Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT05236790
Other study ID # 21.305
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date June 20, 2022
Est. completion date June 20, 2023

Study information

Verified date September 2023
Source Centre hospitalier de l'Université de Montréal (CHUM)
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The investigators hypothesize that the clinical implementation of an AI system is an optimal tool to monitor, audit and improve the detection and classification of polyps during colonoscopy. The purpose of this prospective clinical cohort study is to evaluate the performance of the SCALE-EYE virtual scale for measuring polyp size when used during live colonoscopies. The investigators also wish to evaluate CAD-eye for detection and classification of polyp histology. It is hypothesized that CAD-eye and SCALE-EYE can function in real-time practice with high accuracy.


Description:

Detailed Description: This study will be conducted in several phases: phase 1 will evaluate the feasibility of using CAD-eye in real-time practice, training endoscopists to work with this platform, obtaining preliminary data on relative size measurement accuracy when using scale eye, testing feasibility of fresh polyp specimen size measurement and determining the sample size and reference standard for evaluating SCALE-EYE during the subsequent phases of the study in randomized controlled trials. Phase 2 will evaluate relative size measurement accuracy of SCALE-EYE compared to visual size estimation and CADe/CADx performance in a randomized controlled trial. Scale-eye will further be validated through video-based analysis comparing different size measurement methods (scale eye, snare, forceps, visual assessment) with different groups of endoscopists (experts, staff gastroenterologists, trainees evaluating videos showing video sequences that show the polyps either with scale eye, visual or instrument information. Furthermore, fresh specimen size measurement and pathology-based size (including different ways to prepare specimens for pathology sectioning) will be evaluated for agreement between size measurement methods and tissue shrinkage effects. Phase 3 will evaluate relative size measurement accuracy of SCALE-EYE compared to snare-based size estimation. Eligible patients will be adults (aged 45 to 80 years) referred to CHUM for diagnostic, screening or surveillance colonoscopy. Patients will undergo colonoscopies using CAD-eye, and the size of all polyps detected will be estimated by different subjective and objective methods. All polyp size measurements will be videorecorded. Video recordings with different measurement instruments (forceps, snare, scale eye, visual assessment) will be assessed with different groups of endoscopists (experts, staff gastroenterologists, trainees) for size measurements through online video presentations in a randomized order. The main results of this study are to evaluate the relative accuracy of SCALE-EYE for polyp size estimation and the adenoma detection rates, sensitivity, specificity, NPV for CAD-eye for polyp detection and classification. We will also calculate other characteristics of CAD-eye and SCALE-EYE tests, the rate of divergence and/or agreement between subjective and objective methods of polyp size estimation, the agreement between surveillance intervals based on optical diagnosis by CAD-eye and pathological findings, and the false positive rate and latency for polyp detection.


Recruitment information / eligibility

Status Completed
Enrollment 348
Est. completion date June 20, 2023
Est. primary completion date June 20, 2023
Accepts healthy volunteers No
Gender All
Age group 45 Years to 80 Years
Eligibility Inclusion Criteria: - indication of undergoing a screening, surveillance, or diagnostic colonoscopy - Age 45-80 years - Signed informed consent Exclusion Criteria: - Known inflammatory bowel disease (IBD) - Active Colitis - Poor general health, defined as an American Society of Anesthesiologists (ASA) physical status class >3 - Coagulopathy - Familial polyposis syndrome - Emergency colonoscopies - Poor bowel preparation score defined as the total Boston bowel preparation score <6 and the right-segment score <2. For per-polyp analysis: 1. For optical diagnosis (CADx) we will exclude all polyps >5mm. We will also exclude sessile serrated polyps and traditional serrated adenomas from the analysis as CADx can only differentiate between adenomas and hyperplastic polyps. 2. For polyp size measurement (SCALE-EYE), we will exclude all polyps resected in several pieces (piecemeal resection), or specimens damaged (e.g., fractured) during the suction and retrieval process, submillimeter polyps too small for measurement after resection. Polyps after the 5th resected polyp in a single piece will be excluded to reduce the time associated with the procedure. 3. For polyp detection (CADe) we will not exclude any polyp from the analysis.

Study Design


Related Conditions & MeSH terms


Intervention

Diagnostic Test:
Detection and classification and size measurement of polyp by Artificial Intelligence (Cad eye) and the Scale Eye
Detection and classification and size measurement of polyp by Artificial Intelligence (CADeye) and Scale Eye This study will be conducted in multiple phases: phase 1 (pilot phase, n=40 polyps, about 60 patients) to evaluate the feasibility of applying Scale Eye in real-time practice, training endoscopists to work with CADe and CADx and determining the sample size and reference standard to evaluate SCALE-EYE during the second phase of the study (randomized controlled trial), phase 2 will evaluate the performance of SCALE-EYE and CAD-eye in real-time practice. The sample size for phase 2 (RCT comparing visual with scasle eye) will be based on the pilot data allowing to compare relative accuracy of size measurement with scale eye versus visual size estimation. After completion of phase 2 later phases will use instruments such as snare and/or forceps as reference measurement devices compared to relative accuracy of measurement when using scale eye.

Locations

Country Name City State
Canada Centre Hospitalier Universitaire de Montréal Montréal Quebec

Sponsors (1)

Lead Sponsor Collaborator
Centre hospitalier de l'Université de Montréal (CHUM)

Country where clinical trial is conducted

Canada, 

Outcome

Type Measure Description Time frame Safety issue
Primary Evaluation of the Scale-Eye to compare the relative accuracies of SCALE-EYE size measurement, visual size estimation or size estimation based on a standard polypectomy snare for colorectal polyps during real-time colonoscopies with measurement of viable specimens by a Vernier caliper as reference standard. Relative accuracy is defined as "1-[(ScaleEye measurement - gold standard measurement)/gold standard measurement] x100". Scale: 0-100. Higher score is a better outcome. 30 days
Primary Evaluation of CADe function compare the adenoma detection rate between the CAD-eye-assisted colonoscopy and standard colonoscopy (i.e., detecting adenomas only by endoscopists) 30 days
Primary Evaluation of CADx function evaluate the accuracy, sensitivity, specificity, positive and negative predictive value of CADx for classifying 1-5 mm polyp histology into neoplastic and non-neoplastic compared with the histopathology outcomes as the reference standard 30 days
Secondary Agreement and discrepancy between SCALE-EYE and other measurement calculate the agreement and discrepancy between SCALE-EYE and other measurement methods 30 days
Secondary Video-based assessments compare in video-based assessments with different endoscopists (expert level, staff GI, surgeons, trainees the relative size measurements accuracy of scale eye with visual and instrument based (snare and/or forceps) size measurement accuracy 30 days
Secondary CADe sensitivity in polyp detection evaluate the sensitivity of the CAD-eye in combination with adjunct methods for real-time detecting colorectal polyps compared with standard colonoscopy 30 days
Secondary CADe function: proportion of polyps detected to evaluate the proportion of polyps detected by the CAD-eye in combination with adjunct methods 30 days
Secondary Evaluation of CADx function compare the accuracy, sensitivity, specificity, positive and negative predictive value of CADx for classifying 1-5 mm polyp histology to that of using human decision based on CADx suggestion Through study completion, estimation: 3 months
Secondary CADx proportion of polyp histology non-evaluable calculate the proportion of 1-5 mm polyps, CADx can not suggest histology (in the intervention arm, please refer to the randomization section), while endoscopists can suggest histology with high confidence, or vice versa 30 days
Secondary CADx diagnostic uncertainty evaluate diagnostic uncertainty of the current CADx module when predicting the pathology of colorectal polyps 30 days
Secondary 3D scanning assessment evaluation of the relative accuracy of 3D scanned polyps compared to measurement of viable specimens by a Vernier caliper as reference standard. Relative accuracy is defined as "1-[(ScaleEye measurement - gold standard measurement)/gold standard measurement] x100". Scale: 0-100. Higher score is a better outcome. 30 days
Secondary Histologic size assessment evaluation of the relative accuracy of histologic size measurement compared to measurement of viable specimens by a Vernier caliper as reference standard. Relative accuracy is defined as "1-[(ScaleEye measurement - gold standard measurement)/gold standard measurement] x100". Scale: 0-100. Higher score is a better outcome. 30 days
See also
  Status Clinical Trial Phase
Completed NCT04192565 - A Prospective Investigation of the ColubrisMX ELS System N/A
Completed NCT04516785 - Reducing Colonoscopies in Patients Without Significant Bowel Disease
Recruiting NCT05381792 - Serial Gut Microbiome and Bacterial Gene Markers Changes After Endoscopic Resection of Colorectal Advanced Neoplasia
Withdrawn NCT05606081 - Predicting Risk for Post-polypectomy Colorectal Cancer N/A
Recruiting NCT05576506 - Application of Hyperspectral Imaging Analysis Technology in the Diagnosis of Colorectal Cancer Based on Colonoscopic Biopsy
Active, not recruiting NCT03796884 - Linaclotide in Treating Patients With Stages 0-3 Colorectal Cancer Phase 2
Completed NCT05508503 - A Study on a Blood-based Dual-target Test for CRC Detection
Recruiting NCT02935049 - Evaluation of the Resection of Adenoma and Colic Adenocarcinoma by EMR Piecemeal or EMR/ESD Hybrid Technique N/A
Completed NCT05477836 - Feasibility and Safety of MiWEndo-assisted Colonoscopy N/A
Active, not recruiting NCT05754229 - Accuracy of Real Time Characterization in Artificial Intelligence-assisted Colonoscopy N/A
Active, not recruiting NCT05740137 - Adenoma Detection Rate in Artificial Intelligence-assisted Colonoscopy N/A
Completed NCT03234725 - Analysis of New Endoscopic Features and Variable Stiffness in Colonoscopy: Prospective Randomised Trial
Completed NCT05913453 - Technical Failure During Colorectal Endoscopic Full Thickness Resection (EFTR): The "Through Thick and Thin" Study
Recruiting NCT05261932 - Research on Endoscopic Precision Biopsy.
Completed NCT02521727 - To Investigate Risk of Colorectal Neoplasms in First-degree Relatives of Patients With Non-advanced Adenomas
Completed NCT02226185 - Study of Berberine Hydrochloride in Prevention of Colorectal Adenomas Recurrence Phase 2/Phase 3
Completed NCT00298545 - Effect of Vitamin D and Calcium on Genes in the Colon Phase 1
Completed NCT03268655 - Ginger and Gut Microbiome (GINGER) N/A
Active, not recruiting NCT04952129 - Optimal Selenium for Bowel Polyps (OSCAR) Phase 1
Recruiting NCT04444908 - Development and Validation of an Artificial Intelligence-assisted Strategy Selection System for Colonoscopy Cleaning