Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01448265
Other study ID # CRYO-MAP
Secondary ID
Status Completed
Phase Phase 4
First received September 30, 2011
Last updated July 24, 2013
Start date September 2011
Est. completion date July 2013

Study information

Verified date July 2013
Source Heidelberg University
Contact n/a
Is FDA regulated No
Health authority Germany: Ethics Commission
Study type Interventional

Clinical Trial Summary

Background: Atrial fibrillation (AF) is the most frequent sustained cardiac arrhythmia, impairs quality of life and increases stroke risk and mortality. Recent clinical experience with the Arctic Front™ cryoballoon ablation catheter system (Medtronic) suggests that it can be used to isolate the pulmonary veins (PVs) safely and effectively in patients with AF, thereby eliminating the recurrence of AF.

Hypothesis: Our hypotheses are (1) that visualization of real-time pulmonary vein conduction during cryoballoon ablation of atrial fibrillation using a novel spiral circumferential mapping catheter (Achieve™) is feasible and safe, and (2) that procedure and fluoroscopy times decrease with experience.

Objective: The purpose of this study is to assess safety, feasibility, and a learning curve associated with cryoballoon catheter ablation using a novel circular mapping catheter (Achieve™, Medtronic) inserted through the lumen of the cryoballoon in patients with symptomatic paroxysmal atrial fibrillation.

The primary goal is to evaluate successful pulmonary vein isolation using the Achieve™ mapping catheter. The reduction of procedure and fluoroscopy times during the first 40 patients treated with this approach will be analyzed to evaluate a potential learning curve upon introduction of the technique.


Description:

A total of 40 patients scheduled for a first ablation of paroxysmal AF will be included. All study subjects will undergo cryoablation using the 28 mm Arctic Front™ Cryoablation Catheter. A double transseptal approach will be followed in all study patients, allowing for use of regular guide wire and circular mapping catheter, respectively, if required.

Use of the 20 mm Achieve™ circular mapping catheter is preferred. The 15 mm AchieveTM catheter may be used at the physician's discretion. If stable balloon positions cannot be obtained, the Achieve™ catheter will be replaced by a regular guide wire and pulmonary vein isolation will be assessed by a circular mapping catheter (Lasso™; Biosense Webster) introduced through a second transseptal puncture. Cryoablations will be applied for 5 minutes each. Premature terminations will be allowed at the physician's discretion but should be avoided to allow for detection of late pulmonary vein isolation during cryoenergy application. Cryoballoon catheter manipulations (e.g., pull down maneuver) may be performed during energy application. During ablation of septal pulmonary veins, electrical phrenic nerve stimulation will be performed to exclude phrenic nerve palsy. If additional single point ablations are required to achieve electrical isolation of pulmonary veins, a linear cryocatheter (Freezor™ Max; Medtronic) will be used.


Recruitment information / eligibility

Status Completed
Enrollment 40
Est. completion date July 2013
Est. primary completion date July 2013
Accepts healthy volunteers No
Gender Both
Age group 18 Years to 75 Years
Eligibility Inclusion Criteria:

- Documented paroxysmal atrial fibrillation

- =18 and =75 years of age

- Failure of one or more antiarrhythmic drugs

- Referral for a pulmonary vein isolation catheter ablation procedure to treat atrial fibrillation

Exclusion Criteria:

- Previous ablation of atrial fibrillation

- Documented left atrial thrombus

- Irregular pulmonary vein anatomy according to transesophageal echocardiography

- Atrial fibrillation secondary to reversible cause

- Amiodarone therapy in the previous 6 months

- Cardiac surgery within the prior 6 months

- Myocardial infarction within the previous 2 months

- Ejection fraction < 40%

- NYHA class III or IV

- Moderate to severe valvular heart disease

- Previous valve replacement

- Pacemaker or implantable cardioverter defibrillator placement in the prior 3 months

- History of stroke or TIA within the previous 12 months

- Left atrial size = 50 mm

- Contraindication for anticoagulation medication

- Life expectancy of less than 12 months

- Pregnancy

Study Design

Endpoint Classification: Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


Intervention

Procedure:
Cryoballoon ablation.
Cryoballoon ablation using a novel circular mapping catheter.

Locations

Country Name City State
Germany Department of Cardiology, University of Heidelberg Heidelberg

Sponsors (2)

Lead Sponsor Collaborator
Heidelberg University Medtronic

Country where clinical trial is conducted

Germany, 

Outcome

Type Measure Description Time frame Safety issue
Primary Feasibility, defined as successful pulmonary vein isolation using the novel circular mapping catheter with the cryoballoon. Participants will be followed for the duration of the ablation procedure, an expected average of 1-3 hours. No
Secondary Time from beginning of the freeze to conduction blockade ("time to effect"). Participants will be followed for the duration of the ablation procedure, an expected average of 1-3 hours. No
Secondary Treatment-related adverse events. Participants will be followed for the duration of the ablation procedure, an expected average of 1-3 hours. Yes
Secondary Procedure time. Participants will be followed for the duration of the ablation procedure, an expected average of 1-3 hours. No
Secondary Overall fluoroscopy time and dose. Participants will be followed for the duration of the ablation procedure, an expected average of 1-3 hours. No
See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A