Coronary Stenosis Clinical Trial
Official title:
Clinical and Angiographic Evaluation of Paclitaxel Eluting, Non-Polymeric, Nanoporous Carbon-Carbon Coated, Cobalt-Chromium Stent
Coronary artery disease (CAD) is the largest cause of death and disability in the world. Besides medicines, the principle treatment of this condition requires opening of the narrowed arteries, responsible for angina and other symptoms of the disease, by angioplasty or surgery. Introduction of metal scaffolds called 'stents' in the past few decades revolutionised the angioplasty technique, and has made it the most popular treatment today for CAD. However these stents are prone to becomin narrow and obstructed after implanataion, causing symptoms and non-fatal heart attacks in some patients. Introduction of stents that slowly release drugs locally to minimize this process, called 'drug-eluting stents'(DES)he past few years has been one of the biggest breakthroughs in the field of cardiology. However ven the current available DES are still prone to narrowing in high-risk patients, like those with diabetes, and also have a higher chance for sudden blockage by a blood clot even many years later after insertion. Thus it is important to develop technology for more efficacious and safer DES.This includes safer drugs, better stent design and delivery, and more inert platforms for drug release We hypothesise that a new stent made with nanoporous particle with better polymer for drug release will prove to be safer and more efficacious alternative to currently available DES.
Status | Recruiting |
Enrollment | 200 |
Est. completion date | October 2007 |
Est. primary completion date | |
Accepts healthy volunteers | No |
Gender | Both |
Age group | 18 Years to 70 Years |
Eligibility |
Inclusion Criteria: 1. Male or non-pregnant female 2: 18 years of age (note: females of child bearing potential must have a negative pregnancy test within 7 days of treatment and must use effective pregnancy avoidance until the 6 month angiogram is completed) 2. Have chest pain consistent with angina pectoris or a history of documented myocardial infarction or documented silent ischemia 3. Treatment of a native vessel de novo coronary lesion (only 1 single study lesion/patient) 4. Target vesseI2.5mm-4.0mm in diameter (visual estimate) 5. Target lesion length::: 12mm (visual estimate) 6. Target lesion stenosis> 50% and < 100% (visual estimate) 7. At least TIMI grade II coronary flow 8. Acceptable candidate for CABG surgery 9. Patient is willing to come back for a follow-up evaluations including repeat cardiac catheterization 5-7 months after treatment 10. Patient must provide written informed consent prior to the index procedure using a form that is approved by the local Ethics Committee Exclusion Criteria: 1. Patient has experienced an acute myocardial infarction (Q wave or non-Q wave) within 72 hours prior to the index procedure with CK enzymes 2: 2x the local laboratory upper limit of normal, with the presence of CK- MB levels elevated above the local laboratory upper limit of normal; 2. Unprotected left main coronary disease with> 50% stenosis; 3. Significant (> 50%) stenosis proximal or distal to the target lesion that might require revascularization or impede runoff; 4. Ostial location of the target lesion; 5. Angiographic evidence of thrombus within the target lesion; 6. Severely calcified'lesion which cannot be successfully predilated; 7. Documented L VEF < 25%, or clinically significant congestive cardiac failure; 8. Totally occluded vessel; 9. Impaired renal function (creatinine> 0.27mmol/L) at the time of treatment; 10. Pretreatment with devices other than balloon angioplasty; 11. Excessive tortuosity proximal to the lesion which makes stent delivery and deployment uncertain; 12. Target lesion involves a bifurcation including a diseased side branch> 2.5mm in diameter that would require treatment; 13. Prior stenting within 5mm of the target lesion; 14. Patient is a recipient of a heart transplant; 15. Patient has a life expectancy < 12 months; 16. Known allergies to clopidogrel bisulfate (Plavix@), ticlopidine (Ticlid@), Cobalt Chromium alloy and Paclitaxol that cannot be medically managed; 17. In the investigator's opinion, any significant medical condition which may interfere with the patient's optimal participation in this study; 18. Currently participating in an investigational drug or device study that has not completed the primary endpoint; 19. Intervention of another coronary lesion has occurred within 30 days before or is planned within 30 days after the index procedure. 20. In the investigator's opinion, the lesion is not suitable for stenting |
