Cardiac Output Clinical Trial
Official title:
The Application of Total-body 13N-NH3 PET/CT to Study the Blood Perfusion System in the Whole Body
The aim of our study is to analyze and quantitate whole-body blood perfusion by total-body 13N-NH3 PET/CT(uEXPLORER), and evaluate the influence to other organs caused by the decreased cardiac function.
Participants are invited to participate in a research that seeks to understand the dynamic blood perfusion in human body. The investigators expect to have twenty-five participants in this study at Renji Hospital, Shanghai. About sixteen of the participants will be patients who have been diagnosed with decreased cardiac function, nine participants will be healthy individuals with no known vascular disease. These healthy subjects will allow researchers to compare blood perfusion difference with those of persons with decreased cardiac function. All the participants will undergo the same procedure. If participants agree to participate in this study, researchers will first interview participants and review the past medical record in order to document the medical history. When the screening procedures confirm that participants are eligible to participate in the study, participants will receive one dose of the non-therapeutic administration of a radioactive tracer called N-13 ammonia(13NH3) , then undergo one total body 13NH3 PET/CT Scan (uEXPLORER) to determine the blood flow value of the brain, kidney and other organs. The total body 13NH3 PET/CT Scan will allow investigators to observe and analyze the real-time blood flow differences between patients with between healthy controls and decreased cardiac function. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04604886 -
The Consistency of Cardiac Output Measured by Pulmonary Artery Catheter and LiDCO in Cardiac Surgical Patients
|
N/A | |
Completed |
NCT04044157 -
Cardiac Output in Children During Anesthesia
|
||
Not yet recruiting |
NCT01678066 -
A Prospective Study to Bilaterally Compare a Non-Invasive Cardiac Output Monitor
|
N/A | |
Completed |
NCT01001533 -
Assess the Ability of Electrical Cardiometry to Trend Hemodynamic Variables During Dexmedetomidine Sedation
|
N/A | |
Recruiting |
NCT04926220 -
Dynamic Estimation of Cardiac Output in the Operating Room
|
||
Not yet recruiting |
NCT06007196 -
Evaluation of Non-invasive Continuous Hemodynamic Measurement From Task Force CORE
|
||
Recruiting |
NCT05648279 -
Personalized Hemodynamic Management in High-risk Major Abdominal Surgery
|
N/A | |
Recruiting |
NCT06090396 -
Non-invasive Cardiac Index in Children
|
||
Completed |
NCT05508711 -
Comparability of Transesophageal Echocardiography and FloTrac/Vigileo System Three Different Positions
|
||
Completed |
NCT02438228 -
Cardiac Output by Nine Different Pulse Contour Algorithms
|
N/A | |
Withdrawn |
NCT00783679 -
The Feasibility and Accuracy of Exhaled CO2 to Measure Cardiac Output in Ventilated Patients Without Tracheal Intubation
|
N/A | |
Completed |
NCT00996190 -
Best Regimen for Phenylephrine Administration During Cesarean Section
|
Phase 4 | |
Active, not recruiting |
NCT04465201 -
The Smart Pump Study
|
N/A | |
Completed |
NCT05779683 -
Caretaker in the Cardiovascular Intensive Care Unit (CVICU)
|
||
Completed |
NCT04112719 -
Assessing Effects of Lateral Tilt on Cardiac Output Using a Non-invasive Technique
|
||
Recruiting |
NCT02156856 -
Stroke Volume Analysis During Aortic Valve Replacement Trial
|
N/A | |
Recruiting |
NCT01781260 -
Effect of Prone Position on Liver Blood Flow and Function
|
N/A | |
Terminated |
NCT00920569 -
Recirculation, Oxygenator Blood Volume and Cardiac Output Measurements During Extracorporeal Membrane Oxygenation
|
N/A | |
Recruiting |
NCT06114147 -
Cardiac Flow Measurements in Pregnant Women by Non Invasive Techniques
|
N/A | |
Completed |
NCT05365113 -
Comparison of Hemodynamic Effects of Two Modalities of Alveolar Recruitment Maneuvers in Major Abdominal Surgery Patients
|
N/A |