Atrial Fibrillation Clinical Trial
Official title:
High-power Short-duration Radiofrequency Application for Faster and Safer Pulmonary Vein Ablation Trial (POWER FAST III Trial)
Multicenter 1:1 randomized study. Two atrial fibrillation ablation strategies are compared: 1) conventional ablation using point-by-point radiofrequency applications with power 40 W guided by LSI > 6 or AI > 500 on the anterior aspect of pulmonary veins and power 25 W guided by LSI >5 or AI >350 on the posterior wall near the esophagus; 2) point-by-point RF applications with power set at 70 W and duration 9-10 s. The main objective of the trial is the incidence of esophageal lesions evaluated with systematic endoscopy and clinical efficacy evaluated with daily ECG transtelephonic transmissions during 1-year follow-up. Secondary objectives include total RF time and parameters of acute PV isolation efficacy (first-pass isolation, acute reconnections and dormant conduction).
Multicenter 1:1 randomized study: Hospital Universitario La Paz, Madrid; Hospital Clínico Universitario San Carlos, Madrid; Hospital Clínico y Provincial de Barcelona, Barcelona; Complejo Hospitalario de Navarra, Pamplona; Hospital Clínico Universitario de Valladolid; Hospital Clínico Universitario de Albacete; Hospital Clínico Universitario de Alicante; Hospital Universitario Virgen de las Nieves, Granada; Hospital La Fe, Valencia; Hospital Clínico de Valencia; Hospital Universitario Juan Ramón Jiménez, Huelva; Hospital de la Ribera, Alzira, Valencia. España. Spain. Two atrial fibrillation ablation strategies are compared: 1) conventional ablation using point-by-point radiofrequency applications with power 40 W guided by LSI > 6 or AI > 500 on the anterior aspect of pulmonary veins and power 25-40 W guided by LSI >5 or AI >350 on the posterior wall near the esophagus; 2) point-by-point RF applications with power set at 70 W and duration 9-10 s. The main objective of the trial is the incidence of esophageal lesions evaluated with systematic endoscopy and clinical efficacy evaluated with daily ECG transtelephonic transmissions during 1-year follow-up. Secondary objectives include total RF time and parameters of acute PV isolation efficacy (first-pass isolation, acute reconnections and dormant conduction). Subestudy: asymptomatic cerebral lesions detected by 1,5 T MRI <72 h after ablation. Not all centers participate in the subestydy. However, if the center participates, all patients in both ablation groups will be included in the subestudy. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
Completed |
NCT04571385 -
A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF)
|
Phase 2 | |
Terminated |
NCT04115735 -
His Bundle Recording From Subclavian Vein
|
||
Completed |
NCT05366803 -
Women's Health Initiative Silent Atrial Fibrillation Recording Study
|
N/A | |
Completed |
NCT02864758 -
Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
|
||
Recruiting |
NCT05442203 -
Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease
|
N/A | |
Completed |
NCT05599308 -
Evaluation of Blood Pressure Monitor With AFib Screening Feature
|
N/A | |
Completed |
NCT03790917 -
Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
|
||
Enrolling by invitation |
NCT05890274 -
Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO
|
N/A | |
Recruiting |
NCT05316870 -
Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation
|
N/A | |
Recruiting |
NCT05266144 -
Atrial Fibrillation Patients Treated With Catheter Ablation
|
||
Not yet recruiting |
NCT06023784 -
The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block
|
N/A | |
Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
Recruiting |
NCT04092985 -
Smart Watch iECG for the Detection of Cardiac Arrhythmias
|
||
Completed |
NCT04087122 -
Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures
|
N/A | |
Completed |
NCT06283654 -
Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
|
||
Recruiting |
NCT05416086 -
iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study
|
N/A | |
Completed |
NCT05067114 -
Solutions for Atrial Fibrillation Edvocacy (SAFE)
|
||
Completed |
NCT04546763 -
Study Watch AF Detection At Home
|
||
Completed |
NCT03761394 -
Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke
|
N/A |