Background: A Danish study raised the question of the usefulness of escalating energy protocols compared to fixed high-energy protocols. Maximal energies are usually the final choice of the physicians. Some authors showed that decreasing impedance by manual pressure application (MPA) had a positive impact on cardioversion outcome. This is likely due to the impedance decrease linked to MPA. Objective: This new clinical cardioversion study of atrial fibrillation (AF) patients aims to compare the efficacy and safety of a new high energy escalation strategy. The protocol combines high energy shocks at first shock, jumping to maximal defibrillator energy at second shock and finally complemented by MPA at third shock, if success is not reached using electric shocks only. Experimental design: Patients will be recruited at the Intensive Cardiology Care Unit, Cardiology Clinic, National Cardiology Hospital (NCH), Sofia, Bulgaria. All eligible patients will sign a written informed consent prior to the cardioversion and will receive the standard hospital procedures during cardioversion. AF patients will be alternatively randomized to cardioversion using one of the two defibrillators, following the strategy below: DEFIGARD HD-7 arm: 3 consecutive shocks with escalating selected energy: 150J, 200J, 200J. The third shock is combined with MPA LIFEPAK15 arm: 3 consecutive shocks with escalating selected energy: 150J, 360J, 360J. The third shock is combined with MPA The statistical power analysis will consider a superiority comparison between the cumulative energy actually delivered by both defibrillators. The secondary cardioversion efficacy outcome measures are: the cumulative success rate (measured at 1 minute post-shock), number of delivered shocks. Delivered energy will be measured during each shock with a dedicated pulse recording device (approved by the NCH Ethical Committee). Heart rhythm will be measured in continuously recorded peripheral ECG. The secondary cardioversion safety outcome measures are: markers for myocardial necrosis (high sensitive troponin I, CK-MB) evaluated on blood samples taken before and 8-12 hours after cardioversion; ST-segment changes (post-shock - pre-shock) measured in lead II; Complications after cardioversion measured during 2 hours follow-up period in the ICCU - the presence of apnea, arrhythmias, bradycardia and the need for respective therapy at the discretion of attending physician.


Clinical Trial Description

Background Commercially available defibrillators generate direct current (DC) shock with various waveforms using distinct technologies. These waveforms are suggested to have different efficacy and safety. Although the superiority of biphasic over monophasic waveforms is well established, the relative efficacy and safety of the available biphasic waveforms is not clear. Various BTE waveforms apply different potential gradients on the thorax that might produce various defibrillation effects. Apart from efficacy, the most important aspect is the patient safety, considering that larger potential gradients in the myocardium lasting longer could potentially induce an electroporation and then a fibrillation. A frequently observed effect of electroporation are the post-shock ST-segment deviations in the surface ECG, representing the potential difference between the normal tissue and sustained depolarized critical mass of myocardium closest to the associated origin of the electrical current. Although ST-segment changes are an easily ignored phenomenon, occurring acutely and resolving during the first few minutes post-shock, their presence in a short-term basis can identify electroporation by dangerously high potential gradients, while the sustained ST-changes in a long-term basis can identify cases with myocardial injury. The most reliable marker of shock-induced myocardial injuries is the high sensitive cardiac Troponin I (hsTnI). In a previous study Trendafilova et al. were compared fixed-high energy protocols (200J-200J-200J) delivered by two different defibrillation waveforms: Pulsed (BTE-PE) and High-energy BTE (BTE-HE). This study concluded on non-inferiority between devices. Cumulative energy, efficiency of the waveforms and safety (measured by High-sensitive Troponin) were not reaching significant difference for both waveforms. Delivered energy of the first efficient shock was significantly lower for BTE-PE and although BTE-PE delivered almost 28J lower energy after the whole procedure, significance could not be reached due to wide variance. In a Danish study Schmidt et al. compared two cardioversion protocols - one is fixed-high energy (360J-360J-360J), the other is low energy escalating (125J-150J-200J). The overall efficacy of fixed-energy protocol was better than escalating. Safety