Clinical Trials Logo

Clinical Trial Summary

Electrical Impedance Tomography (EIT)is a technique based on the injection of small currents and voltage measurements using electrodes on the skin surface generating cross-sectional images representing impedance change in a slice of the thorax. It is a radiation free, non-invasive and portable lung imaging technique. Impedance changes in lung ventilation are investigated in mechanically ventilated patients who routinely undergo bronchoscopy in intensive care medicine. Bronchoscopy is performed to suction secretions as well as to analyze the secretions to recognize inflammations and diseases. It is an essential intervention which causes changes in ventilation which remain for 1-2 hours. It is not completely investigated why these changes in ventilation remain for so long time and how they are distributed regionally. Therefore the purpose of this study is to investigate the change in pulmonary regional ventilation in patients who routinely undergo bronchoscopy to possibly generate ideas how to optimize the ventilation after bronchoscopy to optimize the patient´s treatment.


Clinical Trial Description

In 20 mechanically ventilated patients who routinely undergo bronchoscopy Electrical Impedance Tomography (EIT) measurements whereby, evaluable data of 10 patients are needed, of about 1-2 minutes are performed directly before, directly after and 10, 30, and 60 minutes after bronchoscopy parallel to the following routine measurements: tidal volume, resistance, compliance, heart rate, blood pressure, SpO2 and blood gas values. Prior to the examination a rubber belt with 16 integrated electrocardiographic electrodes is placed around the thorax connected with an EIT- device. EIT data are generated by application of a small alternating current of 5mA and 50kHz and are stored and analyzed offline on a personal computer. The EIT provides a mapping of the distribution of the lung´s electrical impedance and exhibits a far temporal resolution of up to 40 tomograms per second. Because of electrical impedance of the pulmonal tissue is dependant to the air content, the air distribution within the lung over a certain period can be monitored. Analyzing the EIT- data it might be possible to explain the distribution in regional ventilation and how the ventilation could be optimized right after the bronchoscopy to optimize the patient´s treatment. ;


Study Design

Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Basic Science


Related Conditions & MeSH terms


NCT number NCT01294813
Study type Interventional
Source RWTH Aachen University
Contact Stefan Krueger, MD
Phone 0049 241 8080202
Email stkrueger@ukaachen.de
Status Recruiting
Phase N/A
Start date January 2011
Completion date April 2011

See also
  Status Clinical Trial Phase
Terminated NCT03581474 - Evaluation of BAL Procedure With Ambu aScope 3 Large in Patients in an ICU Setting N/A
Completed NCT03294213 - Prospective Non-interventional Evaluation of Intubation and Intensive Care Use of the New aScope™ 4 Broncho and aView
Completed NCT06116955 - The Application of Balanced Propofol Sedation in Fiberoptic Bronchoscopy
Withdrawn NCT03613792 - Remifentanil Plus Ketamine for Dynamic Flexible Bronchoscopy Phase 4
Completed NCT04016480 - HFNC During Bronchoscopy for Bronchoalveolar Lavage N/A
Recruiting NCT01100554 - Upper Airway Collapsibility Evaluation in Different Sedative Levels by Sleep Endoscopy N/A
Completed NCT00861835 - Trial of Rapid On-Site Evaluation of Transbronchial Needle Aspirate (TBNA) N/A
Completed NCT05154916 - The Effect of Virtual Reality Based Relaxation Program on Patients to be Performed Bronchoscopy N/A
Completed NCT03086408 - Transnasal Humidified Rapid-Insufflation Ventilatory Exchange (THRIVE) and Diagnostic Bronchoscopy N/A
Active, not recruiting NCT04884061 - Narrow Band Imaging Bronchoscopy During SARS-CoV2 Infection
Completed NCT05875662 - Pulmonary Ventilation After Fiberoptic Bronchoscopy Using EIT
Completed NCT00684684 - Safety and Feasibility Study of the Chartis System Phase 1
Completed NCT03521505 - Dexmedetomidine for Sedation of Endobronchial Ultrasound-guided Transbronchial Needle Aspiration Phase 4
Not yet recruiting NCT03856073 - The Training and Evaluate Effect on Clinical Airway Management for Novices. N/A
Not yet recruiting NCT03854760 - The Training and Evaluate Effect on Clinical Airway Management N/A
Recruiting NCT05912985 - Three Different Oxygenation Strategies in Bronchoscopy Procedures Under Sedation
Enrolling by invitation NCT05692362 - Measure Airway Compliance by Endobronchial Optical Coherence Tomography
Completed NCT03419546 - Clinical Validation Trial of a Single-use Bronchoscope (Ambu® aScope ™ 4)
Completed NCT03886454 - Incidence and Nature of Respiratory Impairment in Consecutive Patients Undergoing Bronchoscopy Under Conscious Sedation: A Pilot Study
Not yet recruiting NCT03983889 - Sedation Strategies for Diagnostic Bronchoscopy 2 N/A