Atrial Fibrillation Clinical Trial
Official title:
Esophageal Temperature Management During Cryo AF Ablation
The purpose of this pilot study is to determine if esophageal warming using the Attune Medical Esophageal Heat Transfer Device (EnsoETM) limits the frequency or severity of thermal injury during cryoballoon ablation of atrial fibrillation.
Catheter ablation of atrial fibrillation (AF) has become a common ablation procedure performed worldwide. The cornerstone of this procedure is pulmonary vein isolation (PVI). PVI can be achieved by multiple methods, the two most common being radiofrequency (RF) and cryoablation. Energy delivery may extend beyond the atrial myocardium and result in damage to adjacent structures, including the esophagus. Atrio-esophageal fistula (AEF) is a rare, but a well-recognized complication of percutaneous AF ablation. The occurrence rate of esophageal injury has varied depending on the reporting center, timing of endoscopy, and the ablation technique utilized. Esophageal ulceration is likely the initial injury that leads to AEF formation and is probably present within hours to days of the ablation procedure. The Attune Medical Esophageal Heat Transfer Device (EnsoETM) is a non-sterile, multi-lumen silicone tube placed in the esophagus for the purpose of cooling or warming a patient while simultaneously allowing gastric decompression and drainage. For this study, the EnsoETM tube will be used during cardiac ablation procedures for the intended indication of patient temperature management using approved settings/parameters as detailed in the product instructions for use document. EnsoETM is an FDA approved device. This prospective, randomized study will include 40 patients with symptomatic AF undergoing index PVI under general anesthesia at Northwestern Memorial Hospital. Patients will be randomized in a 1:1 fashion with 20 patients (Group A) randomized to undergo the ablation procedure with esophageal warming and the other 20 patients (Group B) will serve as the control group and will not have the EnsoETM device used. All patients will undergo esophagogastroduodenoscopy (EGD) 1-2 days following the ablation procedure to evaluate for esophageal injury. ;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
| Completed |
NCT04571385 -
A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF)
|
Phase 2 | |
| Terminated |
NCT04115735 -
His Bundle Recording From Subclavian Vein
|
||
| Completed |
NCT05366803 -
Women's Health Initiative Silent Atrial Fibrillation Recording Study
|
N/A | |
| Completed |
NCT02864758 -
Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
|
||
| Recruiting |
NCT05442203 -
Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease
|
N/A | |
| Completed |
NCT05599308 -
Evaluation of Blood Pressure Monitor With AFib Screening Feature
|
N/A | |
| Completed |
NCT03790917 -
Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
|
||
| Enrolling by invitation |
NCT05890274 -
Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO
|
N/A | |
| Recruiting |
NCT05266144 -
Atrial Fibrillation Patients Treated With Catheter Ablation
|
||
| Recruiting |
NCT05316870 -
Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation
|
N/A | |
| Not yet recruiting |
NCT06023784 -
The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block
|
N/A | |
| Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
| Recruiting |
NCT04092985 -
Smart Watch iECG for the Detection of Cardiac Arrhythmias
|
||
| Completed |
NCT04087122 -
Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures
|
N/A | |
| Completed |
NCT06283654 -
Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
|
||
| Recruiting |
NCT05416086 -
iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study
|
N/A | |
| Completed |
NCT05067114 -
Solutions for Atrial Fibrillation Edvocacy (SAFE)
|
||
| Completed |
NCT04546763 -
Study Watch AF Detection At Home
|
||
| Completed |
NCT03761394 -
Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke
|
N/A |