Clinical Trials Logo

Clinical Trial Summary

The implantable Eversense ® CGM System obtained CE marking in 2016 for the 90-day device and in 2017 for the 180-day device.There is interest in real-world clinical evidence on the use of Eversense regarding changes in HbA1c and time in range (TIR), time below range (TBR), and time above range (TAR) in patients with type 1 diabetes. This is a prospective, multi-center, observational clinical study among adult participants aged 18 years or older with T1D and Eversense CGM System-naïve aimed to evaluate the change in HbA1c and glucometric parameters (TIR, TAR, TBR, mean daily glucose and standard deviation) in patients with T1D from multiple clinics in Italy using the Eversense CGM System for a 6-month time period.


Clinical Trial Description

A new continuous glucose monitoring system (CGM), the Eversense ® CGM System (Company Senseonics, Inc., location of Company Germantown, MD) has been developed and commercially introduced in the last 3 years. This system may overcome drawbacks and limitations of traditional transcutaneous CGM systems. It consists of a fully implantable sensor lasting up to 180 days, a removable smart transmitter providing unique on-body vibratory alerts, and a mobile medical app (MMA) displaying glucose information captured and calculated by the transmitter. The app generates pop-up messages and alerts for glucose values crossing low and high thresholds, rate of change of glucose exceeding pre-set limits, and predicted low and high glucose levels. Glucose data are uploaded and stored in the cloud. Data from the cloud can be analyzed to provide different glucometric parameters such as time in range (TIR, 70-180 mg/dL), time below range (TBR, <70mg/dL), time above range (TAR, >180 mg/dL), mean daily glucose levels, and standard deviation (SD). The safety and accuracy of the new system has been evaluated in the PRECISE, PRECISE II and the PRECISION studies. The accuracy of the system is very high and no serious adverse events and very few adverse events have been reported in pivotal trials. Among adverse events, redness/erythema, bruising and pain at the sensor insertion site occurred. The purpose of this analysis will be to evaluate the change in HbA1c and in glucometric parameters, such as TIR, TBR, TAR, mean daily glucose, and SD in patients with T1D from multiple clinics in Italy using the Eversense CGM System for a 6-month time period. This is a prospective, multi-center, observational clinical research study among adult participants aged 18 years or older with T1D across several diabetes-care centers in Italy. Patients will be required to be Eversense CGM System-naïve. Patients will be trained on the Eversense CGM System use before sensor insertion, as suggested by the current clinical practice recommendations. Specifically, they will be instructed about the principles of the sensor technology, the operational aspects of the device, and the interpretation of displayed data. No specific therapeutic recommendations will be suggested to adjust pre-meal insulin dosing. Patients will be advised to take an action when alerts will be asserted, according to general recommendations, including checking the glucose value using a traditional blood glucose meter. The following parameters will be collected for each patient: HbA1c (measured using high-performance liquid chromatography) within two months before sensor implantation and 6 months after the implantation, disease duration, prior use of CGM, and insulin therapy delivery mode (MDI or CSII). The Eversense CGM System consists of an implantable, fluorescence-based, long-term sensor; the smart transmitter worn on top of the skin above the sensor; and the medical mobile app (MMA) which operates on a mobile device (smart phone, smart watch, or iPad) and provides real-time monitoring of current and historical glucose values. The long-term sensor will be implanted by trained endocrinologists into the subcutaneous tissue of the upper arm at the end of the deltoid muscle in all patients. Patients will be registered in the Eversense Data Management System (DMS) allowing automatic uploading of sensor glucose data. Study participants will be followed according to local practice. The euglycemic target (TIR, glucose 70-180 mg/dL), TAR (glucose >180 mg/dL), TBR (glucose <70 mg/dL), mean overall daily glucose, and mean SD, will be collected from the DMS over the first 2 weeks after the first sensor implantation (baseline) and 2 weeks before the 6-month visit. HbA1c and CGM metric changes in patients using CSII and MDI treatment for insulin delivery, and in patients who were CGM-naïve and prior CGM users will be assessed to observe the differences by prior CGM use and method of insulin delivery. Specifically, patients will be categorized into four different subgroups: CSII and prior CGM use, CSII and CGM naïve, MDI and prior CGM use, and MDI and CGM naïve. Appropriate tests will be performed using SPSS (Statistical Package for Social Science) 23 for Macintosh. Variables not normally distributed will be analyzed with non parametric test or if necessary a 2-step rank transformation will be applied to normalize the variables. All patients will be informed about the finality of the research and they will be required to give informed consent in order to analyze data collected by the DMS. They will receive all scheduled visits according to clinical practice. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04160156
Study type Observational
Source University Magna Graecia
Contact
Status Completed
Phase
Start date June 5, 2018
Completion date June 30, 2019

See also
  Status Clinical Trial Phase
Completed NCT04030091 - Pulsatile Insulin Infusion Therapy in Patients With Type 1 and Type 2 Diabetes Mellitus Phase 4
Terminated NCT03605329 - Evaluation of the Severity of Cardiovascular Autonomic Neuropathy in Type 1 Diabetic Patients With OSAS N/A
Completed NCT01696266 - An International Survey on Hypoglycaemia Among Insulin-treated Patients With Diabetes
Recruiting NCT06050642 - Study of the Impact of PROximity Support for Patients With Type 1 DIABetes Treated With an Insulin Pump or Closed Loop. N/A
Completed NCT05107544 - Metabolic, Physical Fitness and Mental Health Effects of High Intensity Interval Training (HIIT) in Adolescents With Type 1 Diabetes N/A
Active, not recruiting NCT04443153 - Adapting Diabetes Treatment Expert Systems to Patient in Type 1 Diabetes N/A
Completed NCT04569994 - A Study to Look at the Safety of NNC0363-0845 in Healthy People and People With Type 1 Diabetes Phase 1
Completed NCT04521634 - Glycaemic Variability in Acute Stroke
Completed NCT04089462 - Effects of Frequency and Duration of Exercise in People With Type 1 Diabetes A Randomized Crossover Study N/A
Completed NCT03143816 - Study Comparing Prandial Insulin Aspart vs. Technosphere Insulin in Patients With Type 1 Diabetes on Multiple Daily Injections: Investigator-Initiated A Real-life Pilot Study-STAT Study Phase 4
Completed NCT01892319 - An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
Recruiting NCT04039763 - RT-CGM in Young Adults at Risk of DKA N/A
Completed NCT04042207 - Diabeloop for Highly Unstable Type 1 Diabetes N/A
Not yet recruiting NCT06068205 - COMPARATIVE ANALYSIS OF THE MORPHO-MECHANICAL PROPERTIES OF RED BLOOD CELLS EXTRACTED FROM DIABETIC PATIENTS WITH AND WITHOUT MICROVASCULAR COMPLICATIONS
Recruiting NCT05909800 - Prolonged Remission Induced by Phenofibrate in Children Newly Diagnosed With Type 1 Diabetes. Phase 2
Active, not recruiting NCT04974528 - Afrezza® INHALE-1 Study in Pediatrics Phase 3
Completed NCT04530292 - Home Intervention and Social Precariousness in Childhood Diabetes N/A
Completed NCT05428943 - OPT101 in Type 1 Diabetes Patients Phase 1
Recruiting NCT03988764 - Monogenic Diabetes Misdiagnosed as Type 1
Completed NCT05597605 - The SHINE Study: Safety of Implant and Preliminary Performance of the SHINE SYSTEM in Diabetic Subjects N/A