Diabetes Mellitus Clinical Trial
Official title:
Reliability of the Freestyle Libre CGM in the Inpatient Setting During the COVID-19 Surge
The FDA has provided an emergency waiver for the use of non-invasive continuous glucose monitors (CGM) in hospitals, so frontline health care providers (in hospitals) can remotely monitor patients with diabetes thus reducing patient's discomfort, limiting exposure to COVID-19 and preserving critical personal protective equipment (PPE). The FreeStyle Libre 14-day system is a continuous glucose monitoring system consisting of a handheld reader (smart phone may be used) and a sensor applied with adhesive to back of the upper arm. In order to evaluate the reliability of the Freestyle Libre CGM for in-patient use, we propose a study which will examine the correlation between the libre CGM data and capillary blood glucose test - the current standard of care taken by the Accuchek Inform II platform.
In hospitalized patients diagnosed with COVID-19, diabetes mellitus is associated with a higher mortality. Patients with controlled blood glucose have a lower mortality rate than those who are uncontrolled. However, a rigid blood glucose control - which may lead to hypoglycemia- is associated with higher mortality rates. Thus, adequate glucose monitoring is important for hospitalized diabetic patients. Previous studies have shown that CGMS, in the outpatient setting, engender better glycemic control thereby reducing risk of hypoglycemia. CGMS offer a replacement for finger stick blood glucose monitoring which may not identify an incidence of hypoglycemia until symptoms drive the patient to test. Furthermore, finger stick blood glucose monitoring is painful and time consuming thus causing many patients to avoid this aspect of diabetes self-care management. Freestyle Libre CGMs sample interstitial fluid glucose subcutaneously. Measurement frequencies typically range from 1 to 15 minutes and most commonly are every 5 minutes. Previous studies in hospitalized patients living with diabetes mellitus on basal bolus regimen have shown: • Use of the CGM increased detection of both hypoglycemic and hyperglycemic events versus those sensed by POCT. One investigation identified 88 postprandial hyperglycemic excursions in patients with CGM use as opposed to 61 in those with POCT. Another noted that when comparing the CGM use with that of POCT, the former identified 55 hypoglycemic events whereas the latter only found 12. • No difference in mean daily glucose CGM and POCT readings. In a study of 38 patients, the investigators noted no difference in mean daily glucose between the CGM and POCT. ;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Completed |
NCT03743779 -
Mastering Diabetes Pilot Study
|
||
| Completed |
NCT03786978 -
Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus
|
N/A | |
| Completed |
NCT01804803 -
DIgital Assisted MONitoring for DiabeteS - I
|
N/A | |
| Completed |
NCT05039970 -
A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program
|
N/A | |
| Completed |
NCT04507867 -
Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III
|
N/A | |
| Completed |
NCT04068272 -
Safety of Bosentan in Type II Diabetic Patients
|
Phase 1 | |
| Completed |
NCT03243383 -
Readmission Prevention Pilot Trial in Diabetes Patients
|
N/A | |
| Completed |
NCT03730480 -
User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS)
|
N/A | |
| Recruiting |
NCT02690467 -
Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm.
|
N/A | |
| Completed |
NCT02229383 -
Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus
|
Phase 3 | |
| Completed |
NCT05799976 -
Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure
|
N/A | |
| Completed |
NCT06181721 -
Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes
|
N/A | |
| Recruiting |
NCT04489043 -
Exercise, Prediabetes and Diabetes After Renal Transplantation.
|
N/A | |
| Withdrawn |
NCT03319784 -
Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients
|
Phase 4 | |
| Completed |
NCT03542084 -
Endocrinology Auto-Triggered e-Consults
|
N/A | |
| Completed |
NCT02229396 -
Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo
|
Phase 3 | |
| Recruiting |
NCT05544266 -
Rare and Atypical Diabetes Network
|
||
| Completed |
NCT01892319 -
An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
|
||
| Completed |
NCT05031000 -
Blood Glucose Monitoring Systems: Discounter Versus Brand
|
N/A | |
| Recruiting |
NCT04039763 -
RT-CGM in Young Adults at Risk of DKA
|
N/A |