is non significantly different. Schmidt et al. raised the question of the usefulness of escalating energy protocols compared to fixed high-energy protocols. There is an ethical consideration to apply maximal energy shocks to all patients without considering patient individuality. Ramirez et al. remind that failed shocks might depend on other factors like transthoracic impedance. Lavignasse et al. found that cumulative energy setting differs with patient characteristics, having significant association with: AF duration, gender, BSA, LV TDD, valvular disease and chronic respiratory disease. Indeed, some authors (Voskoboinik et al. and Ramirez et al.) showed that decreasing impedance by manual pressure application (MPA) had a positive impact on cardioversion outcome. On most defibrillators, increasing the energy level is leading to an increase of the voltage delivered to the patient. This voltage increase implies a current increase in the thorax of the patient. In fact, applying a force on the defibrillation pads or increasing shock voltage by increasing the energy setting would lead to increase the current in the thorax, associated with expectations for higher shock efficiency. MPA is performed by pressing on the pads using a non-connected pair of paddles in order to assure isolation of the practitioner from the patient during the shock. Objective: This new clinical cardioversion study of atrial fibrillation (AF) patients aims to compare the efficacy and safety of a new high energy escalation strategy. The protocol combines reasonably high energy shocks complemented by MPA when necessary. Two biphasic defibrillators - a standard BTE-HE waveform (Lifepak 15, Physio Control) and a BTE-PE waveform (Defigard HD 7, Schiller Medical) with different maximal energy settings of 360J and 200J, respectively are compared. The proposed high energy escalation strategy is based on the hypothesis that most of the patients do not implicitly require the maximal levels of energy for cardioversion. Thus patients who could be easily cardioverted are removed from the pool that would need a more aggressive treatment. Methods: Study population All patients admitted for elective cardioversion of atrial fibrillation in ICCU- NCH will be potentially eligible for the study. Informed consent will be obtained from all eligible patients prior to cardioversion. Patients declining to participate in the study will receive treatment according to the hospital protocol. Cardiologists will check the eligibility of each patient following the detailed list of inclusion and exclusion criteria, based on the documented pre-treatment data. Additionally, eligibility will be verified through pre-cardioversion medical exams (blood test within 24 hours before cardioversion): routine blood chemistry, glucose, creatinine, eGFR, K, Na; CK-MB, high sensitive troponin I measurements on the day of cardioversion. Study design This will be a prospective randomized trial (alternating design) where eligible patients will be randomized to treatment with two different defibrillators. Following the order of patient admittance in ICCU-NCH, the attending cardiologist will assign the odd and even eligible patients to the defibrillators in arm 1 and arm 2, respectively. The cardiologist cannot control the order of patient admittance in ICCU-NCH. The alternative randomization design will equalize the number of subjects on each treatment. This study is not designed to control for sex, age, comorbidity, type of device used for cardioversion, cumulative energy delivered during shocks, number of shocks administered. Randomization is performed to limit these and any other confounding factors. Patient preparation Patients will be consulted prior to cardioversion (CV) in a quiet setting. Any questions will be answered by the attending cardiologist. Patients will be asked to manually sign their informed consent for study participation before further preparations and data collection. If the patient declines to participate, then he/she will receive treatment according to the hospital protocol without data documentation, as further defined in the study. Demographic data will be taken. Pre-treatment data will be read from the patient files: concomitant diseases; medications during the previous 7 days; Left atrium dimensions, left ventricle dimensions and volumes, ejection fraction by transthoracic echocardiography during index hospitalization; TEE will be performed for all patients before CV - presence of cardiac thrombus and spontaneous echo contrast will be checked; duration of index AF in days; European Heart Rhythm Association class score of symptoms from index AF; standard blood test will be documented. Appropriate standard anticoagulation with unfractionated heparin (UFH) or