Clinical Trials Logo

Clinical Trial Summary

The purpose of this research is to simplify the standard recording system of the heart rhythm. The investigators desire to improve the ease of monitoring the cardiac rhythm for 24 hours. The investigators intent is to use a very small, innovative monitoring patch system that relieves the patient of wearing a cumbersome and uncomfortable recording system. This research trial will carry the title "The Simple ECG Monitoring" for Comparison of a Sternal ECG Recording System with a Standard ECG Recording System for Holter Monitoring. The data from the investigational device is for comparative purposes only. It will not be used by medical personnel for study subject treatment or diagnostic purposes.


Clinical Trial Description

Externally applied cardiac rhythm monitors are common tools used to diagnose symptoms that may or may not be related to cardiac rhythm abnormalities. Common problems that may lead to the use of cardiac rhythm monitors are syncope (loss of consciousness), near-syncope (near loss of consciousness), palpitations (the sensation of an abnormal heart beat), or monitoring of known cardiac rhythm problems like atrial fibrillation. The purpose of this research is to confirm the clinical value of a much easier-to-use cardiac rhythm monitoring system, hereafter referred to as the Investigational Monitoring System. Prior to discussing the investigational monitoring system, we will review standard electrocardiographic monitoring tools used to evaluate the heart's rhythm.

Excluding a routine 12 lead electrocardiogram that takes a snapshot view of the hearts electrical signal, the most common tool for monitoring the heart rhythm is a Holter monitor. A Holter monitor is also called an ambulatory cardiac monitor. A Holter monitor records every heartbeat for 24 hours. It requires wearing multiple electrodes and carrying a recording system that is usually worn on a belt or on a holster strap. Such systems are relatively bulky and difficult to conceal in public venues. Also, their electrodes often disconnect, especially during sleep when the patient is unaware of electrode detachments that can occur when turning or during exercise. Moreover, they can't be worn during showering. These shortcomings notwithstanding, standard Holters remain the standard of care. ;


Study Design

Observational Model: Cohort, Time Perspective: Prospective


Related Conditions & MeSH terms


NCT number NCT01382953
Study type Observational
Source Seattle Institute for Cardiac Research
Contact
Status Completed
Phase N/A
Start date August 2011
Completion date October 2011

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A