Clinical Trials Logo

Clinical Trial Summary

The purpose of this clinical research study is the design of a novel modular hybrid system extracorporeal circulation circuit for open heart procedures that could easily be converted from a closed to a semi-closed circuit according to the indication. This could expand the potential of minimal extracorporeal circulation and could ultimately become the new standard circuit in performing every type of cardiac surgery.


Clinical Trial Description

Development of cardiopulmonary bypass circuit (heart-lung machine) is considered as a landmark breakthrough in cardiac surgery, greatly promoting treatment of cardiovascular diseases. Since 1953, when the first operation under cardiopulmonary bypass was performed and for almost 6 decades, little progress has been made in the direction of improving cardiopulmonary bypass technology. However, evolution is feasible. The proposed research project challenges the traditional belief that conventional cardiopulmonary bypass should be considered as "state of the art" technology by deducting solid evidence towards extended use of the novel minimal extracorporeal circulation circuit, which is related to an improved outcome through multiple studies. Research methodology is based on analyzing laboratory and clinical data obtained through implementing the standard and the novel technology. In order to provide solid evidence on the comparative effectiveness of both therapies, it combines analysis of clinical and laboratory data with data related to cost and quality of life. Thus, it assesses novel technology from a global perspective and the evidence obtained would be considered robust. The ultimate purpose of the research proposal is the design of a modular hybrid system, that could easily convert from form a closed to a semi-closed circuit according to the indication, that could expand the potential of minimal extracorporeal circulation and could ultimately become the new standard circuit in performing every type of cardiac surgery. The term modular refers to an additionally mounted, clamped-off venous reservoir which allows to run the system as an open circuit in case of anticipated volume loss (ie bleeding, complex procedures, long bypass run). This measure follows the proverb 'always expect the unexpected' and offers the clinical practitioner an additional safety margin in case of unexpected intraoperative events. Unique design of this circuit would offer the opportunity of reducing cost, while at the same time improving clinical outcome. Preliminary design of this circuit, performed in our institution, is presented schematically in the appendix. After completion of the study protocol the designed circuit will be patented. Our institution has already performed extensive research and has gained international reputation as a training centre on minimal extracorporeal circulation. Design of such a circuit could promote further research funded by the medical industry. Considering the number of cardiac surgical procedures performed every day worldwide, this evolution is greatly ambitious and could be characterized as a major breakthrough in the field of cardiac surgery opening up new horizons in the field of cardiovascular research. It would also exert a positive effect on global healthcare affecting lives of millions of people suffering from cardiovascular disease. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02000544
Study type Interventional
Source AHEPA University Hospital
Contact
Status Completed
Phase N/A
Start date October 2013
Completion date December 2020

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A