Clinical Trials Logo

Clinical Trial Summary

The goal of this clinical trial is to compare the detected adenoma per colonoscopy (APC) in participants undergoing screening, surveillance, and positive fecal immunochemical test (FIT) or guaiac fecal occult blood test (gFOBT). There will be two arms in this study: WE water control and water plus artificial intelligence (AI). The main question it aims to answer is whether the addition of AI into water exchange (WE) colonoscopy increases APC than WE alone. The control method will use water instead of air inserted into the colon. The study method will use a commercially available AI system plus water during the procedure. Researchers will compare APCs to see if the addition of AI increases detection of adenomas during WE colonoscopy.


Clinical Trial Description

This will be a multi-site, multi-national, unblinded investigators, prospective Random Control Trial (RCT). Randomization (1:1 to WE alone and WE-AI) will be based on computer generated random numbers placed inside opaque sealed envelopes. The envelope (in pre-arranged order) will be opened to reveal the code when the colonoscopist is ready to insert the endoscope to begin the examination. This will be a comparison of two different methods with two arms (WE, WE-AI) to see which one is better at detecting adenomas. Patient recruitment will be conducted at three hospitals in Italy and Taiwan: Digestive Endoscopy Unit, CTO Hospital, Iglesias, Italy; Digestive Endoscopy and Gastroenterology Unit, Manzoni Hospital, Lecco, Italy; Evergreen General Hospital, Taoyuan, Taiwan. The Sepulveda Ambulatory Care Center, VAGLAHS, UCLA in the USA will be a non-recruiting participating site. The study period is expected to be 3 years (from November 2023 to October 2026). Patients aged 45-75 y/o at average risk of colorectal cancer who are willing to participate will sign an informed consent before starting the colonoscopy procedure. Separate parallel randomization will be set up at each site, stratified by investigator and type of colonoscopy (primary screening, surveillance, or positive FIT or gFOBT). Mode of sedation will include unsedated, on demand sedation, conscious sedation or full sedation with propofol. Randomization will be carried out by computer-generated sequences using a block design (four participants per block). Control Method: One arm of the study will include sedated/unsedated colonoscopy with water (WE) as the control method. Residual air in the colon will be removed and water will be infused to guide insertion through an airless lumen. Infused water will be removed by suction, along with residual fecal debris, predominantly during insertion. Study method: The other arm entail the addition of a commercially available AI system (GI Genius, Medtronic; CAD-EYE, Fujifilm; Endo-AID, Olympus) to the high-definition colonoscopy system. This arm includes sedated/unsedated colonoscopy with AI detection device plus water (WE). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06173258
Study type Interventional
Source Evergreen General Hospital, Taiwan
Contact Chi-Liang Cheng
Phone 0919768058
Email chiliang.cheng@gmail.com
Status Recruiting
Phase N/A
Start date December 18, 2023
Completion date October 31, 2026

See also
  Status Clinical Trial Phase
Completed NCT04101097 - Training and Validation of Models of Factors to Predict Inadequate Bowel Preparation Colonoscopy
Completed NCT03247595 - Testing How Well Magnesium Citrate Capsules Work as Preparation for a Colonoscopy N/A
Completed NCT04214301 - An Open-Label Preference Evaluation of BLI800 Phase 4
Withdrawn NCT05754255 - Comparison of High-flow Oxygen With or Without Nasal Positive Airway Pressure (PAP) During Propofol Sedation for Colonoscopy in an Ambulatory Surgical Center N/A
Recruiting NCT02484105 - Comforting Conversation During Colonoscopy: A Trial on Patient Satisfaction Phase 4
Active, not recruiting NCT02264249 - Residual Gastric Volume in Same Day Versus Split Dose and Evening Before Bowel Preparation N/A
Completed NCT01964417 - The Comparative Study Between Bowel Preparation Method Phase 3
Terminated NCT01978509 - The Affect of Low-Volume Bowel Preparation for Hospitalized Patients Colonoscopies N/A
Recruiting NCT01685970 - Comparison of Same-day 2 Sachets Picosulfate Versus High Volume PEG for Afternoon Colonoscopy Phase 3
Completed NCT01518790 - Short Course, Single-dose PEG 3350 for Colonoscopy Prep in Children N/A
Recruiting NCT00748293 - Achievement of Better Examinee Compliance on Colon Cleansing Using Commercialized Low-Residue Diet N/A
Completed NCT00779649 - MoviPrep® Versus HalfLytely®, Low-VolUme PEG Solutions for Colon Cleansing: An InvesTigator-blindEd, Randomized, Trial Phase 4
Completed NCT00671177 - Clinical Evaluation of Water Immersion Colonoscopy Insertion Technique N/A
Completed NCT00380497 - Pico-Salax Versus Poly-Ethylene Glycol for Bowel Cleanout Before Colonoscopy in Children Phase 4
Recruiting NCT00160823 - Impact of a Self-Administered Information Leaflet on Adequacy of Colonic Cleansing for in-Hospital Patients Phase 3
Completed NCT00314418 - Patient Position and Impact on Colonoscopy Time N/A
Completed NCT00390598 - PEG Solution (Laxabon®) 4L Versus Senna Glycoside (Pursennid® Ex-Lax) 36mg and PEG Solution (Laxabon®) 2L for Large Bowel Cleansing Prior to Colonoscopy Phase 2/Phase 3
Completed NCT00427089 - Comparison of 2L NRL994 With NaP Preparation in Colon Cleansing Prior to Colonoscopies for Colon Tumor Screening Phase 3
Completed NCT00209573 - A Study of AQUAVAN® Injection Versus Midazolam HCl for Sedation in Patients Undergoing Elective Colonoscopy Phase 3
Completed NCT05823350 - The Effect of Abdominal Massage on Pain and Distention After Colonoscopy N/A