Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT04857762
Other study ID # 1292/2021
Secondary ID
Status Not yet recruiting
Phase
First received
Last updated
Start date May 1, 2021
Est. completion date March 1, 2024

Study information

Verified date April 2021
Source Szabolcs - Szatmár - Bereg County Hospitals and University Teaching Hospital, András Jósa Teaching H
Contact Zsolt Koszegi, MD, PhD
Phone +36-30-2589442
Email dr.koszegi.zsolt@szszbmk.hu
Is FDA regulated No
Health authority
Study type Observational [Patient Registry]

Clinical Trial Summary

The READY register is a multicenter open label registry of patients underwent invasive intracoronary FFR and RFR measurement using the Quantien system. The register collects clinical and epidemiological data of patients scheduled for invasive coronary physiology.


Description:

Angiographic evaluation protocol: Coronary diagnostic angiography is performed according to the routine clinical practice. The visual estimate of the diameters stenosis % of the culprit lesion(s) should be input prospectively in the modified Syntax segmentation scheme (https://coronart.hu/) where the corresponding ventricular segments supply is indicated on a polar map. On the same time, the operator is required to record characterize the coronary vessel disease as focal, diffuse or mixed type, and to document his plan for angioplasty on the basis of the visual assessment. The number and length of stents planned for implantation for each patient should be also documented on the basis of visual estimation before the physiological measurements. Invasive coronary physiology assessment protocol: PressurewireX will be advanced distally to the investigated lesion(s) of a coronary artery. Resting and hyperemic average pressures will be determined in this distal position (in FFR mode). A resting manual pullback with 1-2 mm/s speed will be performed (in RFR mode) under simultaneous fluoroscopic control. The "store fluoro" option of the X-ray system allows the co-registration of the pressure drop(s) to the epicardial lesion(s) on the basis of the same time scale of the pullback and the stored fluoro. The use of marker(s) in the Quantien software can enhance the identification of the culprit interval(s) of the pressure pullback curve and the related angiographic details. A substudy of the register is planned to achieve extended physiological assessment in patients with the suspicion of microvascular disease in line with the latest ESC guideline stressing the role of microcirculatory dysfunction in the adverse outcome events in patients with non-significant coronary stenoses by FFR (class IIa, level B recommendation). According to the intracoronary average pressure values the pressure bounded CFR interval will be calculated (CFRpb). If the cut-off value CFR=2 lies inside the defined CFRpb interval, then a novel CFR calculation based on three-dimensional reconstruction and simple flow dynamic modelling will be performed to get the exact CFRp-3D value in order to diagnose or exclude microvascular disease. One simple possibility for the characterization of the microvasculature is to define the CFR/FFR index. This value below 2 indicate impaired microvascular vasodilator capacity. For getting more precise microvascular parameter, the flow modeling using the data of the 3D coronary reconstruction and the intracoronary pressure values will provide the microvascular resistance reserve (MRR). Offline 3D angiographic reconstruction will be performed from the selected two angiograms of good quality, with at least 25◦ difference in angle, using dedicated 3D software. Statistical Analysis: Normal distribution will be tested. Descriptive statistics are planned as mean and SD, median (interquartile range), or counts (%) as appropriate. Categorical variables will be compared with the Pearson χ2test. Correlation among variables will be determined by calculating Spearman ρ correlation coefficient. All analyses will be performed in Medcalc program.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 500
Est. completion date March 1, 2024
Est. primary completion date March 1, 2023
Accepts healthy volunteers No
Gender All
Age group 18 Years to 85 Years
Eligibility Inclusion Criteria: - At least one lesion on coronary artery branch greater than 2 mm in diameter assessed as 40-90% narrowing by visual estimation - Invasive intracoronary FFR and RFR measurement using the Quantien system according to clinical decision Exclusion Criteria: - Patients with acute coronary syndrome - Left main disease - Contraindication for adenosine - Coronary artery bypass graft on the investigated vessel - Severe renal insufficiency (estimated glomerular filtration rate <30 ml/min/1.73 m2) - Coronary angiography and pressure recordings not suitable for evaluation

Study Design


Related Conditions & MeSH terms


Locations

Country Name City State
Austria University Heart Center Graz, Division of Cardiology, Medical University Graz Graz
Hungary Department of Cardiology, Faculty of Medicine, University of Debrecen Debrecen
Hungary Bacs-Kiskun County Hospital Recruiting Kecskemet, Hungary, Kecskemét
Hungary Szabolcs - Szatmár - Bereg County Hospitals and University Teaching Hospital, András Jósa Teaching Hospital Nyíregyháza
Hungary Heart Institute, Medical School, University of Pécs Pécs
Hungary Invasive Cardiology Unit, Cardiology Center, University of Szeged Szeged

Sponsors (2)

Lead Sponsor Collaborator
Szabolcs - Szatmár - Bereg County Hospitals and University Teaching Hospital, András Jósa Teaching H Premier G Med Cardio Ltd.

