Coronary Artery Disease Clinical Trial
Official title:
Quantification and Determinants of Occupational Xray Scatter Radiation Exposure of Operators and Assistants During Coronary Procedures - The Occupational SCAtter Radiation Registry
During diagnostic and interventional coronary procedures scatter radiation exposure is recorded with live-dosimeters at pre-specified anatomic regions of operators and sterile assistants. Scatter radiation data is correlated with detailed Xray exposure data and technical details of the procedure. The purpose of the registry is: 1. to establish scatter radiation reference values based on a large number of representative cath-lab procedures 2. to identify technical and clinical factors predisposing for high scatter radiation exposure, 3. to evaluate advanced radiation protection devices in clinical routine.
Patients scheduled for diagnostic or interventional coronary procedures provide written informed consent for participating in the observational OSCAR Registry. During the corresponding procedures, scatter radiation exposure of operators and sterile assistants is recorded using Unfors RaySafe i3 digital live dosimeters (Unfors RaySafe AB, Billdal, Sweden) at 3 locations of the operator (1-frontal head at eye level, 2-left lateral head, 3-below the left shoulder) and at 2 locations of the sterile assistant (1-left neck and 2-below the left shoulder). Raw data is collected in a central database and correlated with patient properties (age, BMI) and detailed Xray exposure data: - Total dose-area product (DAP, unit of measure: Gy*cm2) - Number of Xray image series - Number of Images - Radiation duration (Unit of measure: Seconds) - Air kinetic energy released per unit mass (Kerma) Technical details of the procedure - Access site, - Clinical setting: acute or elective - Number of catheters used during procedure - Number of guidewires used during procedure - Number of stents implanted during procedure - Cumulative stent length (Unit of measure: mm) - Use of rotational imaging - Use of intracoronary pressure-wire - Use of optical coherence tomography (OCT) - Presence of bypass-vessels - Any occurrence of complications The purpose of the trial is to establish a large foundation of intra-procedural scatter radiation data from representative coronary procedures procedures enabling our group to 1. Establish scatter radiation reference values based on a large number of representative cath-lab procedures 2. Identify technical and clinical factors predisposing for high staff scatter radiation exposure 3. Evaluate advanced radiation protection devices in clinical routine. This includes: - Additional ceiling-suspended lead-shielding - Ceiling-suspended radiation protection devices like the "Zero-Gravity"-System (TIDI Medical Products, Neenah, WI, USA) - Patient lead-covers. The study was submitted to and approved by the federal Ethics Committee Salzburg (reference number ECS 1069/2021). ;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
| Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
| Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
| Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
| Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
| Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
| Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
| Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
| Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
| Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
| Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
| Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
| Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
| Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
| Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
| Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
| Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
| Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
| Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
| Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |