Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT05606367
Other study ID # NAD-D-001
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date January 3, 2023
Est. completion date October 2023

Study information

Verified date April 2023
Source Shanghai MicroPort Rhythm MedTech Co., Ltd.
Contact Tingting Wu, M.D.
Phone 0086-021-38954600
Email TingTing.Wu2@microport.com
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This is a prospective, multicenter, randomized controlled clinical investigation aiming to evaluate the safety and effectiveness of non-slip balloon catheter for the treatment of patients with coronary artery stenosis.


Description:

This trial is a prospective, multicenter, randomized controlled clinical trial. 200 subjects are expected to be recruited in 7 research centers in China and randomly divided into two groups according to the ratio of test group: control group = 1:1. The primary endpoint is the acute lumen gain. All subjects receive clinical follow-up during hospitalization and 30 days after surgery.


Recruitment information / eligibility

Status Recruiting
Enrollment 200
Est. completion date October 2023
Est. primary completion date August 2023
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Clinical Inclusion Criteria: 1. Subjects aged=18 years. 2. Subjects with silent myocardial ischemia, symptomatic angina pectoris, or old myocardial infarction. 3. Subjects who can undergo percutaneous coronary intervention (PCI). 4. Subjects who are able to understand the purpose of the trial, participate voluntarily and indicate by signing the informed consent form that they recognize the risks and benefits described in the informed consent document and are willing to undergo clinical follow-up. Angiography Inclusion Criteria: 1. For subjects with single or double lesions, revascularization is required for up to two lesions; at most one non-target lesion can be treated in the same period, and the target lesion can be treated only after the treatment of non-target lesion meets the angiography success criteria and there is no complication. Target and non-target lesions must be located in different major epicardial vessels. 2. Target lesion meets criteria for revascularization: 1. = 70% and < 100% diameter stenosis; or 2. = 50% and < 70% diameter stenosis with clinical evidence of ischemia 3. Target lesion vessel diameter is between 2.0 mm and 4.0 mm (inclusive), target lesion length = 30 mm. 4. Clinically judged to be the lesion that requires or is amenable to pretreatment with the study balloon catheter and that the study balloon catheter can pass after pre-dilatation. General Exclusion Criteria: 1. Subjects who present with AMI recently (within 7 days). 2. Subjects who plan to undergo rotational atherectomy, laser coronary atherectomy, cutting balloon during target lesion pretreatment. 3. Subjects who are scheduled for PCI or CABG within 1 month of the index procedure. 4. Subjects with history of ischemic stroke or transient ischemic attack within 3 months. 5. Subjects with bleeding tendency, active gastrointestinal ulcer, history of cerebral hemorrhage or subarachnoid hemorrhage, contraindications to antiplatelet agents and anticoagulant therapy, and inability to receive antithrombotic therapy within 6 months. 6. Subjects who are scheduled for additional surgical procedures requiring discontinuation of aspirin, clopidogrel within 6 months of the baseline procedure. 7. Subjects with severe heart failure (NYHA III and above) or left ventricular ejection fraction(LVEF) < 35% (ultrasound or left ventriculography) and/or hemodynamic instability. 8. Subjects with unstable arrhythmias, such as high-risk premature ventricular contractions, ventricular tachycardia, high-grade atrioventricular block. 9. Subjects who are unable to receive antiplatelet therapy. 10. Subjects with hypersensitivity to aspirin, heparin, contrast agent, cobalt-based alloys (including metal elements such as cobalt, chromium, nickel, and tungsten), and polytetrafluoroethylene. 11. Subjects with renal insufficiency, serum creatinine greater than 177 µmol/L (2.0 mg/dl) or who are receiving hemodialysis. 12. Subjects who have been diagnosed with the terminal state of acute and chronic diseases such as advanced cancer and have a life expectancy of less than 1 year. 13. Subjects who have already received or are waiting for organ transplantation. 14. Subjects with blood routine test showed platelet count less than 50 × 10^9/L or more than 700 × 10^9/L, and/or hemoglobin less than 70 g/L. 15. Subjects who have participated in other clinical trials of drugs or medical devices before enrollment but have not been to the primary study endpoint until now. 16. Subjects who are judged by the investigator to be at high clinical risk for the use of the study device, unsuitable or non-compliant, and unable to complete the study as required. 17. Subjects who are pregnant or breastfeeding (women who may become pregnant must have a pregnancy test within 7 days prior to the baseline procedure). Angiography Inclusion Criteria: 1. There are three severe lesions that needs revascularization. 2. Unprotected left main disease. 3. Target lesions meeting the following criteria: - Acute occlusion or thrombus; - Chronic total occlusion; - Bifurcation lesion; - Within 3 mm of the ostium of the left and right main coronary arteries (LAD/LCX/RCA); - CABG bridge stenosis; - Involved myocardial bridge; - Presence of dissection (Type C and above according to NHLBI classification); - Anatomy proximal to or within the target lesion that would preclude delivery of the study balloon catheter (e.g., severe tortuosity, etc.); - The study balloon catheter must pass previously implanted stent to reach target lesion.

