Clinical Trials Logo

Clinical Trial Summary

Atrial fibrillation is the most common arrhythmia but can be treated by a catheter procedure where specialized wires (so-called catheters) are inserted in the left upper heart chamber. This requires crossing the wall between the right and left atrium with a long needle (a so-called transseptal puncture or TSP). This is typically done using x-ray guidance or echo to check if the needle is in the right position. The investigators developed a method to do the TSP without x-rays using a specialized needle that can be also shown as a little icon on the 3D electroanatomical mapping system (CARTO).3D mapping systems are routinely used to track the location of the catheters in cath labs worldwide, but the position of the needle was not tracked yet. The investigators seek to demonstrate that these procedures can be carried out safely, successfully and in a reproducible fashion without any radiation by taking advantage of "faking" the isolated tip of the needle as a catheter on the 3D mapping system. The results will be compared with historic procedures done by the same operator in the years 2012-2017.


Clinical Trial Description

The hypothesis is that patients who undergo one or more TSP(s) for atrial fibrillation or left atrial tachycardia can be studied without the use of fluoroscopy which should result in a low or ZERO overall radiation exposure for the entire ablation procedure. The investigators will assess the feasibility, safety and efficacy of this new approach.

The patient will be admitted in hospital as for a standard procedure and discharged the next day. Before admission, the patient undergoes a CMR/CT scan (routine in our centre). To avoid total radiation CMR would be preferred, if possible.

The technique of the TSP and the use of the RF needle is commonly used worldwide. The ability to visualize the needle tip on the 3D electroanatomical mapping system facilitates the procedure. The additional visualization by TOE helps to assure that the fossa ovalis has been correctly identified.

After the TSP, the ablation procedure itself will be carried out as conventionally performed using the catheter visualization on the 3D mapping system.

An ECG and an echocardiogram are performed before discharge (as standard care).

At 3 months the patient comes for the first visit and has an ECG, a Holter and symptom questionnaire.

At 6 months, the patient has second visit which includes an ECG, a symptom questionnaire, a Holter and an echocardiogram.

If recurrences of any arrhythmia occur, the patient can be scheduled for a second ablation procedure without any restrictions. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03750435
Study type Interventional
Source Royal Brompton & Harefield NHS Foundation Trust
Contact Sabine Ernst, MD
Phone 02073518612
Email s.ernst@rbht.nhs.uk
Status Recruiting
Phase N/A
Start date October 8, 2018
Completion date October 8, 2019

See also
  Status Clinical Trial Phase
Completed NCT00247351 - Prevention of Atrial Tachycardia After a Right Atriotomy N/A
Completed NCT04162249 - High Radiofrequency Power for Faster and Safer Pulmonary Veins Isolation - a Pilot Observational Study.
Recruiting NCT03209583 - ATrial Tachycardia PAcing Therapy in Congenital Heart
Recruiting NCT05883631 - RESOLVE-AF: Clinical Evaluation of the Ablacathâ„¢ Mapping Catheter and Ablamap® System Utilizing Electrographic Flow (EGF) Mapping to Resolve Extra-PV Sources of Atrial Fibrillation and Guide Ablation Therapy. N/A
Recruiting NCT05434650 - Abbott Atrial Fibrillation Post Approval Study
Completed NCT06335446 - Identification, Electro-mechanical Characterisation and Ablation of Driver Regions in Persistent Atrial Fibrillation
Recruiting NCT05014802 - Baseline Atrial Fibrosis Predicts Risk for Post-operative Atrial Fibrillation in Patients Undergoing Cardiac Surgery
Completed NCT05362656 - AutoMatic disPERsion Tagging Function Preliminary Evaluation N/A
Completed NCT05344456 - PVC Response ''Atrial Pace'' Inducing Atrial Tachycardias N/A
Not yet recruiting NCT05765565 - Comparison Between the Octaray and Pentaray Catheters in Patients Undergoing Ablation for Atrial Tachycardia. N/A
Recruiting NCT05521451 - Clinical Cohort Study - TRUST
Not yet recruiting NCT06327425 - MCG for Localization of Tachyarrhythmia's Origin N/A
Completed NCT03549806 - Stanford Cardiac Invasive Electrophysiology Novel Computer Experience
Completed NCT02451995 - Effectiveness of Ripple Mapping in Atrial Tachycardia Ablation N/A
Recruiting NCT03816033 - Cryotherapy Versus Radiofrequency Catheter Ablation Research Program N/A
Completed NCT05802576 - Study of Interference Between Oral Anticoagulants and Heparin During Ablation of Atrial Fibrillation (AF) or Left Atrial Tachycardia (GAD) by Catheter.
Completed NCT01108692 - Strategy of Early Detection and Active Management of Supraventricular Arrhythmia With Telecardiology (SETAM) N/A
Active, not recruiting NCT02374359 - Atrial Tachycardia as a Predictor of Atrial Fibrillation, Stroke and Mortality in Cryptogenic Stroke N/A
Completed NCT03151278 - Zero Fluoroscopic Ablation Versus Conventional Fluoroscopic Ablation for Right Atrial Arrhythmias N/A
Completed NCT03413150 - Modeling of Amiodarone Effect on Heart Rate Control in Critically Ill Patients With Atrial Tachyarrhythmias