Clinical Trials Logo

Clinical Trial Summary

One of the challenges of current implantology involves the preservation or reduction of existing bone resorption, mainly in the buccal bone plate, after tooth loss, which becomes of special importance in the anterior region of the maxilla (aesthetic region). The study evaluates the macroscopic shape of neck implant influence in the results of immediate implants, in a population comprised of individuals from the clinic of the Faculty of Dental Medicine of the University of Porto in need of replacement of a single tooth. It is intended to evaluate the morphometric (direct measures and plaster models measurements), imaging, and photographic characteristics of the V3 implant in comparison with the C1 implant of Mis® by an evaluation period of 6 months when placing an immediate implant.


Clinical Trial Description

The study is a prospective randomized clinical trial performed by a single investigator, without a control group. The project was designed in 2016 and the participants were recruited between 2017 and 2021. Patients who met the inclusion criteria were recruited by the Unit of Oral Surgery and Implantology of the University of Porto from 2017 to 2021. The patients were fully informed of the characteristics of the study and were invited to participate. A complete medical history was taken for each of the patients, and they also underwent a thorough oral examination. The investigation was carried out in accordance with the criteria recommended in the CONSORT Guidelines. 1. Sample characterization The sample will consist of clinical cases of unitary tooth loss in the region of incisors, canines, and maxillary premolars of patients from the clinic of the Faculty of Dental Medicine of the University of Porto. The study follows ethical principles of the Ethics Committee of the Faculty of Dental Medicine, University of Porto, and guidelines from the Declaration of Helsinki for clinical trials with humans. Thus, after informed consent, the patients will be randomly grouped into 2 groups, through a closed letter draw: Group I- patients submitted to the protocol of immediate placement of the V3 Mis® implant; Group II- patients submitted to the protocol of immediate placement of C1 MIS® implant. 2. Surgical protocol Surgical protocol for implant placement (1st surgical phase): Starting with a local anesthetic administration, the incision and elevation of the mucoperiosteal flap are performed. Then the tooth is atraumatically extracted with odontosection and use of mucoperiosteal elevators, and the socket is cleaned with saline solution. After this is complete, the osteotomy for implant placement is performed, and the implant and the healing cap are placed. Finally, the implant is submerged and the surgical wound is sutured with non-resorbable 4/0 polyamide thread. For the provisional a Maryland crown was performed. Individuals are monitored monthly during the healing phase, and sutures are removed after 7 days. Pre- and post-operative therapy includes: - Antibiotic: amoxicillin, 1g (twice a day for 8 days), and in case of allergy, clarithromycin 500mg (twice a day for 8 days). Administration started on the day of surgery; - Anti-inflammatories (diclofenac 50mg, twice a day, for 4 to 5 days); - Chlorhexidine (0.2%) rinses (twice a day for 21 days). Surgical protocol for placement of a healing abutment (2nd surgical phase): Starting with a local anesthetic administration, the incision and elevation of the mucoperiosteal flap are performed. After, the healing screw is removed and the implant healing abutment (with 3x5,8mm) is placed. Finally, the surgical wound is sutured with non-resorbable 4/0 polyamide thread. Suture removal is performed after 7 days. After healing, impressions were made for the fabrication of a screw-retained cad-cam crown with platform switching concept. The investigators chose open flap implant placement without bone or connective graft placement, or immediate provisional, and direct measurement of hard and soft tissues to study the differences between implants. The goal is to evaluate only the effect of the type of coronal shape implant, minimizing the influence of other factors that could lead to bias errors. 