Clinical Trials Logo

Clinical Trial Summary

The goal if this study is to employ the CardioQ-Esophageal Aortic Doppler probe to define fluid responders from non-responders among infants undergoing cranial vault reconstruction for craniosynostosis. After defining these two groups in this single arm prospective trial, the investigators will compare the predictive utility of non-invasive devices such as the CipherOx-Compensatory Reserve Index (CipherOx-CRI) and Inferior Vena Cava Collapsibility Index (IVC CI) to currently employed indices (heart rate, systolic blood pressure, urine output and pulse pressure variability) to gauge the need for additional fluid and ongoing resuscitation. If the CipherOx-CRI or IVC CI proved to be as predictive or better at predicting fluid responders, the investigators hope to replace invasive arterial lines with non-invasive tools to guide resuscitation.


Clinical Trial Description

Predicting fluid responsiveness in the operating room is essential to guide balanced resuscitation. Aggressive resuscitation may lead to significant morbidities, such as intra-abdominal hypertension, pulmonary edema, difficulty with ventilator liberalization, and consequently increased mortality. Alternatively, under resuscitation may lead to mal-perfusion and end-organ dysfunction. A plethora of indices and tools have been studied and marketed to assess intravascular volume status with only a few proven reliable with reproducible results. Based on pre-fluid challenge values, several of these tools have been used to predict who may benefit from additional fluid (fluid responders). Alternatively, some of these tools have been used to distinguish fluid responders from non-responders based on changes in pre- and post-fluid challenge values. Among these tools, the pulmonary artery catheter provides measurements of both left and right heart pressures which can be applied to calculate the cardiac output (CO) and stroke volume (SV). Changes in these values (e.g. an increase in the stroke volume by 10%) between pre- and post-fluid challenge have been used to define fluid responders. This devise, however, is invasive with several significant risks, and therefore is rarely used in children. Echocardiography, on the other hand, is a non-invasive bedside study also used to assess CO and SV but is expensive and requires trained echosonagraphers for application. Further, because a transthoracic probe is required to obtain the images, application in the operating room is difficult as the chest is often in the operating field limiting access to the echosonagrapher. Lastly, the esophageal aortic blood flow device (CardioQ-Esophageal Dopler Monitor (Cardio-EDM), Deltex Medical, Chichester, UK) has been found in multiple adult and pediatric studies to reliably distinguish fluid responders from non-responders intensive care unit (ICU) and operating room. Much like an orogastric tube, this device is simply placed by a provider in the patient's esophagus and uses Doppler waveforms to measure aortic blood flow velocities. Variations in the amplitude of peak velocities has been shown to corelate with intravascular volume status. Specifically, a change in the peak velocity by greater than 10% between pre- and post-fluid challenge values has been shown to accurately distinguishes those who are fluid responsive from those who are not with similar accuracy to echocardiography and pulmonary artery catheter readings. In recent years with continued technological advancements, there has been enthusiasm about less invasive, and in some cases, non-invasive, tools to gauge volume status. Among these, bedside ultrasonography (performed by providers rather than sonographers) is a common tool used to evaluate the inferior vena cava (IVC) collapsibility index (CI) has been shown to be a reliable tool in adults. Another non-invasive device uses a photoplethysmoraphic probe (CipherOx-CRI) placed on a digit to calculate the compensatory reserve index (CRI), a marker of proximity to hemodynamic collapse. Both IVC CI and CRI have been shown in multiple adult studies to predictive the need for volume expansion, but their utility in the pediatric population is unknown. The goal if this proposed study is to employ the CardioQ-EDM probe to define fluid responders from non-responders among infants undergoing cranial vault reconstruction for craniosynostosis. After defining these two groups in this single arm prospective trial, the investigators will compare the predictive utility of non-invasive devices such as the CipherOx-CRI and IVC CI to currently employed indices (heart rate, systolic blood pressure, urine output and pulse pressure variability) to gauge the need for additional fluid and ongoing resuscitation. If the CipherOx-CRI or IVC CI proved to be as predictive or better at predicting fluid responders, the investigators hope to replace invasive arterial lines with non-invasive tools to guide resuscitation. The investigators chose this population for several reasons. First, the investigators institution performs approximately 50-70 of these cases a year making them a relatively accessible group. Second, these children are generally healthy which will minimize physiologic confounders. Additionally, the subjects are paralyzed, have normal respiratory compliance, and providers maintain normothermia, all of which will minimizing confounders. Another unique benefit to this population is that these infants have been nil per os for several hours prior to surgery, putting them at risk for hypovolemia, and after induction, independent of the provider's assessment of intravascular volume status, all children receive a bolus of crystalloid (10mL/kg). This baseline data should provide sufficient data for analysis; but because these procedures are associated with significant blood loss and hypovolemia requiring aggressive resuscitation in the form of fluid or blood boluses, the investigators plan to continue to collect pre- and post- bolus data with the hope to further validate the benefit of non-invasive tools such as the CipherOx-CRI and IVC CI in the setting of ongoing blood loss. As intravascular volume status is often difficult to assess clinically, the investigators aim to determine the predictability of non-invasive devices to guide resuscitation. In this prospective observational study, the investigators hope to identify: 1. The proportion of children within the cohort who are fluid responsive based on CardioQ-EDM aortic blood flow velocity changes pre- and post-bolus, 2. The positive predictive value, negative predictive value, sensitivity, specificity, and optimal threshold for CRI, IVC CI, pulse pressure variability, stroke volume variability, heart rate, systolic blood pressure, and mean arterial pressures in predicting fluid responders as determined by CardioQ-EDM, and 3. Assess confounding variables that may influence the predictive utility of such devices ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03915587
Study type Interventional
Source University of Colorado, Denver
Contact
Status Completed
Phase N/A
Start date April 8, 2019
Completion date March 12, 2020

