Coronary Artery Disease Clinical Trial
Official title:
Correlation Between Arterial Stiffness and Aortic-to-radial Pressure Gradient After Cardiopulmonary Bypass
This study will examine whether pre-operative, non-invasive arterial stiffness measurements can be used to predict which patients will develop an aortic-to-radial pressure gradient after coronary artery bypass graft (CABG) surgery. A previous small study by Kanazawa, et al. demonstrated in patients who developed an aortic-to-radial pressure gradient after CABG surgery, the pulse wave velocity (PWV) was higher in the aorta and decreased when moving toward the radial artery. In the patients who did not develop a pressure gradient, the PWV started lower in the aorta and increased when moving towards the periphery. The purpose of this investigation is to examine whether pre-operative PWV measurements can be used to identify patients who will develop an aortic to radial pressure gradient after CABG surgery. Applanation tonometry will be performed on the right carotid and femoral arteries to assess carotid-femoral pulse wave velocity, a surrogate for aortic stiffness. (SphygmoCor system, AtCor Medical, Sydney, Australia). The measurement will be obtained before induction of general anesthesia in the presurgical area. Also in the presurgical area, a non-invasive cardiac output (CO) measurement will be obtained by using the ICON Device (Osypka Medical, La Jolla, California). This CO value will be used to compare to the CO values obtained invasively in the operating room.
The purpose of the study is determine if there is a relationship between pre-operative vascular characteristics including, carotid-femoral pulse wave velocity (cfPWV), Augmentation Index(AI) and central aortic pressure, and the development of a pressure gradient between the aorta and radial artery after cardiopulmonary bypass. The procedures necessary to achieve the desired outcomes are as follows. The first measurement made by the research team will be pre-operative cardiac output (CO) measurement. The ICON device is a non-invasive device that measures CO, or the amount of blood that your heart pumps per minute. This device utilizes four stickers that are attached to skin, two on the left side of the neck and two located on the left side of the chest. These stickers function similarly to electrocardiogram (EKG) stickers that measure the electrical activity of your heart. After attachment of the stickers, the ICON device will be used to make a measurement of CO, which takes 1-2 minutes. After the measurement, the stickers will be removed and the ICON device will not be used again in the study. Secondly, pre-operative cfPWV, AI, and central aortic pressure measurements will be made. The Sphygmocor device will be utilized to make the pre-operative cfPWV, AI and central aortic pressure measurements. First, the AI measurements will be made using a non-invasive blood pressure cuff placed on the right arm. The patient's blood pressure will be measured twice in a row with this special blood pressure cuff. The blood pressure cuff on the right arm will be removed and then a cuff will be placed around the right thigh. Measurements will be made with a paper ruler from the patient's neck to the cuff on their leg. To make the cfPWV measurements, the cuff on the thigh will inflate while a pressure probe will be placed on the skin of the patient's right neck. Four measurements of cfPWV will be made with this technique. The intraoperative central aortic pressure measurement will be accomplished with the help of the cardiothoracic surgeon. The surgeon will place a catheter in the aorta as part of the coronary artery bypass grafting surgery. This catheter will be connected to the artificial heart-lung machine. Prior to turning on the heart-lung machine, the pressure in the aorta will be measured with this catheter. This is the standard of care for this type of surgery and will not delay the surgery. After the artificial heart-lung machine is turned off but before the catheter is removed from the aorta, the pressure will once again be measured. In order to measure intraoperative CO values, we will utilize the pulmonary artery (PA) catheter that was placed at the beginning of the surgery.. The patient will have a catheter placed in the right side of the neck that will travel through the heart and into a branch of the artery that goes from the heart to the lungs. This catheter will have the ability to measure the amount of blood that is pumped from the heart per minute. At the same times that the pressure in the aorta is measured (as above), the amount of blood that is pumped from the heart per minute will be measured. Lastly measurement of peripheral artery blood pressure will be accomplished with a right radial arterial catheter. Prior to the start of surgery, the patient will receive a special catheter in the radial artery of their right arm. This is the standard of care for blood pressure monitoring in this type of surgery. At the same times during the surgery that the pressure is being measured from the aortic catheter, the pressure will be measured from the catheter in the right radial artery. ;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
| Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
| Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
| Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
| Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
| Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
| Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
| Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
| Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
| Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
| Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
| Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
| Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
| Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
| Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
| Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
| Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
| Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
| Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
| Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |