NCT ID: NCT04623073 Active, not recruiting - Coxarthrosis Clinical Trials

The External Obturator Footprint as a Landmark for Stem Depth in Direct Anterior Total Hip Arthroplasty - Clinical Validation

Start date: January 1, 2021
Phase:
Study type: Observational

One of the goals of Total Hip Arthroplasty (THA) is to reconstruct leg length as adequately as possible. In order to achieve this one needs landmarks that are visible both on the templating X ray as well as during surgery. The classical posterior and lateral approaches often rely on the distance from the greater trochanter (GT) to the shoulder of the femoral stem or the distance from the lesser trochanter (LT) to the side of the neck osteotomy. If the surgeon finds out on the digital template that the distance from the GT to the shoulder of the implant should be X mm to achieve equal leg length, than the surgeon can try to reconstruct this during surgery. During the Direct Anterior Approach (DAA) these landmarks usually are not visible or require additional dissection injuring important soft tissue structures along the way. One anatomical structure that appears to be always visible during the DAA is the External Obturator tendon (EO). It was recently confirmed that the level of insertion of the EO onto the proximal femur can also always be determined on pre-operative X rays. It therefore represents one of the few landmarks that is visible both on the templating X ray as well as during DAA THA. Indeed, many hip surgeons, including ourselves, believe that if the shoulder of the femoral stem is near the insertion of the EO leg length cannot be far off. However, there is no clinical data to support this. The investigators would therefore like to the correlate the distance observed intra-operatively to the actual established distance on the post-operative X ray.

NCT ID: NCT01578746 Active, not recruiting - Coxarthrosis Clinical Trials

Comparison Between Anterior and Direct Lateral Approach in Total Hip Arthroplasty

Start date: January 2012
Phase: Phase 4
Study type: Interventional

In total hip arthroplasty several approaches can be used. The newly introduced minimally invasive anterior approach is supposed to cause less damage to tendons and muscles. At the same time there are reports that there are more complications when this approach is used. The direct lateral approach is the most used in Norway and is well documented. There are however those who postulate that there is to high risk of damage to the gluteus medius causing Trendelenburg gait. In the investigators hospital both the anterior and direct lateral approach is used with good result. The investigators main study hypothesis is that there is no difference between the use of anterior or direct lateral approach i total hip arthroplasty in regards to postoperative function and pain, complications, radiological finds (X-ray and MRI), markers for muscle damage (i.e CK-total) or other clinical outcomes.

NCT ID: NCT01326832 Active, not recruiting - Coxarthrosis Clinical Trials

10 Year Clinical Evaluation of Primoris Hip Component

Primoris
Start date: September 2011
Phase:
Study type: Observational

Using the traditional and hitherto used uncemented hip prostheses achieved good clinical results, but one of the drawbacks is the risk of fracture in the femoral shaft in indbankning of the prosthesis (1-2%). In addition, the bone scan demonstrated that in the years after surgery dropped almost 30% of bone mass in the femoral shaft. This bone loss increases the risk that in the years after surgery, the increased risk of fractures around the prosthesis and in addition to impeding the described bone replacement prosthesis later. The newly developed prosthesis is anchored in the femoral neck and thus not involve the femoral shaft. This ensures a more physiological or normal weight transfer to the femur bone. This contributes to bone mass in long large extent preserved in the years after surgery, so you have a better opportunity later to make a new prosthesis surgery with good results. The new prosthesis should be capable of simultaneously reducing the incidence of thigh pain in the first year after surgery.'

NCT ID: NCT00722982 Active, not recruiting - Coxarthrosis Clinical Trials

Migration Pattern of C-stem AMT Versus Exeter in Total Hip Arthroplasty

Start date: July 2008
Phase: N/A
Study type: Observational

Hypothesis: Migration of C-Stem AMT is equal to the well documented Exeter prosthesis In Norway it is annually performed approximately 600 primary and 100 revisions THA. Osteolysis around the prosthesis is one of the major difficulties while performing revision surgery. C-stem is a triple tapered cemented prosthesis designed to increase the stress and strain of proximal femur and thereby decreasing osteolysis. We are planning til include 70 patients and randomize to C-stem AMT or Exeter prosthesis. Both prosthesis will be combined with previously non documented "Marathon" acetabular prosthesis. The result will be followed clinically and with RSA and DXA. Soft endpoint after 2 years

NCT ID: NCT00318396 Active, not recruiting - Coxarthrosis Clinical Trials

Compaction Femur Preparation for Cementless Total Hip Arthroplasty (THA) Unilateral

Start date: June 2004
Phase: N/A
Study type: Interventional

This is a prospective, randomized study comparing two different bone preparation techniques for insertion of a hydroxylapatite (HA) coated titanium cementless femoral stem. Patients who receive a unilateral total hip replacement are randomized to either conventional broaching or compaction. Hypothesis: Compaction results in significantly less stem migration [evaluated by radiostereometric analysis (RSA)], less peri-prosthetic bone mineral density (BMD) loss [evaluated by dual energy x-ray absorptiometry (DEXA)], and a higher Harris hip score after two years.