View clinical trials related to Cholecystitis.
Filter by:The Senhanceâ„¢ surgical robotic system, previously known as Telelap Alf-X (TransEnterix, Morrisville, NC, USA) has recently become available in the UK. It aims to provide the robotic benefits of greater accuracy, dexterity and control with similar operational costs to traditional laparoscopy. Patients randomly received either a standard laparoscopic cholecystectomy or the Senhance assisted cholecystectomy based on scheduled surgery date. A prospectively maintained database of the first 20 patients undergoing cholecystectomy with the Senhance Surgical System was retrospectively interrogated and compared to a concurrently treated group of 20 laparoscopically treated patients during the same timeframe.
This VA QUERI Partnered Evaluation Initiative will evaluate the impact of an immersive Point-of-care Ultrasound (POCUS) Training Course on provider skill acquisition and retention; the frequency of POCUS use by trained providers; and the barriers/facilitators to POCUS in the VHA. Data sources include pre- and post-course assessment tools, medical coding data, and course evaluations. Providers that participate in the POCUS Training Course will be compared to control providers from wait-listed facilities. Additionally, participating facilities vs. wait-listed facilities for the POCUS Training Course will be compared. Findings from this project will guide ongoing efforts of the investigators' operating partners, VA Specialty Care Centers of Innovation (SCCI) and the VA Simulation Learning and Research Network (SimLEARN), to develop a national POCUS training program and facilitate implementation of POCUS use system-wide in the VA healthcare system.
This study examines complications, mortality rates, cost-effectiveness and safety of early laparoscopic cholecystectomy (ELC) versus delayed laparoscopic cholecystectomy (DLC). Group L (n:88) patients treated surgically with laparoscopic cholecystectomy immediately or Group D (n:88) patients first treated medically and than treated surgically with delayed (4-8 weeks later) laparoscopic cholecystectomy.
Comparing the use of surgical robotics during a Cholecystectomy, comparing different platforms and approaches (multi port verses single port).
This study is intended to evaluate the efficacy and safety of glycopyrrolate as an antisialagogue prior to intubation with the rigid-videostylet(Optiscope®) in the general anesthesia settings. Upper airway secretions limit the use of the videostylet during during endotracheal intubation. Therefore, in this study, patients will be allocated to either of the two groups according to the administration of glycopyrrolate and the effect of glycopyrrolate in reducing oral secretions will be assessed by the observer while intubating with the rigid-videostylet. The efficacy of the antisialagogic effect on the view during endotracheal intubation will be evaluated.
The present study aims at analyzing whether ultrasonic tissue coagulation dissection technique offers a smoother peri- and postoperative course and reduces the risk for conversion from laparoscopic to open surgery in acute cholecystectomy patients as compared to electrocautery in case of acute cholecystitis The study is performed as a double-blinded study on patients undergoing laparoscopic surgery for acute cholecystitis. Patients included in the study are randomized to surgery with either the traditional electrocautery based technique or ultrasonic scalpel based dissection.
To evaluate clinical efficacy and safety of a novel lumen-apposing FCSEMS for EUS-guided transenteric drainage of PFC or of biliary tree including GB
The aim of this study is to compare early postoperative outcomes of unselected consecutive patients underwent laparoscopic cholecystectomy (LC) under spinal versus general anesthesia.
Introduction: Three-dimensional key-hole surgery ('laparoscopic') systems are proven to reduce the time required to complete tasks in laboratory settings. This benefit derives from the addition of binocular depth perception cues when compared to two-dimensional (2D) systems. This year a '4K' laparoscopic system has become commercially available, so-named as it provides a high resolution 2D image with four times the number of pixels of 2D full high definition. The improved visualisation is likely to provide additional non-binocular depth cues. It is currently unclear to what degree improving the resolution of 2D systems can compensate for binocular depth cues. Aim: To determine whether the binocular vision provided by 3D laparoscopic systems provides benefits during laparoscopic cholecystectomy when compared to the monocular vision provided by high-resolution 4K systems. Methods: A randomised controlled trial of 3D HD versus 4K laparoscopic systems will be performed, comparing the time to complete laparoscopic cholecystectomy, and error scores. Impact: This study is a unique, first-of-its-kind investigation into two new surgical technologies, and is the first study to involve a 4K system. The uptake of three-dimensional systems has been curbed by financial cost and the limitations of early 3D technologies. This study aims to determine which system may be the safest, quickest and most cost- effective, in order to guide future investment and technological development towards either 3D or 2D systems. In addition, these systems may also aid in the learning curve of trainee surgeons.
A semi-rigid cervical collar is recommended for immobilization of the cervical spine in patients with cervical spine injury. It has been suggested that a reduction in mouth opening is the major contributing factor to the deterioration in the glottic view obtained. Fiberoptic intubation is among the most versatile techniques for managing both the anticipated and the unanticipated difficult airway. Recently, combination of fiberoptic bronchoscope with videolaryngoscope has been suggested to permit visual control of the passage of the tube over the fibrescope into the laryngeal inlet. The aim of this study is to compare the intubation time and ease of intubation between fiberoptic bronchoscope alone and bronchoscope with pentax airwayscope.