Clinical Trials Logo

Clinical Trial Summary

A closed loop system for diabetes care utilizing an insulin pump, continuous glucose sensing and appropriate mathematical modelling to guide insulin dosing is a goal for those with Type 1 diabetes. Yet the cost of the associated hardware will be prohibitive for many people with diabetes or their health care payers. Carbohydrate counting, insulin dose correction systems, basal bolus regimens with or without an insulin pump all facilitate glucose control but frequent adjustment to a diabetes regimen is a necessary cornerstone to successful diabetes management; if all that is used is the regimen suggested by the health care provider at a visit and this regimen is left unchanged until the next visit or contact then success will be limited. A readily available user friendly program suitable for a smart phone or tablet would have widespread applicability and benefit. The investigators hypothesize that such an app linked into a web site that facilitated review of glucose records will be acceptable to people with diabetes and improve glucose control. Our long term goal is to create an app that can advise on diabetes management.


Clinical Trial Description

Patients with Type 1 diabetes who use a smart phone will keep detailed records of their blood glucose readings, carbohydrate intake, activity and insulin doses and share them with us. The investigators have developed a smart phone app to facilitate the recording of glucose readings, Edmonton Automated Sugar Intelligence (EASI). This EASI app may be used on Android or iPhone platforms. It will link to a web site (Intelligent Diabetes Management-IDM) that houses the person's algorithm for their insulin adjustments ie their insulin regimen scale or correction factor equation, their carbohydrate ratio formula for each meal and snack, their appropriate adjustment for exercise so that entry of the timed glucose, the carbohydrate portion to be consumed and any expected activity will allow derivation of the appropriate insulin dose. This information will be entered into the EASI program associated web site by the clinical staff at the time off the visit to the diabetes program or recruitment to the study. Then, the patient simply enters the current glucose and carbohydrate intake into EASI to allow the app use their prescribed algorithm and arrive at a suggested insulin dose. It is simply using the smart phone to do what is done by mental arithmetic or on paper at present. Thus EASI-IDM is a simple clinical decision support system to assist health management. The advantage is the information is stored in real time to the IDM web site for both the person or their caregiver to review. Since weight, age, gender, renal function, phase of menstrual cycle and ambient glucose may have an impact on glycemic control the investigators will also record these details. The first substudy planned is an - Acceptability sub study survey. The team has developed the EASI app that links in with the IDM web site. The investigators want to study how well it is accepted by patients with Type 1 diabetes, whether they use it on an ongoing basis, whether it leads to them adjusting their insulin regimen themselves more frequently and finally does it improve their A1c. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02214719
Study type Interventional
Source University of Alberta
Contact
Status Completed
Phase N/A
Start date August 2014
Completion date December 31, 2016

See also
  Status Clinical Trial Phase
Completed NCT02601729 - Reimbursement Study of Continuous Glucose Monitoring in Belgium
Completed NCT01805414 - Breakfast Nutrition and Inpatient Glycemia N/A
Terminated NCT00700622 - Safety and Efficacy of Technosphere® Insulin Inhalation Powder and Lantus® Compared to Humalog® and Lantus® Over 16-Weeks Phase 3
Completed NCT00308737 - Safety of Inhaled Insulin With Type 1 and Type 2 Diabetes Phase 3
Completed NCT02657213 - Study of Insulin Pump in Prevention of Low Glucose Events in Adults With Type 1 Diabetes at Risk of Severe Hypoglycemia N/A
Terminated NCT01350102 - The Relationship of Hemoglobin A1c and Diabetic Wound Healing Phase 4
Withdrawn NCT03494010 - Hybrid Closed-Loop Insulin Delivery System in Type 1 Diabetes Candidates for a Living Donor Kidney Transplant