3. Evaluations over time T-1 - First visit pre-operative:, Morphometric evaluation (clinical direct measurements and plaster models measurements), imaging (X-ray and CBCT) and photographic (PES/WES) analysis. T0 - Extraction tooth: Morphometric (clinical direct measurements) and imaging (X-ray) evaluation. T1 - Implant placed (1st surgical phase): Morphometric (clinical direct measurements) and imaging evaluation (X-ray) evaluation. T2 - 2 months submerged: Morphometric evaluation (clinical direct measurements). T3 - Healing abutment (2nd surgical phase - 4 months): Morphometric evaluation (clinical direct measurements). T3c - Definitive Crown: Morphometric evaluation(clinical direct measurements). T4 - 6 months osteointegration: Morphometric evaluation (clinical direct measurements and plaster models measurements), imaging (X-ray and CBCT) and photographic (PES/WES) analysis. 4 - Observed clinical variables: A- Bone defect: the edentulous space to be rehabilitated will be characterized in terms of the morphometric level of the existing defect in the vestibular cortical, according to the classification by Caplanis N., at time T0, in EDS-1 or EDS-2. B- Bacterial plaque index (O'Leary index): an analysis will be performed for existing plaque on teeth adjacent to the surgical site using a dichotomous score (0 = no visible plaque at the soft tissue margin, 1 = visible plaque at the soft tissue margin). C- Probing depth: analysis of the probing depth of the teeth adjacent to the site to be treated at 6 points: mesiobuccal, vestibular, distobuccal, mesiopalatal, palatine, distopalatal. The recordings will be carried out with a CP 15 UNC, Hu-Friedy® Chicago, IL, EUA manual probe. D- Bleeding on probing: performed at the 6 locations around adjacent teeth when analyzing the probing depth. E- Gingival phenotype: identified by clinical inspection with a periodontal probe. F- Implant insertion torque: recording of implant insertion torque during placement (T1). G- Implant stabilization quotient (ISQ): determination of the implant stability coefficient at the time of implant placement (T1) and in the 2nd surgical phase (T3) using the Osstell® device, the resonance frequency analysis is performed. 5 - Morphometric analysis Measurements to be assessed: 1. interdental distance: distance measured using the straight gauge between adjacent teeth at the bone crest. 2. bucco-palatal distance (BPD): distance measured by the thickness gauge in the midline of the edentulous space between the buccal edge of the buccal cortex to the palatal edge of the palatal cortex. 3. presence of papilla: evaluation through the pink aesthetics index (Pink Esthetic Score - PES, proposed by Fürhauser and collaborators, white aesthetics index (White Esthetic Score - WES, proposed by Belser UC). 4. buccal cortical distance: thickness of the buccal cortical through the thickness gauge, measured at the midline of the alveolus. 5. palatal cortical distance: thickness of the palatal cortical through the thickness gauge, measured at the midline of the alveolus. 6. mesial cortical distance: thickness of the palatal cortical through the thickness gauge, measured at the midline of the alveolus. 7. distal cortical distance: thickness of the palatal cortical through the thickness gauge, measured at the midline of the alveolus. 8. jumping distance: distance between the inner of the buccal or palatal or mesial or distal cortex and the buccal surface of the implant measured using the periodontal probe; 9. implant - cemento-enamel junction (CEJ) of adject teeth distance: determination of the vertical dimension from the occlusal surface of the implant to the cemento-enamel junction of adjacent teeth with a periodontal probe, in mesial and distal sides. 10. buccal cortical wall-implant distance: using the periodontal probe, horizontal dimension between the buccal surface of the cortical and the buccal surface of the implant, at buccal, palatal, mesial and distal cortical. 11. jumping distance space depth: maximum depth of the space between the buccal cortex and the implant wall through the periodontal probe at buccal, palatal, mesial and distal cortical. 12. distance from the implant position depth to the buccal bone crest: vertical dimension of the occlusal surface of the implant in relation to the bone crest through the periodontal probe, at buccal, palatal, mesial and distal cortical. 13. distance from the buccal cortex to the center of the implant: horizontal dimension from the buccal edge of the buccal cortex to the center of the implant with a periodontal probe, at buccal, palatal, mesial and distal cortical. 14. implant diameter: diameter of the implant. 15. Implant length: length of the implant. 16. soft tissue thickness: Soft tissue thickness was assessed using the thickness gauge at the buccal and palatal mucosa. 