Study Design


Intervention

Device:
Non-slip Balloon Catheter of Shanghai MicroPort Rhythm
The principle of Non-slip Balloon Catheter in dilating stenotic lesions is mechanical extrusion of the vessel through the balloon, resulting in irregular rupture of atheromatous plaque and enlargement of the lumen.
NSE Coronary Dilatation Catheter
The Lacrosse® NSE is an angioplasty catheter with 3 longitudinal elements attached directly proximal and distal to the balloon that produces 3 endovascular surgical incisions during balloon dilation.

Locations

Country Name City State
China Renji Hospital Shanghai Jiaotong University School of Medicine Shanghai Shanghai

Sponsors (1)

Lead Sponsor Collaborator
Shanghai MicroPort Rhythm MedTech Co., Ltd.

Country where clinical trial is conducted

China, 

Outcome

Type Measure Description Time frame Safety issue
Primary Acute Lumen Gain Acute lumen gain is defined as the difference in the minimum lumen diameter of the target lesion before and after dilatation with the study balloon catheter (Microport or NSE Coronary Dilatation Catheter) as measured by QCA. (Acute lumen gain = minimum lumen diameter measured after dilatation with the study balloon catheter - minimum lumen diameter measured before dilatation with the study balloon catheter, AG=MLD post - MLD pre) Baseline procedure
Secondary Device success Device success is defined as successful delivery, inflation, deflation, and withdrawal of the study balloon catheter with < 50% diameter stenosis of the lesion after dilatation. Baseline procedure
Secondary Lesion success Lesion success is defined as a target lesion with = 30% residual stenosis and TIMI flow grade of 3 after treatment with any interventional method. Baseline procedure
Secondary Procedural success Procedure success is defined as having a target lesion with = 30% diameter residual stenosis and TIMI flow grade of 3 after PCI procedure while the device was successful. There were no deaths, target vessel revascularization, or myocardial infarction during hospitalization (up to 7 days after baseline procedure). During hospitalization (up to 7 days after procedure)
See also
  Status Clinical Trial Phase
Recruiting NCT05133843 - Complete Functional Assessment of Intermediate Coronary Artery Stenosis Before and After Transcatheter Aortic Valve Implantation (TAVI) in Patients With Severe Symptomatic Aortic Valve Stenosis N/A
Completed NCT01205776 - EXCEL Clinical Trial N/A
Completed NCT00739466 - Biorest Liposomal Alendronate With Stenting sTudy (BLAST) Phase 2
Completed NCT01182428 - XIENCE V: SPIRIT WOMEN Sub-study Phase 4
Completed NCT01332591 - Multivessel Disease Diagnosed at the Time of PPCI for STEMI: Complete Revascularization Versus Conservative Strategy. N/A
Completed NCT00531011 - EXecutive RCT: Evaluating XIENCE V® in a Multi Vessel Disease Phase 4
Completed NCT01310309 - EXecutive Registry: Evaluating XIENCE V® in a Multi Vessel Disease Phase 4
Not yet recruiting NCT06052670 - Functional Diagnostic Accuracy of Ultrasonic Flow Ratio in Assessment of Coronary Artery Lesions
Completed NCT05509296 - Compare the Effectiveness and Safety of Two Different Kinds of Cutting Balloon in Coronary Artery Disease N/A
Not yet recruiting NCT05393882 - Impact of Cholesterol Level on Long-term Coronary Bypass Graft Patency
Recruiting NCT06397820 - Relation Between AI-QCA and Cardiac PET
Active, not recruiting NCT01960504 - First in Man Study of the DREAMS 2nd Generation Drug Eluting Absorbable Metal Scaffold (BIOSOLVE-II) N/A
Completed NCT01721096 - XIENCE PRIME Japan Post-Marketing Surveillance (PMS)
Active, not recruiting NCT01342822 - Trial to Assess the Everolimus-Eluting Coronary Stent System (PROMUS Element) for Coronary Revascularization Phase 4
Completed NCT01205789 - EXCEL Clinical Trial (Universal Registry) N/A
Recruiting NCT05532605 - Effects of Mindfulness Based Therapy on Illness and Depression in Cardiac Rehab Phase-i N/A
Completed NCT02066623 - Observational Study to Evaluate Short and Long-term Safety of the ABSORB Scaffold
Not yet recruiting NCT02946320 - Optimal Predilatation Technique for BVS Implantation Phase 3
Completed NCT01249027 - XIENCE V Everolimus Eluting Coronary Stent System (EECSS) China: Post-Approval, Single-Arm Study
Terminated NCT01136915 - Kidney Damage In Patients With Severe Fall In eGFR Phase 4