical Fitness and Mental Health Effects of High Intensity Interval Training (HIIT) in Adolescents With Type 1 Diabetes N/A
Active, not recruiting NCT04443153 - Adapting Diabetes Treatment Expert Systems to Patient in Type 1 Diabetes N/A
Completed NCT04569994 - A Study to Look at the Safety of NNC0363-0845 in Healthy People and People With Type 1 Diabetes Phase 1
Completed NCT04521634 - Glycaemic Variability in Acute Stroke
Completed NCT04089462 - Effects of Frequency and Duration of Exercise in People With Type 1 Diabetes A Randomized Crossover Study N/A
Completed NCT03143816 - Study Comparing Prandial Insulin Aspart vs. Technosphere Insulin in Patients With Type 1 Diabetes on Multiple Daily Injections: Investigator-Initiated A Real-life Pilot Study-STAT Study Phase 4
Completed NCT01892319 - An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
Recruiting NCT04039763 - RT-CGM in Young Adults at Risk of DKA N/A
Completed NCT04042207 - Diabeloop for Highly Unstable Type 1 Diabetes N/A
Not yet recruiting NCT06068205 - COMPARATIVE ANALYSIS OF THE MORPHO-MECHANICAL PROPERTIES OF RED BLOOD CELLS EXTRACTED FROM DIABETIC PATIENTS WITH AND WITHOUT MICROVASCULAR COMPLICATIONS
Recruiting NCT05909800 - Prolonged Remission Induced by Phenofibrate in Children Newly Diagnosed With Type 1 Diabetes. Phase 2
Active, not recruiting NCT04974528 - Afrezza® INHALE-1 Study in Pediatrics Phase 3
Completed NCT04530292 - Home Intervention and Social Precariousness in Childhood Diabetes N/A
Completed NCT05428943 - OPT101 in Type 1 Diabetes Patients Phase 1
Recruiting NCT03988764 - Monogenic Diabetes Misdiagnosed as Type 1
Completed NCT05597605 - The SHINE Study: Safety of Implant and Preliminary Performance of the SHINE SYSTEM in Diabetic Subjects N/A