Countries where clinical trial is conducted

Austria,  Hungary, 

References & Publications (11)

Beauman GJ, Vogel RA. Accuracy of individual and panel visual interpretations of coronary arteriograms: implications for clinical decisions. J Am Coll Cardiol. 1990 Jul;16(1):108-13. — View Citation

Gould KL, Lipscomb K, Hamilton GW. Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. Am J Cardiol. 1974 Jan;33(1):87-94. — View Citation

Gould KL. Does coronary flow trump coronary anatomy? JACC Cardiovasc Imaging. 2009 Aug;2(8):1009-23. doi: 10.1016/j.jcmg.2009.06.004. Review. Erratum in: JACC Cardiovasc Imaging. 2009 Sep;2(9):1146. — View Citation

Hoshino M, Yonetsu T, Sugiyama T, Kanaji Y, Hamaya R, Kanno Y, Hada M, Yamaguchi M, Sumino Y, Usui E, Hirano H, Horie T, Nogami K, Ueno H, Misawa T, Murai T, Lee T, Kakuta T. All Resting Physiological Indices May Not Be Equivalent - Comparison Between the Diastolic Pressure Ratio and Resting Full-Cycle Ratio. Circ J. 2020 Jun 25;84(7):1147-1154. doi: 10.1253/circj.CJ-19-1110. Epub 2020 Jun 4. — View Citation

Jeremias A, Davies JE, Maehara A, Matsumura M, Schneider J, Tang K, Talwar S, Marques K, Shammas NW, Gruberg L, Seto A, Samady H, Sharp A, Ali ZA, Mintz G, Patel M, Stone GW. Blinded Physiological Assessment of Residual Ischemia After Successful Angiographic Percutaneous Coronary Intervention: The DEFINE PCI Study. JACC Cardiovasc Interv. 2019 Oct 28;12(20):1991-2001. doi: 10.1016/j.jcin.2019.05.054. — View Citation

Knuuti J, Wijns W, Saraste A, Capodanno D, Barbato E, Funck-Brentano C, Prescott E, Storey RF, Deaton C, Cuisset T, Agewall S, Dickstein K, Edvardsen T, Escaned J, Gersh BJ, Svitil P, Gilard M, Hasdai D, Hatala R, Mahfoud F, Masip J, Muneretto C, Valgimigli M, Achenbach S, Bax JJ; ESC Scientific Document Group. 2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes. Eur Heart J. 2020 Jan 14;41(3):407-477. doi: 10.1093/eurheartj/ehz425. Erratum in: Eur Heart J. 2020 Nov 21;41(44):4242. — View Citation

Neumann FJ, Sousa-Uva M, Ahlsson A, Alfonso F, Banning AP, Benedetto U, Byrne RA, Collet JP, Falk V, Head SJ, Jüni P, Kastrati A, Koller A, Kristensen SD, Niebauer J, Richter DJ, Seferovic PM, Sibbing D, Stefanini GG, Windecker S, Yadav R, Zembala MO; ESC Scientific Document Group. 2018 ESC/EACTS Guidelines on myocardial revascularization. Eur Heart J. 2019 Jan 7;40(2):87-165. doi: 10.1093/eurheartj/ehy394. Erratum in: Eur Heart J. 2019 Oct 1;40(37):3096. — View Citation

Patel MR, Calhoon JH, Dehmer GJ, Grantham JA, Maddox TM, Maron DJ, Smith PK. Correction to: ACC/AATS/AHA/ASE/ASNC/SCAI/SCCT/STS 2017 Appropriate Use Criteria for Coronary Revascularization in Patients With Stable Ischemic Heart Disease. J Nucl Cardiol. 2018 Dec;25(6):2191-2192. doi: 10.1007/s12350-018-1292-x. — View Citation

Svanerud J, Ahn JM, Jeremias A, van 't Veer M, Gore A, Maehara A, Crowley A, Pijls NHJ, De Bruyne B, Johnson NP, Hennigan B, Watkins S, Berry C, Oldroyd KG, Park SJ, Ali ZA. Validation of a novel non-hyperaemic index of coronary artery stenosis severity: the Resting Full-cycle Ratio (VALIDATE RFR) study. EuroIntervention. 2018 Sep 20;14(7):806-814. doi: 10.4244/EIJ-D-18-00342. — View Citation

Van't Veer M, Pijls NHJ, Hennigan B, Watkins S, Ali ZA, De Bruyne B, Zimmermann FM, van Nunen LX, Barbato E, Berry C, Oldroyd KG. Comparison of Different Diastolic Resting Indexes to iFR: Are They All Equal? J Am Coll Cardiol. 2017 Dec 26;70(25):3088-3096. doi: 10.1016/j.jacc.2017.10.066. — View Citation

Warisawa T, Cook CM, Howard JP, Ahmad Y, Doi S, Nakayama M, Goto S, Yakuta Y, Karube K, Shun-Shin MJ, Petraco R, Sen S, Nijjer S, Al Lamee R, Ishibashi Y, Matsuda H, Escaned J, di Mario C, Francis DP, Akashi YJ, Davies JE. Physiological Pattern of Disease Assessed by Pressure-Wire Pullback Has an Influence on Fractional Flow Reserve/Instantaneous Wave-Free Ratio Discordance. Circ Cardiovasc Interv. 2019 May;12(5):e007494. doi: 10.1161/CIRCINTERVENTIONS.118.007494. — View Citation