See also
  Status Clinical Trial Phase
Suspended NCT02315937 - Hemodynamic Assessment During Spinal Anesthesia Using Transthoracic Echocardiography' N/A
Active, not recruiting NCT01681238 - Goal-directed Therapy in High-risk Surgery N/A
Completed NCT01210417 - Trauma Heart to Arm Time N/A
Recruiting NCT05557461 - Assessment of Fluid Responsiveness in Septic Shock Patients, Can End-tidal co2 Measurement Help?
Withdrawn NCT03246425 - Influence of Mechanical Ventilation Mode on Arterial Pressure Variations- a Pilot Study N/A
Completed NCT02721654 - Plasma-Lyte 148® versUs Saline Study Phase 4
Not yet recruiting NCT06072430 - VBI-S for the Treatment of Hypotension in Hypovolemic Septic Shock Patients (VBI-S-02) Phase 2/Phase 3
Completed NCT02903316 - Predicting Fluid Responsiveness in on Pump Coronary Artery Bypass Graft Using Extra Systoles N/A
Completed NCT03009305 - Cerebral Oximetry in Lower Body Negative Pressure N/A
Completed NCT01456559 - Detection of Hypovolemia Using Pleth Variability Index (PVI) N/A
Completed NCT00380107 - Volume Deficit Prior to Surgery Phase 4
Recruiting NCT06123039 - Use of Heart-lung Interaction to Predict Haemodynamic Tolerance to the Open Lung Approach With Individualised PEEP
Completed NCT04573842 - Ultrasound Assessment of the Subclavian Vein for Predicting Hypotension in Children After Anaesthesia Induction
Completed NCT05150418 - Supplemental Oxygen in Hypovolemia Phase 1
Completed NCT02961439 - Validation of Epworth Richmond's Echocardiography Education Focused Year N/A
Completed NCT01535703 - Comparison of Cardiac Output Measurement Between Transpulmonary Thermodilution and Photoplethysmography N/A
Completed NCT01010022 - Trial of 6% HES130/0.4 Phase 3
Completed NCT04641949 - Methoxyflurane and Fentanyl in LBNP Phase 4
Recruiting NCT03592290 - Hemodynamics Monitoring During Lower Body Negative Pressure (LBNP) Induced Controlled Hypovolemia
Suspended NCT03736421 - Observational Study to Evaluate Peripheral IntraVenous Analysis (PIVA) in Euvolemic, Hypovolemic, and Hypervolemic Emergency Department Patients