17. global bone volume: using the periodontal probe and thickness gauge, horizontal dimension between the buccal surface of the buccal cortical and the lingual surface of the palatal cortical, at the bone crest and 3 mm below this. 18. global volume: Soft and hard tissue thickness was assessed using the periodontal probe and thickness gauge, at the crest and 3 mm below this. 19. alveolus buccal-palatal distance: with periodontal probe. 20. alveolus mesa-distal distance: with periodontal probe. 21. alveolus depth: with periodontal probe. The morphometric analysis will be performed in all patients as follows: 5.1- Clinical direct measurements in mouth: Direct measurements will be carried out using a thickness gauge and periodontal probe ( CP 15 UNC, Hu-Friedy® Chicago, IL, EUA manual probe), with a 0.5mm. The appropriate measures will be applied, according to the chronograms times. 5.2- Plaster models measurements: Initial impressions will be made at time T-1 to prepare a thermoformed gutter with calibration traces for measurements at different surgical times. Preparation of plaster models at times T-1 and T4 and different measurements will be evaluated. 6 - Imaging analysis 6.1- Periapical X-ray: Use of the parallelism technique and use of thermoformed gutter with horizontal and vertical plane marking. Periapical x-rays will be performed at times T-1, T1,T4. 6.2- Cone Beam Computerized Tomography (CBCT): In the analysis of maxillary computed tomography, at times T-1 and T4, with radiographic guide. 7- Photographic analysis: Photographs will be taken using a Canon 450D device, a Canon Macro Lens EF 100mm lens and a Macro Ring Lite MR-14EX circular flash, with an image ratio of 1:1. 7.1- Extra-oral photographs: Initial (T-1) and final (T4) extraoral photographs will be taken at a distance of 2.5 m for replication and with reference to the occlusal plane. The reference will be the midsagittal plane and the Frankfurt plane, and the frontal photograph will be taken in the resting and smiling position, along with a profile photograph of the patient at rest and smiling. 7.2- Intra-oral photographs: Intraoral photographs will be taken during the treatment phases T-1 and T4 measuring a distance of 40 cm for replication and with reference to the occlusal plane. For this, lip retractors, intraoral mirrors, and black backgrounds will be used. Frontal photography in maximum occlusion, left and right lateral photography with only two adjacent teeth, and upper and lower occlusal photography will be performed. Evaluated measurements: The presence of papilla; The PES and WES index was evaluated through the analysis of photographs. 8- Statistical analysis The sample size was calculated from G*Power 3.1.9.6 considering F tests - ANOVA with Repeated measures, moderate effect size (f=0.30), α= 0.05, Power (1-β err prob)=0.95 and 2 groups of implants evaluated in 7 times. A descriptive analysis will be presented to characterize the qualitative and quantitative variables (gender, race, and age) presented in the form of graphs and summary tables. The statistical techniques to be adopted will be in accordance with the nature of the variables under study. Therefore, for the evaluation of quantitative measures in time, the analysis will be proposed through the ANOVA test with repeated measures with one factor (type of implant), after verifying the conditions of normality and sphericity of the variables. Measurement error control (collection of three measurements in each observation) and examiner calibration (intra-operator variability). For processing the results, the IBM Statistics software version 24.0 will be used. The decision rule will be for a statistical significance level of 5%. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05665231
Study type Interventional
Source Universidade do Porto
Contact
Status Completed
Phase N/A
Start date June 1, 2017
Completion date December 30, 2021

See also
  Status Clinical Trial Phase
Active, not recruiting NCT03908177 - Comparison of Clinical Performance and Safety of Zirconia vs. Titanium Implants: a Multi-national RCT. N/A
Completed NCT03252106 - Long-term Effectiveness of Contour Augmentation in Sites With Early Implant Placement N/A
Recruiting NCT05748379 - Atraumatic Zirconia Abutment Versus Customized Composite Healing Abutment in Maxilla or Mandible. N/A
Active, not recruiting NCT05402202 - Clinical Performance and Accuracy of Healing Abutment With Scan Peg for Single Posterior Implant-supported Restorations N/A
Completed NCT05843526 - Influence of Implant Component Materials on Peri-implant Soft Tissue Horst Response. N/A
Withdrawn NCT03575858 - The Effect of Different Shapes of Interdental Brushes in the Management of Peri-implant Mucositis and Gingivitis N/A