Diabetes Mellitus Clinical Trial
Official title:
Measurement Algorithm Control and Optimization With Subsequent Performance Evaluation of Sanmina Non-invasive Biosensors During a Standardized Meal Test in Patients With Diabetes Mellitus Type 1 and Type 2
Measurement algorithm control and optimization with subsequent performance evaluation of Sanmina biosensors in monitoring of glucose, heart rate (HR), and SpO2 in patients with type 1 and type 2 diabetes during a standardized meal experiment.
- This study is a combined, open label, prospective, comparative single-center study.
- The study is separated in 3 consecutive study parts. The first 2 study parts include 12
patients each. In the third study part 36 patients will be enrolled. Study part 1 and 2
will be used for optimization and control of the measurement algorithms of the Sanmina
biosensors. During the third study part with enrolment of 36 patients, the precision and
accuracy of the final Sanmina biosensor algorithm will be demonstrated. The study
conduct for all 60 participants of all 3 study parts will be exactly the same. In all
groups of participants, the Sanmina finger clip and wearable non-invasive monitoring
biosensor will be individually introduced and assigned. During the study visit at the
study site, a standardized meal will be given to the participants. At eleven time points
before and after the standardized meal, glucose, heart rate, and pO2 will be measured
using the Sanmina finger clip and wearable non-invasive monitoring biosensor. The
measurement time points are -30, 0, 15, 30, 45, 60, 75, 90, 120, 150 and 180 min. The
measurements will be compared to capillary blood glucose measurements by YSI Stat 2300
and StatStrip (glucose), and parallel measurements of the heart rate and the pO2 using a
patient monitor. Further the exact skin colour will be evaluated using a skin colour
card.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03743779 -
Mastering Diabetes Pilot Study
|
||
Completed |
NCT03786978 -
Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus
|
N/A | |
Completed |
NCT01804803 -
DIgital Assisted MONitoring for DiabeteS - I
|
N/A | |
Completed |
NCT05039970 -
A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program
|
N/A | |
Completed |
NCT04507867 -
Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III
|
N/A | |
Completed |
NCT04068272 -
Safety of Bosentan in Type II Diabetic Patients
|
Phase 1 | |
Completed |
NCT03243383 -
Readmission Prevention Pilot Trial in Diabetes Patients
|
N/A | |
Completed |
NCT03730480 -
User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS)
|
N/A | |
Recruiting |
NCT02690467 -
Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm.
|
N/A | |
Completed |
NCT02229383 -
Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus
|
Phase 3 | |
Completed |
NCT05799976 -
Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure
|
N/A | |
Completed |
NCT06181721 -
Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes
|
N/A | |
Recruiting |
NCT04489043 -
Exercise, Prediabetes and Diabetes After Renal Transplantation.
|
N/A | |
Withdrawn |
NCT03319784 -
Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients
|
Phase 4 | |
Completed |
NCT03542084 -
Endocrinology Auto-Triggered e-Consults
|
N/A | |
Completed |
NCT02229396 -
Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo
|
Phase 3 | |
Recruiting |
NCT05544266 -
Rare and Atypical Diabetes Network
|
||
Completed |
NCT01892319 -
An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
|
||
Completed |
NCT05031000 -
Blood Glucose Monitoring Systems: Discounter Versus Brand
|
N/A | |
Recruiting |
NCT04039763 -
RT-CGM in Young Adults at Risk of DKA
|
N/A |