Clinical Trials Logo

Clinical Trial Summary

Warfarin therapy is usually monitored using the international normalized ratio (INR), and prolonged INR means coagulation impairment that can leads elevating transfusion requirement after operation. This study was designed to assess the relationships with warfarin and TEG values related to transfusion amount, to set up blood transfusion strategy in patients on atrial fibrillation undergoing cardiac surgery.


Clinical Trial Description

This study was a retrospective evaluation of patients who have received cardiac surgery with Maze-operation from March 2008 to November 2013.

Patients who have atrial fibrillation undergoing cardiac surgery with Maze-operation were included.

The following exclusion criteria are applied:

1. Patients who have taken medicine related to coagulation (such as antiplatelets like aspirin and clopidogrel) except warfarin or bridged heparin

2. Patients whose laboratory values could not be confirmed by medical records review.

Patients were categorized by two groups.

1. W group: patients on atrial fibrillation who have taken warfarin for p.o medication.

2. C group: patients on atrial fibrillation who have not taken warfarin for p.o medication.

Using blood sample, authors examined as follows:

1. Preoperative (maximum 5days before operation) and postoperative (30min after ICU admission) coagulation values with haematologic values: PT/aPTT, INR, Hb, Hct, platelet levels.

2. ROTEM values at 30min after anaesthetic induction and 30min after ICU admission: Clotting time (CT), clot formation time (CFT), maximum clot firmness (MCF), maximum lysis (ML)

3. Intraoperative (during operation) and postoperative (during admission, an expected average of 5 weeks) total transfusion amount: RBC, FFP, PC, cryoprecipitate.

4. Post operative 24 hr bleeding amount in the chest tube drain bottle.

5. The duration (maximum 2 weeks) of warfarin discontinuation. (in W group)

Statistical analysis was performed using unpaired t-test and chi-square test to compare patients demographic data and other parameters. To determine the relationship of INR and ROTEM parameters with bleeding amount and transfusion amount, multiple linear regression model that accounted for all confounder variables was used. For each factor in the multiple regression model, variables with a p value of less than 0.10 were kept in the final model. The data was analyzed using the program Statistical Package for the Social Sciences ver. 18.0 (SPSS Inc, Chicago, USA). A value of p < 0.05 was considered statistically significant. ;


Study Design

Observational Model: Cohort, Time Perspective: Retrospective


Related Conditions & MeSH terms


NCT number NCT02191449
Study type Observational
Source Konkuk University Medical Center
Contact
Status Completed
Phase N/A
Start date June 2014
Completion date February 2015

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A