acenocumarol or direct oral anticoagulants (DOAC) is required before and after the CV. The anesthesia will be conducted by an anesthesiologist with slow intravenous injection of Propofol, adjusted individually to reach deep sedation (Cook' s scale points <7). Cardioversion protocol: The CV procedure is performed in ICCU by a cardiologist and anesthesiologist. Defibrillator pads are placed according to the user guides on the pads and respecting >40 cm distance between them. Standard self-adhesive defibrillation pads, recommended by specific defibrillator's manufacturer will be used. Defibrillator use: The time-interval interval between consecutive shocks is 1 min; The energy of consecutive shocks follows pre-defined protocol; The protocol stops at successful cardioversion (sinus rhythm at 1 min post-shock), otherwise at the last shock of the protocol. Data collection and Follow up: - Defibrillator pulse recorder: The shock waveforms delivered by the studied defibrillators is recorded in real-time during the shock by a dedicated measurement device (Defimpulse recorder DR2) connected in the patient circuit. This allows accurate measurement of the delivered energy, which is the primary measured outcome. Additionally, currents, voltages, patient impedances at each shock can be also measured. The device is fully automatic and expert assistance is not need during the CV intervention. The use of the measurement device (Defimpulse recorder DR2) has been approved by the NCH Ethical Committee. - Blood samples, standard ECG, blood pressure and heart rate at baseline. - Continuous ECG in 3 peripheral leads is recorded during the whole CV procedure. ST deviation is measured on the first cardiac complex after 10 s post-shock in standard manner (0.080 seconds after J point) in lead II. - Standard ECG is recorded in 5 min after CV; 24 h after CV; at discharge if the discharge day is different from 24 h after CV. - Heart rate and blood pressure are measured 3 times after CV during follow-up in ICCU - Follow-up period in ICCU (2 hours after CV): Potential complications after CV are recorded - Follow-up period in the Cardiology Clinic (24 hours after CV): blood samples to analyze CK-MB and troponin (8 to 12 h after CV); Clinical exam with heart rate and blood pressure; ECG; Any complications before discharge. Statistics: For arm1 (BTE PE waveform), the expected efficacy is 50% at the first shock (150J), 80% at the second shock (200J) and 85% at the third shock (200J combined with MPA). For arm2 (BTE HE waveform), the expected efficacy is 50% at the first shock (150J), 80% at the second shock (360J) and 85% at the third shock (360J combined with MPA). Taking into account that BTE PE waveform typically delivers 180J for energy setting of 200J, the estimated cumulative energy at the end of the CV procedure is 258J (+/-120J) and 366J (+/-240J) for arm1 and arm2, respectively. The statistical analysis is designed for a superiority comparison between the two defibrillation strategies in respect of their delivered cumulative energies hypothesizing similar cardioversion efficacy rate. It is estimated that a total of 94 patients (47 per arm) would allow to reach a statistical power of 80% in a superiority study design with one-sided type I error rate of 0.05. Continuous variables will be expressed as mean value ± standard deviation or median values (inter-quartile range) and compared with Students t-test or equivalent non-parametric test, respectively. Categorical variables are expressed as percentages and compared using the Chi-square or Fisher's exact test . P<0.05 is considered statistically significant for all comparisons. Ethics All patients will sign a written informed consent prior to the cardioversion and will receive the standard hospital procedures during cardioversion. Both defibrillators included in this study are approved for clinical use and both are used on a daily basis. Data anonymization policy will be respected. In order to ensure the medical confidentiality, no information about the patient will be entered in the defibrillators. An identification number will be given to each patient by the dedicated measurement device (Defimpulse recorder DR2). This number and the recording data are properties of the principal investigator. Approval from the NCH Ethical Committee concerning energy strategy and the use of the Defimpulse recorder during the cardioversion intervention has been obtained. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05316753
Study type Interventional
Source University National Heart Hospital
Contact Elina G Trendafilova, MD, PhD
Phone +359888718847
Email elitrendafilova@abv.bg
Status Recruiting
Phase N/A
Start date January 20, 2022
Completion date June 30, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A