Clinical Trials Logo

Clinical Trial Summary

Background: Some people have a condition in which the wall (septum) that separates the two main pumping chambers of the heart is too thick. This thick septum causes a condition called "left ventricular outflow tract obstruction" (LVOTO), which reduces blood flow out of the heart. LVOTO can cause serious heart disease; symptoms may include shortness of breath, chest pain, heart failure, or death. Researchers want to find better ways to treat LVOTO. Objective: To test a new procedure where excess tissue is sliced away from the septum in people with LVOTO. This procedure is called "septal scoring along midline endocardium" (SESAME). Eligibility: Adults aged 21 years with LVOTO. Design: Participants will have baseline tests. They will have imaging scans and tests of their heart structure and function. They will take a walking test and answer questions about how their heart condition affects their life. Participants will stay in the hospital 2 to 6 days for the SESAME procedure. They will be completely or partially asleep for the procedure. A tube will be inserted into the mouth and down the throat to take pictures of the heart. Pictures may also be taken with a tube inserted inside the heart. Next, tubes will be inserted into the groin and guided through the blood vessels up to the heart. Guidewires will be inserted into the heart. Doctors will watch the path the wires take with x-rays and ultrasound. When the wire is in the correct place, it will be electrified to slice excess tissue away from the septum. Participants will have 3 follow-up visits within 1 year....


Clinical Trial Description

Cardiac interventricular septal reduction therapies - to relieve left ventricular outflow tract obstruction from transcatheter valve replacement or hypertrophic cardiomyopathy - have inherent limitations including dependence on coronary anatomy, high pacemaker implantation rate, and surgical morbidity. We developed a novel transcatheter ventricular myotomy called SEptal Scoring Along the Midline Endocardium (SESAME) that relies on intramyocardial guidewire navigation and transcatheter electrosurgery. SESAME has been performed on a small number of patients using off label devices. This study systematically characterizes the safety and early feasibility of SESAME at 1 enrolling site. SESAME is performed as septal reduction therapy in a heterogeneous group of subjects, including symptomatic hypertrophic cardiomyopathy and resting or provoked left ventricular outflow obstruction (LVOTO); and severe symptomatic mitral and/or aortic valve disease at high risk of standard heart surgical therapy and requiring later transcatheter heart valve implantation combined with manifest or potential LVOTO. A key goal of this study is to attempt to capture generalizable knowledge from as many patients as possible, and to add a limited number of research procedures to characterize the safety and provisional effectiveness of SESAME. Absent realistic non-clinical models of HCM or LVH combined with aortomitral disease, we believe little more information can be gleaned without clinical investigation. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06269640
Study type Interventional
Source National Institutes of Health Clinical Center (CC)
Contact Annette Stine, R.N.
Phone (301) 402-5558
Email stinea@nhlbi.nih.gov
Status Not yet recruiting
Phase N/A
Start date June 26, 2024
Completion date October 1, 2027

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease