The majority of newborns transition successfully from intrauterine to extrauterine life without any assistance. Less than 1% of all newborns will require extensive neonatal resuscitation involving chest compressions (CC) and medications at birth 1. Chest compressions are indicated for those newborns whose heart rate remains less than 60 beats per minute despite adequate ventilation 1. The American Heart Association (AHA) identifies two different methods of delivering chest compressions; a) the two-thumb (TT) method and b) the two-finger (TF) method. The two-thumb method is favoured by the AHA as it results in higher blood pressure and coronary perfusion pressures and can also be delivered from the head of the bed during umbilical catheter insertion 1.

The quality of CC plays a vital role in delivering effective cardiopulmonary resuscitation (CPR). Solevag et al. report that high-quality CC requires (A) optimal compression:ventilation (C:V) ratio, (B) adequate CC rate, (C) depth of CC as well as (D) full recoil between compressions 2. The American Heart Association (AHA) recommend delivering chest compressions on the lower third of the sternum to a depth of one third the anterior-posterior (AP) chest diameter. The recommended C:V ratio is 3:1 (90 compressions and 30 breaths per minute) 1.

A number of studies have highlighted the effects of rescuer fatigue on quality of chest compressions. One study reported adverse effects on CC quality when performed without interruption over a 3 minute period 6. It has therefore been recommended to rotate rescuers every 2-3 minutes in order to avoid rescuer fatigue and to ensure high quality CC6-7. As well as duration of CC, other factors can contribute to greater levels of rescuer fatigue. A number of studies have looked at the effect of different CC to ventilation methods on rescuer fatigue. Bodingh et al investigated this during simulated infant CPR. They reported greater levels of rescuer fatigue during simulated CPR in CCaV (continuous CC with asynchronous ventilation) at 120 CC per min compared to the recommended 3:1 C:V CPR 3. A similar study was performed by Li et al where rescuer fatigue was assessed during (i) 3:1 C:V ratio, (ii) CCaV at 90 CC per min and (iii) CCaV at 120 CC per min. However, unlike Bodingh et al, they found both 3:1 C:V and CCaV CPR to be equally fatiguing 4. Different CC techniques (TT vs TF method) can also cause varying levels of rescuer fatigue. In a recent study, Jiang et al compared the TT and TF chest compression techniques on infant mannequins and found that the TF method caused greater levels of rescuer fatigue compared with the TT method 5. We therefore set out to investigate whether different CC techniques cause different levels of rescuer fatigue during neonatal CPR. We hypothesize that performing TF method on neonatal mannequins will produce greater levels of rescuer fatigue. The results of this study would have significant implications in terms of choice of CC technique in new-born resuscitation.

The purpose of this study is to compare rescuer fatigue during simulated neonatal chest compressions using two different CC methods; the two-finger (TF) method vs two-thumb (TT) method. This will be performed on both preterm and term mannequins by neonatologists and level of fatigue will be assessed by measuring change in cardiac output during chest compressions.

Hypothesis: Performing CC using the two-finger (TF) method produces higher levels of rescuer fatigue compared with the two-thumb (TT) method during 5 minutes of simulated neonatal CPR.


Clinical Trial Description

Inclusion criteria

1. Neonatology NCHD's from CUMH

2. Participants must have completed Neonatal Resuscitation Programme (NRP)

3. Participants must be working as doctors in the area of neonatology Exclusion criteria

1. Any history of cardiac or respiratory disorder 2. Physicians who are post-call/sleep deprived

Intervention:

This will be a crossover trial. Each participant will be assigned to performing ether TT or TF chest compressions. The participant will each perform 5 minutes of simulated chest compressions either a term or preterm mannequin using 3:1 C:V CPR. Each participant will have NICOM leads attached to their body which will record HR and cardiac output. One week later the participant will cross over and perform the alternate CC technique. The trial will initially be performed on a term mannequin for the first 2 weeks before being repeated on a preterm mannequin.

Data Collection:

Recorded data will include: Age, gender, ethnicity, weight, height, BMI, HR and cardiac output. Participants will have an allocated study number, ensuring that the data collected will be anonymised. The list of study numbers and data will be stored in a secure password protected database in the Neonatal Unit. Only people involved in the study and other authorised persons will have access to this information.

Outcome Measures:

Primary Outcome Measure:

Percentage change in cardiac output after 5 minutes of simulated neonatal CPR using two different chest compression methods (2-finger method vs. 2-thumb method) on term and preterm mannequins.

Secondary Outcome Measure:

Perceived level of fatique. At the end of the study session each subject will complete a Likert scale-based questionnaire on subjective feeling of fatigue. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04111237
Study type Interventional
Source University College Cork
Contact
Status Completed
Phase N/A
Start date June 28, 2018
Completion date August 30, 2018

See also
  Status Clinical Trial Phase
Completed NCT05070819 - Atrial Natriuretic Peptide in Assessing Fluid Status N/A
Completed NCT06039397 - The Effect of Semi Fowler 30' Right Lateral on Cardiac Output in Acute Heart Failure N/A
Recruiting NCT05492968 - The Effect of Epinephrine, Norepinephrine and Phenylephrine on Intraoperative Hemodynamic Performance Phase 4
Completed NCT03444545 - Continous Cardiac Output - Non-Invasive Evaluation (CONNIE)
Recruiting NCT04064177 - Non-invasive Continuous Cardiac Output Monitoring in Preterm Infants Study
Withdrawn NCT03058653 - Use of a Mini-fluid Bolus to Identify Fluid Responsiveness N/A
Completed NCT04955184 - Comparing Cardiac Output Measurements Using a Wearable, Wireless, Non-invasive PPG-Based Device to a Swan Ganz Catheter
Recruiting NCT04755764 - Effect of Labetalol, Atenolol, and Nifedipine on Maternal Hemodynamics Measured by ICG in Early Pregnancy
Completed NCT01880684 - Validation of Capnography as a Predictor of Cardiac Output Change as Measured by FloTrac Phase 2
Completed NCT02312505 - Comparison of a New Semi-invasive Monitoring System With Transpulmonary Thermodilution in Cardiac Surgery Patients N/A
Enrolling by invitation NCT05441007 - The Effect of Hypercapnia on Physiological Parameters During Short-term Breathing N/A
Recruiting NCT04885699 - Validation of Capnodynamic Assessment of Mixed Venous Oxygen Saturation
Completed NCT00354211 - Using Minimally Invasive Cardiac Output Data vs. Standard Care for Patients Emergently Admitted to the Intensive Care Unit Who Are Hemodynamically Unstable Phase 4
Completed NCT04358822 - Hemodynamic Effects of Delayed Umbilical Cord Clamping in Full-term Newborns N/A
Completed NCT03046784 - Non-invasive Haemodynamic Monitoring in Pregnancy
Not yet recruiting NCT05646342 - PLR in a Good Helath After 24 Week of Preganancy
Completed NCT00583687 - Pulse Contour Analysis and Tissue Oxymetry in Changing Vascular Tone N/A
Completed NCT05428384 - Validation of CardioMEMS HF System Cardiac Output Algorithm IDE
Completed NCT03021525 - Individualized Perioperative Hemodynamic Goal-directed Therapy in Major Abdominal Surgery (iPEGASUS-trial) N/A
Recruiting NCT02778633 - Mean Systemic Filling Pressure and Heart Performance Predicting Fluid Responsiveness in Sepsis N/A