Allocation: Non-Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment
Country | Name | City | State |
---|---|---|---|
India | All India Institute of Medical Sciences | New Delhi | Delhi |
Lead Sponsor | Collaborator |
---|---|
All India Institute of Medical Sciences, New Delhi |
India,
Bhargava B, Reddy NK, Karthikeyan G, Raju R, Mishra S, Singh S, Waksman R, Virmani R, Somaraju B. A novel paclitaxel-eluting porous carbon-carbon nanoparticle coated, nonpolymeric cobalt-chromium stent: evaluation in a porcine model. Catheter Cardiovasc Interv. 2006 May;67(5):698-702. — View Citation
Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, Colombo A, Schuler G, Barragan P, Guagliumi G, Molnàr F, Falotico R; RAVEL Study Group. Randomized Study with the Sirolimus-Coated Bx Velocity Balloon-Expandable Stent in the Treatment of Patients with de Novo Native Coronary Artery Lesions. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002 Jun 6;346(23):1773-80. — View Citation
Stone GW, Ellis SG, Cox DA, Hermiller J, O'Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME; TAXUS-IV Investigators. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med. 2004 Jan 15;350(3):221-31. — View Citation
van der Giessen WJ, Lincoff AM, Schwartz RS, van Beusekom HM, Serruys PW, Holmes DR Jr, Ellis SG, Topol EJ. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation. 1996 Oct 1;94(7):1690-7. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | In-stent late loss as compared historically to other DES, within the stented segment post-procedure and at 6-9-month follow-up | |||
Secondary | Major adverse cardiac events | |||
Secondary | Stent thrombosis rate (acute, subacute, or chornic) |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
Recruiting |
NCT03427996 -
Evaluation of Effectiveness and Safety of Rotational Atherectomy in Routine Clinical Practice
|
||
Terminated |
NCT03175523 -
HOW To Optimally Implant BioResorbable Scaffold - Intravascular Imaging Versus Quantitative Coronary Angiography Guidance
|
N/A | |
Active, not recruiting |
NCT04475380 -
Complex All-comers and Patients With Diabetes or Prediabetes, Treated With Xience Sierra Everolimus-eluting Stents
|
||
Completed |
NCT01184183 -
Trial Comparison of Accuseal and Bovine Pericardial Patch During Endarterectomy
|
||
Completed |
NCT00697372 -
SEA-SIDE: Sirolimus Versus Everolimus-eluting Stent Randomized Assessment in Bifurcated Lesions and Clinical SIgnificance of Residual siDE-branch Stenosis
|
Phase 4 | |
Completed |
NCT05509296 -
Compare the Effectiveness and Safety of Two Different Kinds of Cutting Balloon in Coronary Artery Disease
|
N/A | |
Recruiting |
NCT03054324 -
Validation of a Predictive Model of Coronary Fractional Flow Reserve in Patients With Intermediate Coronary Stenosis
|
||
Enrolling by invitation |
NCT06194526 -
Whole Blood Transcriptomic Signal According to Coronary Atherosclerotic Plaque Burden Assessed by CT Angiography
|
||
Not yet recruiting |
NCT06039748 -
Angiography-Derived Quantitative Functional Assessment Versus Pressure-Derived FFR and IMR: The FAIR Study
|
||
Not yet recruiting |
NCT05753085 -
Multimodality Optical and Ultrasound Intravascular Imaging for Stent Optimization and Atheroma Assessment
|
N/A | |
Not yet recruiting |
NCT05471687 -
Evaluation of the Functional Impact of Coronary Stenoses in Diabetics by Spectral CT
|
N/A | |
Not yet recruiting |
NCT04569669 -
The Sensitivity and Specificity of CardioSimFFRct Analysis Software on Coronary Artery Stenosis
|
N/A | |
Active, not recruiting |
NCT02508714 -
Bioresorbable Polymer ORSIRO Versus Durable Polymer RESOLUTE ONYX Stents
|
N/A | |
Completed |
NCT03301246 -
Artimes Pro Low Profile Dilatation Catheters for Pre-Dilatation in Patients With Symptomatic Ischemic Heart Disease
|
N/A | |
Completed |
NCT03606330 -
Systemic, Pancoronary and Local Coronary Vulnerability
|
||
Completed |
NCT02870140 -
Thin Strut Sirolimus-eluting Stent in All Comers Population vs Everolimus-eluting Stent
|
N/A | |
Not yet recruiting |
NCT06071702 -
IonMAN II Trial- Early Feasibility Study of the IoNIR Ridaforolimus-Eluting Coronary Stent System
|
N/A | |
Completed |
NCT02275143 -
Computed Tomography (CT) Coronary Angiogram Evaluation in Cancer Patients Having CT Thorax, Abdomen and Pelvis
|
N/A | |
Active, not recruiting |
NCT01794065 -
The Promus Element Rewards Study
|
N/A |