Coronary Artery Disease Clinical Trial
— LARGE-ONEOfficial title:
LARGE-ONE: A Prospective, Multicenter, Randomized Controlled Trial of the Use of Drug-coating Balloons(DCB) or Drug-eluting Stents(DES) in the Treatment of Large Diameter Coronary Atherosclerotic Lesions
For the treatment of primary large-diameter coronary atherosclerosis through percutaneous coronary intervention (PCI), the use of a drug balloon (DCB) is not inferior to the placement of a drug-eluting stent (Firehawk™ family). * Large-diameter vessels were defined as vessels with a diameter of ≥3.00 mm and ≤ 4.0mm
Status | Recruiting |
Enrollment | 134 |
Est. completion date | January 2026 |
Est. primary completion date | January 2025 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 75 Years |
Eligibility | Inclusion Criteria: CI1. Age of subject 18-75 years old; CI2. The subject (or legal guardian) understands and provides written informed consent to the test requirements and treatment procedures prior to performing any specific tests or procedures in the study; CI3. The subject is suitable for percutaneous coronary intervention (PCI); CI4. The subject had symptomatic coronary artery disease with objective evidence or asymptomatic ischemia; CI5. Subject is willing to submit to all subsequent evaluations required by the test protocol Angiogragh Inclusion AI1. At Maximum 2 target lesions with stenosis =50%, located in no more than 2 vessels with a visual reference vessel diameter (RVD) of =3.00 mm and =4.00 mm; AI2. The length of the target lesion must be=35 mm (visually) and can be covered by one study stent or drug balloon; AI3. The first target lesion must be successfully predilated/pretreated without: 1. Vascular tears affecting hemodynamics (TIMI blood grade =2); 2. Coronary dissection classified as D, E and F(ARC); 3. Residual stenosis > 30% after lesion preparation; Note: If Type C dissection occurs at lesion predilation/preparation, clinical investigators will determine whether the target lesion can be included based on the comprehensive situation of blood flow and patients risks . Type C dissection will be excluded from the OCT subgroup considering the risk of dissection extension for OCT operation. AI4. The anatomical conditions of the coronary artery were appropriate, and the study instrument could be transported to the appropriate location of the target lesion. Exclusion Criteria: CE1. Subjects with clinical symptoms and/or ECG findings consistent with the diagnosis of acute ST-segment elevation myocardial infarction (STEMI) within 7 days; CE2. Subject is known to be allergic to contrast agents (which cannot be fully pretreated) and/or concomitant medications required by the stent system or protocol (e.g., cobalt-chrome, platinum-chrome, stainless steel, rapamycin, paclitaxel and similar configuration compounds, drug coating carrier components, all P2Y12 receptor inhibitors, aspirin, etc.); CE3. Planned surgical treatment within 6 months after baseline surgery; CE4. Severe heart failure (NYHA Grade IV) or left ventricular ejection fraction <30% (ultrasound or left ventricular contrast); CE5. Previous renal impairment: serum creatinine >2.0mg/dL; Or on dialysis; CE6. Previous bleeding events (BARC III or V); CE7. Subject is receiving or indication of long-term anticoagulant therapy ; CE8. Subject has any of the following conditions (baseline assessment) : - Other serious medical conditions that reduce subjects' life expectancy to less than 13 months (e.g., cancer, congestive heart failure); - Subject has a current substance abuse problem (e.g., alcohol, cocaine, heroin, etc.); - Subject plans to undergo surgical/intervention procedures that may result in non-compliance with protocol or confusing data interpretation; CE9. Subject has a history of bleeding tendency, coagulation disorders or refusal of blood transfusion; CE10. The subject is participating in a clinical trial of another investigational drug or device that does not meet its primary endpoint; CE11. Subjects are scheduled to participate in another investigational drug or device clinical trial within 13 months of baseline procedure; CE12. Subjects who intend to be pregnant within 13 months of baseline procedure (fertile and sexually active women should consent to use a reliable contraceptive method from screening to 13 months after baseline surgery); CE13. Subjects are pregnant or breastfeeding (fertile women with pregnancy possibility should undergo a pregnancy test within 7 days prior to baseline surgery). Angiogragh Exclusion AE1. Plan to treat 3 or more target lesions; AE2. Plan to treat more than 2 major epicardial vessels; AE3. A single lesion to be treated cannot be covered by a single stent or a single drug balloon; AE4. The subject had two target lesions in the same target vessel, and the distance between the two target lesions was =15mm (visual observation); AE5. Target lesions were located in the left main trunk; AE6. Target lesions were located within 3mm of the initial segment of the left anterior descending artery (LAD) or left circumflex artery (LCX). AE7. Target lesions were located in a saphenous vein, artery or artificial bypass graft; AE8. Target lesions need to be treated through a saphenous vein, artery or artificial bypass graft ; AE9. Target lesion blood flow grade of TIMI 0/1 before guide wire passes through ; AE10. Treatment of target lesions involves multi-stent strategy in complex lesions (e.g., bifurcated lesions require more than one stent); AE11. Target lesions involve previously in-stent restenosis lesions or overlap with previously implanted stents; AE12. Subject has unprotected left main coronary artery disease (>50% diameter stenosis); AE13. Subjects have received PCI for any type of target lesion (e.g., balloon dilation, stent placement, balloon dissection, etc.) within 12 months before baseline; AE14. Presence of thrombus or possible thrombus in the target lesion (visual); AE15. The target lesions were moderate to severe calcification lesions. |
Country | Name | City | State |
---|---|---|---|
China | Jining Medical University Affiliated Hospital | Jining | Shandong |
Lead Sponsor | Collaborator |
---|---|
Shanghai MicroPort Medical (Group) Co., Ltd. |
China,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Value of Luminal loss at 13month post procedure | defined as the difference between the minimum lumen diameter in the lesion segment immediately after use of the study instrument and the minimum lumen diameter at 13 months angiographic follow up . | 13 months | |
Secondary | Rate of Target Lesion Failure(TLF) | defined as the composite of cardiac death, target vessel-related myocardial infarction (MI)*, or ischemia-driven target lesion revascularization (TLR) | 30 days, 6 months, 1and 2 years | |
Secondary | Rate of Major Adverse Cardiac Events(MACE ) | The composite of cardiac death, any MI or ischemia-driven TLR, and stent thrombosis myocardial infarction (MI)*, or ischemia-driven target lesion revascularization (TLR) | 30 days, 6 months, 1and 2 years | |
Secondary | Value of Neointimal Volume: | the total volume bounded by the stent and the lumen within the segment of interest. It can be calculated using the formula: [= Stent Volume - Lumen Volume] | 3 months post procedure | |
Secondary | Value of Stent Volume | Based on Simpson's rule, the stent volume is calculated as the total volume bounded by the stent within the segment of interest. In the absence of neointimal hyperplasia, malapposition, and tissue protrusion, the stent volume corresponds to the lumen volume. | 3 months post procedure | |
Secondary | Value of Lumen Volume | Based on Simpson's rule, the total volume bounded by the lumen within the segment of interest. | 3 months post procedure |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |