Cardiac Output Clinical Trial
Official title:
Increased FIO2 Influences SvO2 Interpretation and Accuracy of Fick-based Cardiac Output Assessment in Cardiac Surgery Patients
In this study, the investigators sought to clarify the influence of FIO2 levels on the variables in the Fick equation and then assessed the influence of each variable on the accuracy of Fick-CO measurements in patients undergoing cardiac surgery.
Patients who are aged ≥20 years, are undergoing planned elective cardiac surgery, and
provided signed informed consent are included in the present study. Any patients with an
intra-cardiac shunt are excluded.
The patients are randomly assigned to 2 groups: FIO2 <0.7 or FIO2 >0.85. And during the
surgery, the oximeter values are kept ≥98%. Intra-operatively, FIO2, PaO2, SaO2, SvO2, PvO2,
Hb, blood pH values, body temperature and TD-CO are recorded.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04604886 -
The Consistency of Cardiac Output Measured by Pulmonary Artery Catheter and LiDCO in Cardiac Surgical Patients
|
N/A | |
Completed |
NCT04044157 -
Cardiac Output in Children During Anesthesia
|
||
Not yet recruiting |
NCT01678066 -
A Prospective Study to Bilaterally Compare a Non-Invasive Cardiac Output Monitor
|
N/A | |
Completed |
NCT01001533 -
Assess the Ability of Electrical Cardiometry to Trend Hemodynamic Variables During Dexmedetomidine Sedation
|
N/A | |
Recruiting |
NCT04926220 -
Dynamic Estimation of Cardiac Output in the Operating Room
|
||
Not yet recruiting |
NCT06007196 -
Evaluation of Non-invasive Continuous Hemodynamic Measurement From Task Force CORE
|
||
Recruiting |
NCT05648279 -
Personalized Hemodynamic Management in High-risk Major Abdominal Surgery
|
N/A | |
Recruiting |
NCT06090396 -
Non-invasive Cardiac Index in Children
|
||
Completed |
NCT05508711 -
Comparability of Transesophageal Echocardiography and FloTrac/Vigileo System Three Different Positions
|
||
Completed |
NCT02438228 -
Cardiac Output by Nine Different Pulse Contour Algorithms
|
N/A | |
Withdrawn |
NCT00783679 -
The Feasibility and Accuracy of Exhaled CO2 to Measure Cardiac Output in Ventilated Patients Without Tracheal Intubation
|
N/A | |
Completed |
NCT00996190 -
Best Regimen for Phenylephrine Administration During Cesarean Section
|
Phase 4 | |
Active, not recruiting |
NCT04465201 -
The Smart Pump Study
|
N/A | |
Completed |
NCT05779683 -
Caretaker in the Cardiovascular Intensive Care Unit (CVICU)
|
||
Completed |
NCT04112719 -
Assessing Effects of Lateral Tilt on Cardiac Output Using a Non-invasive Technique
|
||
Recruiting |
NCT02156856 -
Stroke Volume Analysis During Aortic Valve Replacement Trial
|
N/A | |
Recruiting |
NCT01781260 -
Effect of Prone Position on Liver Blood Flow and Function
|
N/A | |
Terminated |
NCT00920569 -
Recirculation, Oxygenator Blood Volume and Cardiac Output Measurements During Extracorporeal Membrane Oxygenation
|
N/A | |
Recruiting |
NCT06114147 -
Cardiac Flow Measurements in Pregnant Women by Non Invasive Techniques
|
N/A | |
Completed |
NCT05365113 -
Comparison of Hemodynamic Effects of Two Modalities of Alveolar Recruitment Maneuvers in Major Abdominal Surgery Patients
|
N/A |