* Note: There are 11 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary Concordance of visual estimation and functional assessment Comparison of the visual estimate of coronary lesions and the functional severity of the stenosis assessed by RFR pullback both on lesion- and vessel levels. Baseline, before invasive functional assessment (The visual assessment is performed after the completion of the diagnostic coronary angiography, while the functional evaluation is recorded after the intracoronary physiological measurements)
Primary Characterization the coronary vessel for predominantly focal/diffuse or mixed type of the disease according to visual versus RFR pullback determination. Focal disease: ?RFR >0.05 for <25mm segment length (>0.002/mm) Diffuse disease: ?RFR >0.05 for >25mm segment length If both focal and diffuse criteria are fulfilled in the investigated vessel, then mixed type disease is diagnosed Baseline, before invasive functional assessment (The visual assessment is performed after the completion of the diagnostic coronary angiography, while the functional evaluation is recorded after the intracoronary physiological measurements)
Primary Evaluation of the concordance of the therapeutic strategies (conservative/PCI/CABG) on the basis of visual evaluation versus RFR measurements. Comparison of the rate of indication for the individual therapeutic strategies (conservative/PCI/CABG) by visual estimation and RFR measurements. Baseline, pre-intervention (Theoretical clinical decision is made after the visual assessment of the diagnostic coronary angiography, while the final decision is made after the functional evaluation by intracoronary physiological measurements)
Secondary In cases when the operator decides stent implantation, the planned number of stents also to be investigated according to the visual estimation versus RFR measurement. Comparison of the planned number of stents on the basis of visual estimation versus RFR measurement Baseline, pre-intervention (Theoretical clinical decision is made after the visual assessment of the diagnostic coronary angiography, while the final decision is made after the functional evaluation by intracoronary physiological measurements)
Secondary In cases when the operator decides stent implantation, the total length of the planned stent(s) also to be investigated according to the visual estimation versus RFR measurement. Comparison of the length of the planned stent(s) on the basis of visual estimation versus RFR Baseline, pre-intervention (Theoretical clinical decision is made after the visual assessment of the diagnostic coronary angiography, while the final decision is made after the functional evaluation by intracoronary physiological measurements)
See also
  Status Clinical Trial Phase
Recruiting NCT05133843 - Complete Functional Assessment of Intermediate Coronary Artery Stenosis Before and After Transcatheter Aortic Valve Implantation (TAVI) in Patients With Severe Symptomatic Aortic Valve Stenosis N/A
Completed NCT01205776 - EXCEL Clinical Trial N/A
Completed NCT01182428 - XIENCE V: SPIRIT WOMEN Sub-study Phase 4
Completed NCT00739466 - Biorest Liposomal Alendronate With Stenting sTudy (BLAST) Phase 2
Completed NCT01332591 - Multivessel Disease Diagnosed at the Time of PPCI for STEMI: Complete Revascularization Versus Conservative Strategy. N/A
Completed NCT01310309 - EXecutive Registry: Evaluating XIENCE V® in a Multi Vessel Disease Phase 4
Completed NCT00531011 - EXecutive RCT: Evaluating XIENCE V® in a Multi Vessel Disease Phase 4
Not yet recruiting NCT06052670 - Functional Diagnostic Accuracy of Ultrasonic Flow Ratio in Assessment of Coronary Artery Lesions
Completed NCT05509296 - Compare the Effectiveness and Safety of Two Different Kinds of Cutting Balloon in Coronary Artery Disease N/A
Not yet recruiting NCT05393882 - Impact of Cholesterol Level on Long-term Coronary Bypass Graft Patency
Recruiting NCT06397820 - Relation Between AI-QCA and Cardiac PET
Active, not recruiting NCT01960504 - First in Man Study of the DREAMS 2nd Generation Drug Eluting Absorbable Metal Scaffold (BIOSOLVE-II) N/A
Completed NCT01721096 - XIENCE PRIME Japan Post-Marketing Surveillance (PMS)
Active, not recruiting NCT01342822 - Trial to Assess the Everolimus-Eluting Coronary Stent System (PROMUS Element) for Coronary Revascularization Phase 4
Completed NCT01205789 - EXCEL Clinical Trial (Universal Registry) N/A
Recruiting NCT05532605 - Effects of Mindfulness Based Therapy on Illness and Depression in Cardiac Rehab Phase-i N/A
Completed NCT02066623 - Observational Study to Evaluate Short and Long-term Safety of the ABSORB Scaffold
Not yet recruiting NCT02946320 - Optimal Predilatation Technique for BVS Implantation Phase 3
Completed NCT01249027 - XIENCE V Everolimus Eluting Coronary Stent System (EECSS) China: Post-Approval, Single-Arm Study
Terminated NCT01136915 - Kidney Damage In Patients With Severe Fall In eGFR Phase 4