Coronary Artery Disease Clinical Trial
Official title:
Assessment and Prognostic Significance of Global Myocardial Perfusion Reserve Using Coronary Sinus Flow Measurements During Regadenoson Stress Cardiac Magnetic Resonance
The aim of this study is to assess whether myocardial perfusion reserve, measured during routine clinically ordered regadenoson stress cardiac magnetic resonance (CMR) has prognostic value in predicting adverse cardiovascular events. Myocardial perfusion reserve will be measured with CMR by assessing blood flow through the coronary-sinus - the primary vein in the heart.
Myocardial perfusion reserve is the ratio of global myocardial blood flow at stress vs. rest.
Traditionally, it has been measured non-invasively using quantitative positron emission
tomography (PET) or cardiac magnetic resonance (CMR). Several recent studies have suggested
that measurement of myocardial perfusion reserve provides significant additive prognostic
information during stress perfusion imaging in patients with known or suspected coronary
artery disease. Myocardial perfusion reserve depends not only on trans-stenotic pressure
gradient of the epicardial arteries and thus stenosis severity but even more on the ability
of the coronary microvasculature (especially the pre-arterioles) to dilate. Therefore,
coronary microvascular dysfunction, which impairs pre-arteriolar function, reduces myocardial
perfusion reserve independently of the presence of epicardial coronary stenosis. Hence, the
ability to measure myocardial perfusion reserve allows a more comprehensive assessment of the
entire coronary circulation, beyond the current paradigm of the epicardial arteries.
However, both PET and current CMR techniques are cumbersome, and in the case of PET require
radiation as well as on-site Rubidium-82 generators. Therefore, they are challenging for
routine clinical practice and have been limited to specialized research centers. An
alternative, simple CMR method for measurement of myocardial perfusion reserve by quantifying
change in coronary sinus flow has been described. The coronary sinus drains approximately 96%
of total myocardial blood flow and provides a potentially convenient location for measurement
of global myocardial blood flow. This method has been validated against both invasive and PET
techniques. The investigators hypothesized that measurement of coronary sinus flow at stress
and rest may provide a simple and rapid assessment of myocardial perfusion reserve during
regadenoson stress perfusion CMR.
This study will use phase contrast images obtained from patients during their clinically
indicated CMR stress study to calculate myocardial perfusion reserve as the ratio of maximum
myocardial blood flow to baseline blood flow - at the coronary sinus. Coronary sinus flow
will be calculated by post-processing of images after the patient has left the scanner. In
brief, the contour of the coronary sinus will be traced on the flow images throughout the
cardiac cycle. Coronary sinus flow is calculated by integrating the momentary flow rate
values from each cardiac phase over the entire cardiac cycle and multiplying by the mean
heart rate during the acquisition. Patients will be followed for the occurrence of major
adverse cardiac events (death, myocardial infarction, late revascularization, hospitalization
for heart failure or unstable angina).
;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
| Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
| Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
| Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
| Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
| Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
| Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
| Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
| Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
| Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
| Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
| Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
| Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
| Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
| Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
| Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
| Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
| Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
| Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
| Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |