Colorectal Adenoma Clinical Trial
Official title:
Performance Evaluation of CAD-EYE and SCALE-EYE for Detection, Classification, and Measurement of Colorectal Polyps: a Prospective Study
NCT number | NCT05236790 |
Other study ID # | 21.305 |
Secondary ID | |
Status | Completed |
Phase | N/A |
First received | |
Last updated | |
Start date | June 20, 2022 |
Est. completion date | June 20, 2023 |
Verified date | September 2023 |
Source | Centre hospitalier de l'Université de Montréal (CHUM) |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The investigators hypothesize that the clinical implementation of an AI system is an optimal tool to monitor, audit and improve the detection and classification of polyps during colonoscopy. The purpose of this prospective clinical cohort study is to evaluate the performance of the SCALE-EYE virtual scale for measuring polyp size when used during live colonoscopies. The investigators also wish to evaluate CAD-eye for detection and classification of polyp histology. It is hypothesized that CAD-eye and SCALE-EYE can function in real-time practice with high accuracy.
Status | Completed |
Enrollment | 348 |
Est. completion date | June 20, 2023 |
Est. primary completion date | June 20, 2023 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 45 Years to 80 Years |
Eligibility | Inclusion Criteria: - indication of undergoing a screening, surveillance, or diagnostic colonoscopy - Age 45-80 years - Signed informed consent Exclusion Criteria: - Known inflammatory bowel disease (IBD) - Active Colitis - Poor general health, defined as an American Society of Anesthesiologists (ASA) physical status class >3 - Coagulopathy - Familial polyposis syndrome - Emergency colonoscopies - Poor bowel preparation score defined as the total Boston bowel preparation score <6 and the right-segment score <2. For per-polyp analysis: 1. For optical diagnosis (CADx) we will exclude all polyps >5mm. We will also exclude sessile serrated polyps and traditional serrated adenomas from the analysis as CADx can only differentiate between adenomas and hyperplastic polyps. 2. For polyp size measurement (SCALE-EYE), we will exclude all polyps resected in several pieces (piecemeal resection), or specimens damaged (e.g., fractured) during the suction and retrieval process, submillimeter polyps too small for measurement after resection. Polyps after the 5th resected polyp in a single piece will be excluded to reduce the time associated with the procedure. 3. For polyp detection (CADe) we will not exclude any polyp from the analysis. |
Country | Name | City | State |
---|---|---|---|
Canada | Centre Hospitalier Universitaire de Montréal | Montréal | Quebec |
Lead Sponsor | Collaborator |
---|---|
Centre hospitalier de l'Université de Montréal (CHUM) |
Canada,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Evaluation of the Scale-Eye | to compare the relative accuracies of SCALE-EYE size measurement, visual size estimation or size estimation based on a standard polypectomy snare for colorectal polyps during real-time colonoscopies with measurement of viable specimens by a Vernier caliper as reference standard. Relative accuracy is defined as "1-[(ScaleEye measurement - gold standard measurement)/gold standard measurement] x100". Scale: 0-100. Higher score is a better outcome. | 30 days | |
Primary | Evaluation of CADe function | compare the adenoma detection rate between the CAD-eye-assisted colonoscopy and standard colonoscopy (i.e., detecting adenomas only by endoscopists) | 30 days | |
Primary | Evaluation of CADx function | evaluate the accuracy, sensitivity, specificity, positive and negative predictive value of CADx for classifying 1-5 mm polyp histology into neoplastic and non-neoplastic compared with the histopathology outcomes as the reference standard | 30 days | |
Secondary | Agreement and discrepancy between SCALE-EYE and other measurement | calculate the agreement and discrepancy between SCALE-EYE and other measurement methods | 30 days | |
Secondary | Video-based assessments | compare in video-based assessments with different endoscopists (expert level, staff GI, surgeons, trainees the relative size measurements accuracy of scale eye with visual and instrument based (snare and/or forceps) size measurement accuracy | 30 days | |
Secondary | CADe sensitivity in polyp detection | evaluate the sensitivity of the CAD-eye in combination with adjunct methods for real-time detecting colorectal polyps compared with standard colonoscopy | 30 days | |
Secondary | CADe function: proportion of polyps detected | to evaluate the proportion of polyps detected by the CAD-eye in combination with adjunct methods | 30 days | |
Secondary | Evaluation of CADx function | compare the accuracy, sensitivity, specificity, positive and negative predictive value of CADx for classifying 1-5 mm polyp histology to that of using human decision based on CADx suggestion | Through study completion, estimation: 3 months | |
Secondary | CADx proportion of polyp histology non-evaluable | calculate the proportion of 1-5 mm polyps, CADx can not suggest histology (in the intervention arm, please refer to the randomization section), while endoscopists can suggest histology with high confidence, or vice versa | 30 days | |
Secondary | CADx diagnostic uncertainty | evaluate diagnostic uncertainty of the current CADx module when predicting the pathology of colorectal polyps | 30 days | |
Secondary | 3D scanning assessment | evaluation of the relative accuracy of 3D scanned polyps compared to measurement of viable specimens by a Vernier caliper as reference standard. Relative accuracy is defined as "1-[(ScaleEye measurement - gold standard measurement)/gold standard measurement] x100". Scale: 0-100. Higher score is a better outcome. | 30 days | |
Secondary | Histologic size assessment | evaluation of the relative accuracy of histologic size measurement compared to measurement of viable specimens by a Vernier caliper as reference standard. Relative accuracy is defined as "1-[(ScaleEye measurement - gold standard measurement)/gold standard measurement] x100". Scale: 0-100. Higher score is a better outcome. | 30 days |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04192565 -
A Prospective Investigation of the ColubrisMX ELS System
|
N/A | |
Completed |
NCT04516785 -
Reducing Colonoscopies in Patients Without Significant Bowel Disease
|
||
Recruiting |
NCT05381792 -
Serial Gut Microbiome and Bacterial Gene Markers Changes After Endoscopic Resection of Colorectal Advanced Neoplasia
|
||
Withdrawn |
NCT05606081 -
Predicting Risk for Post-polypectomy Colorectal Cancer
|
N/A | |
Recruiting |
NCT05576506 -
Application of Hyperspectral Imaging Analysis Technology in the Diagnosis of Colorectal Cancer Based on Colonoscopic Biopsy
|
||
Active, not recruiting |
NCT03796884 -
Linaclotide in Treating Patients With Stages 0-3 Colorectal Cancer
|
Phase 2 | |
Completed |
NCT05508503 -
A Study on a Blood-based Dual-target Test for CRC Detection
|
||
Recruiting |
NCT02935049 -
Evaluation of the Resection of Adenoma and Colic Adenocarcinoma by EMR Piecemeal or EMR/ESD Hybrid Technique
|
N/A | |
Completed |
NCT05477836 -
Feasibility and Safety of MiWEndo-assisted Colonoscopy
|
N/A | |
Active, not recruiting |
NCT05754229 -
Accuracy of Real Time Characterization in Artificial Intelligence-assisted Colonoscopy
|
N/A | |
Active, not recruiting |
NCT05740137 -
Adenoma Detection Rate in Artificial Intelligence-assisted Colonoscopy
|
N/A | |
Completed |
NCT03234725 -
Analysis of New Endoscopic Features and Variable Stiffness in Colonoscopy: Prospective Randomised Trial
|
||
Completed |
NCT05913453 -
Technical Failure During Colorectal Endoscopic Full Thickness Resection (EFTR): The "Through Thick and Thin" Study
|
||
Recruiting |
NCT05261932 -
Research on Endoscopic Precision Biopsy.
|
||
Completed |
NCT02521727 -
To Investigate Risk of Colorectal Neoplasms in First-degree Relatives of Patients With Non-advanced Adenomas
|
||
Completed |
NCT02226185 -
Study of Berberine Hydrochloride in Prevention of Colorectal Adenomas Recurrence
|
Phase 2/Phase 3 | |
Completed |
NCT00298545 -
Effect of Vitamin D and Calcium on Genes in the Colon
|
Phase 1 | |
Completed |
NCT03268655 -
Ginger and Gut Microbiome (GINGER)
|
N/A | |
Active, not recruiting |
NCT04952129 -
Optimal Selenium for Bowel Polyps (OSCAR)
|
Phase 1 | |
Recruiting |
NCT04444908 -
Development and Validation of an Artificial Intelligence-assisted Strategy Selection System for Colonoscopy Cleaning
|