Atrial Fibrillation Clinical Trial
Official title:
Esophageal Deviation in Atrial Fibrillation Ablation
Catheter ablation with pulmonary vein (PV) isolation is a commonly performed strategy employed for the treatment of atrial fibrillation (AF). However, ablation in the posterior wall of the left atrium can cause thermal injury to the esophagus. Thermal injury is very common and occurs in up to 40% of AF ablations per some studies. When significant thermal injury to the esophagus occurs, two significant complications can arise: 1) the formation of an atrio-esophageal fistula, and 2) gastrointestinal dysmotility. While the occurrence of fistula is rare, it is a very important complication since it is often fatal. Currently luminal esophageal temperature monitoring is the most commonly employed modality to prevent such injury. However, there are limitations to its use, and atrio-esophageal fistulas continue to be a major problem in AF ablation even when using esophageal temperature monitoring. Esophageal deviation using either a Transesophageal echocardiogram (TEE) or Esophagogastroduodenoscopy (EGD) probe has been described in the literature, but the effectiveness and practicality of these techniques are suboptimal, and have therefore precluded their use in routine clinical practice. Recently, esophageal deviation using off-the-shelf equipment (a soft thoracic tube and endotracheal stylet) was tested in the randomized double-blind multicenter study "Deviating the Esophagus in Atrial Fibrillation Ablation (DEVIATE-AF)". In that study the standard practice (i.e., use of luminal esophageal temperature monitoring) was compared to esophageal deviation using off-the-shelf equipment. The results were very encouraging showing that esophageal deviation allowed for significant reductions in esophageal temperature and proportion of premature ablation terminations. Importantly, esophageal deviation allowed the isolation all PVs in the treatment group, which was not the case in the control group. One major limitation in the DEVIATE-AF trial was that off-the-shelf equipment tool was challenging to use. The aim of the Esophageal Deviation in Atrial Fibrillation Ablation study is to test the feasibility and safety of moving the esophagus using a specialized esophageal deviation tool (DV8, Manual Surgical Sciences, Minneapolis, MN).
n/a
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
| Terminated |
NCT04115735 -
His Bundle Recording From Subclavian Vein
|
||
| Completed |
NCT04571385 -
A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF)
|
Phase 2 | |
| Completed |
NCT05366803 -
Women's Health Initiative Silent Atrial Fibrillation Recording Study
|
N/A | |
| Completed |
NCT02864758 -
Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
|
||
| Recruiting |
NCT05442203 -
Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease
|
N/A | |
| Completed |
NCT05599308 -
Evaluation of Blood Pressure Monitor With AFib Screening Feature
|
N/A | |
| Completed |
NCT03790917 -
Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
|
||
| Enrolling by invitation |
NCT05890274 -
Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO
|
N/A | |
| Recruiting |
NCT05266144 -
Atrial Fibrillation Patients Treated With Catheter Ablation
|
||
| Recruiting |
NCT05316870 -
Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation
|
N/A | |
| Not yet recruiting |
NCT06023784 -
The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block
|
N/A | |
| Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
| Recruiting |
NCT04092985 -
Smart Watch iECG for the Detection of Cardiac Arrhythmias
|
||
| Completed |
NCT04087122 -
Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures
|
N/A | |
| Completed |
NCT06283654 -
Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
|
||
| Recruiting |
NCT05416086 -
iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study
|
N/A | |
| Completed |
NCT05067114 -
Solutions for Atrial Fibrillation Edvocacy (SAFE)
|
||
| Completed |
NCT04546763 -
Study Watch AF Detection At Home
|
||
| Completed |
NCT03761394 -
Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke
|
N/A |