Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT00001946
Other study ID # 000028
Secondary ID 00-CC-0028
Status Completed
Phase Phase 1
First received January 18, 2000
Last updated March 3, 2008
Start date December 1999
Est. completion date September 2002

Study information

Verified date September 2002
Source National Institutes of Health Clinical Center (CC)
Contact n/a
Is FDA regulated No
Health authority United States: Federal Government
Study type Interventional

Clinical Trial Summary

This study will evaluate ways to improve magnetic resonance angiography (MRA) for diagnosing atherosclerosis (hardening and narrowing of the arteries).

MRA is a new method for looking at arteries and veins without standard angiography, which requires inserting a catheter into a blood vessel, injecting a contrast material, and obtaining X-ray images. Current MRA techniques, however, do not depict the lumen (cavity) of small vessels well enough to accurately determine the extent of their narrowing. This study will test image processing methods with the eventual goal of improving MRA accuracy to the point that it can replace X-ray catheter angiography for diagnosing atherosclerotic disease.

Patients with atherosclerosis who have had conventional angiography at Suburban Hospital in Bethesda, MD, may be considered for this study. They will be screened with a brief history and physical examination, and those enrolled will have a MRA scan within 72 hours of their conventional angiogram. For this procedure, a catheter is placed in a vein in the patient's arm and the patient lies on a table that slides into a magnetic resonance imaging (MRI) scanner-a large donut-shaped machine with a magnetic field. Surface coils-flexible, padded antennae used to improve the quality of the pictures-are wrapped around the patient's legs. At times during the scan, the patient is asked to hold his or her breath for several seconds, and a contrast material called gadolinium is injected through the catheter in the vein. This substance enhances the images of blood flow in the vessels. The procedure generally takes about an hour and a half, although the actual imaging takes only a small part of that time.


Description:

Contrast Enhanced Magnetic Resonance Angiography (MRA) is a developing technology for the non-invasive evaluation of arterial and venous structures which does not require x-ray based catheter angiography. While dramatic progress in MRA has recently been made, there are still substantial limitations in the accuracy of MRA in grading stenoses and detecting small accessory vessels. The purpose of this study is to recruit patients with documented atherosclerotic disease as confirmed on catheter angiography performed at Suburban Hospital for evaluation with state-of-the-art MRA on MRI units, also at Suburban Hospital. We intend to test new surface coils, new pulse sequence designs, and advanced image processing algorithms in order to improve MRA accuracy to the point that a large-scale study of MRA vs. conventional angiography is possible. The goal of this pilot study is to improve MRA to the point that it can reliably replace diagnostic x-ray catheter angiography in the evaluation of patients with atherosclerotic disease.


Recruitment information / eligibility

Status Completed
Enrollment 40
Est. completion date September 2002
Est. primary completion date
Accepts healthy volunteers No
Gender Both
Age group N/A and older
Eligibility Patient must be willing to participate in the study.

Patient must have documented atherosclerotic disease of an extracranial vessel by angiography performed within 72 hours of the MRA.

Patient must be referred by a physician who is caring for the patient and to whom the results will be provided.

Patient must be clinically stable and be judged by their physician able to tolerate lying in the MR gantry for up to 1.5 hours.

Patient must have serum Creatinine value less than 3.0mg/dl.

Must not have any contraindication for MRI including: pacemaker or other implanted electronic device; cochlear implants; metal in the eye; embedded shrapnel fragments; cerebral aneurysm clips; or medical Infusion pumps.

Must not have an allergy to Gadolinium based contrast media.

Must not have unsatisfactory performance status as judged by the referring physician such that the patient could not tolerate an MRI scan for 1.5 hours. Examples of medical conditions that would not be accepted would include unstable angina, dyspnea at rest, severe pain at rest, and severe back pain.

Must not have intercurrent illness that requires treatment that would be jeopardized by the MRA scan.

Subjects must not require sedation for MRI studies other than administered normally for a conventional angiogram.

Must not be pregnant.

Must not be nursing mothers.

Study Design

Endpoint Classification: Safety Study, Primary Purpose: Treatment


Related Conditions & MeSH terms


Intervention

Procedure:
Magnetic resonance angiography


Locations

Country Name City State
United States Warren G. Magnuson Clinical Center (CC) Bethesda Maryland

Sponsors (1)

Lead Sponsor Collaborator
National Institutes of Health Clinical Center (CC)

Country where clinical trial is conducted

United States, 

References & Publications (3)

Prince MR, Yucel EK, Kaufman JA, Harrison DC, Geller SC. Dynamic gadolinium-enhanced three-dimensional abdominal MR arteriography. J Magn Reson Imaging. 1993 Nov-Dec;3(6):877-81. — View Citation

Prince MR. Contrast-enhanced MR angiography: theory and optimization. Magn Reson Imaging Clin N Am. 1998 May;6(2):257-67. — View Citation

Prince MR. Peripheral vascular MR angiography: the time has come. Radiology. 1998 Mar;206(3):592-3. — View Citation

See also
  Status Clinical Trial Phase
Recruiting NCT05052918 - The Effect of Exercise and Metformin on Carotid Intima-media Thickness in Patients With Prediabetes N/A
Recruiting NCT04511234 - Sirolimus Coated Balloon Versus Standard Balloon for SFA and Popliteal Artery Disease N/A
Completed NCT05906797 - Impact of Non-surgical Periodontal Therapy in the Improvement of Early Endothelial Dysfunction in Subjects With Periodontitis. N/A
Completed NCT03273972 - INvestigating the Lowest Threshold of Vascular bENefits From LDL Lowering With a PCSK9 InhibiTor in healthY Volunteers N/A
Suspended NCT02932176 - Machine Learning for Handheld Vascular Studies
Recruiting NCT05158257 - Clinical Of Plain Balloon Dilatation Combined Stent Versus Endovascular Debulking Combined Drug-coated Balloon to Treat Arteriosclerosis Occlusive Disease of Lower Extremity N/A
Completed NCT01212900 - Randomized Trial of Imaging Versus Risk Factor-Based Therapy for Plaque Regression Phase 4
Completed NCT03697382 - Effect of Daily Steps on Fat Metabolism N/A
Recruiting NCT06230406 - T-Mem GEne in Atherosclerosis
Completed NCT03654313 - Single and Multiple Ascending Doses of MEDI6570 in Subjects With Type 2 Diabetes Mellitus Phase 1
Completed NCT00382564 - Magnetic Resonance Angiography to Diagnose Atherosclerotic Disease N/A
Recruiting NCT02894931 - Effects of Dietary Interventions on Serum and Macrophage Atherogenicity N/A
Not yet recruiting NCT02578355 - National Plaque Registry and Database N/A
Completed NCT02998918 - Effects of Short-term Curcumin and Multi-polyphenol Supplementation on the Anti-inflammatory Properties of HDL N/A
Recruiting NCT02265250 - Pilot Study-Magnetic Resonance Imaging for Global Atherosclerosis Risk Assessment
Completed NCT02224339 - New Technologies to Determine Carotid Plaque Vulnerability
Completed NCT02268513 - Mediators of Atherosclerosis in South Asians Living in America (MASALA) Social Network Study
Completed NCT03393377 - Preventive Arterial Wall Phenotype and Low-dose Fluvastatin/Valsartan Combination N/A
Completed NCT02377310 - Pd/Pa vs iFRâ„¢ in an Unselected Population Referred for Invasive Angiography N/A
Not yet recruiting NCT01923012 - Phase II Randomized Placebo-controlled Study With Vitamin K2 in Asymptomatic Calcified Carotid Stenosis Phase 2