Clinical Trials Logo

Clinical Trial Summary

The aim of this study is to evaluate the rate and anatomy of the aortic wall and leaflet calcification of the FS prosthesis implanted as full root in patients younger than 60 years compared to a stented bioprostheses (Perimount Magna Ease, PM). A 3D CT scan will be used to assess the calcification score and to determine the relationship between calcification and aortic valve leaflet.


Clinical Trial Description

A recent update of the American Hear Association and American College of Cardiology Guidelines for the Management of Patients With Valvular Heart Disease1 recommended that for patients between 50 and 70 years of age, it is reasonable to the choice of either a mechanical or bioprosthetic valve; the threshold for biological valves continues to decrease and more younger adults will receive this kind of prosthesis. However the best biological option for these patients is still a matter of debate. Stented bio-prosthesis is the most common choice. However, the predicted 15-year risk of needing reoperation because of structural deterioration is 22% for patients 50 years of age2. In the late 80's stentless valve as the Medtronic Freestyle (FS) has been introduced with the hope that it may provide physiological flow in the aortic root, sinuses, and coronary orifices and a low risk of thromboembolism. Several randomized study and meta-analysis demonstrated improved hemodynamic, a larger orifice area and a midterm survival advantage of stentless aortic valve compared to stented aortic valve replacement3, 4. The FS valve is believed to provide greater durability and superior hemodynamic performance due to the low mechanical stress on the leaflet tissues. The failure mode of the FS is thought to be mostly calcification of the aorta wall and cusp tears because collagen degradation5. This phenomenon is inflammation mediated process. Aim of this study is to evaluate the rate and anatomy of the aortic wall and leaflet calcification of the FS prosthesis implanted as full root in patients younger than 60 years compared to a stented bioprostheses (Perimount Magna Ease, PM). A 3D CT scan will be used to assess the calcification score and to determine the relationship between calcification and aortic valve leaflet. Between 2007 and 2017, among patients younger than 60 years of age, 51 patients underwent a full root replacement with a FS and 49 received a Perimount Magna Ease prosthesis. Those patients will undergo a 3D CT scan. The group of the patient with PM will be matched in function of age and interval of follow-up with the FS group. A transthoracic echocardiogram will be performed to check residual valve insufficiency and trans-valvular gradients. A cardiopulmonary exercise test ( with extraction of maximal oxygen consumption ) combined with a trans thoracic echocardiography (stress echocardiography) will be performed to evaluate the patients exercise capacity and its influence on the cardiac and valve function. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04359030
Study type Observational
Source Ziekenhuis Oost-Limburg
Contact matteo pettinari
Phone +3289327077
Email matteo.pettinari@zol.be
Status Recruiting
Phase
Start date November 15, 2021
Completion date October 1, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT04149600 - Identification of Genetic Causes of Calcific Aortic Valve Disease
Recruiting NCT06001489 - The Effects of 360-degree Virtual Reality on Pre-procedural Anxiety in Patients Awaiting Elective Cardiac Surgery Involving a Sternotomy N/A
Not yet recruiting NCT04430972 - Immune Responsiveness and Outcome After Aortic Valve Surgery (Measure)
Completed NCT02467062 - Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease. N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Terminated NCT02128841 - Comparison of Antithrombotic Treatments After Aortic Valve Replacement. Rivaroxaban: A New Antithrombotic Treatment for Patients With Mechanical Prosthetic Aortic Heart Valve. Phase 2
Active, not recruiting NCT01194362 - A Study to Identify Differences in Gene Expression in Patients With Bicuspid and Tricuspid Valve Disease
Not yet recruiting NCT05975567 - Deploying Novel Imaging Modalities Towards a Three-dimensional (3D) CARDIOvascular PATHology
Recruiting NCT06025149 - The Study on the Use of "UniLine" Bioprosthesis in the Treatment of Isolated Aortic and Mitral Valve Diseases
Completed NCT05082337 - The SAVVY Guidewire in Transcatheter Aortic Valve Replacement Procedures N/A
Completed NCT05193760 - Robustness Check of Placement and Measurement Algorithms for Blood Flow Measurement on Common Carotid Artery
Not yet recruiting NCT05941455 - A Prospective Multicenter Pivotal Study to Evaluate Safety and Effectiveness of Venus-Neo Surgical Aortic Valve N/A
Active, not recruiting NCT04950192 - Philips Intracardiac Echocardiography (ICE) Clinical Registry
Active, not recruiting NCT03924661 - SJM Masters HP 15mm Rotatable Mechanical Heart Valve as Aortic Valve Replacement Therapy
Completed NCT04073875 - 18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis
Recruiting NCT03121053 - Preventing contrAst Induced Nephropathy After TranscathEter Aortic Valve Replacement Phase 4
Completed NCT02000544 - Clinical Evaluation of a Modular Extracorporeal Circulation Circuit N/A
Completed NCT02688153 - EDWARDS INTUITY Valve System CADENCE Study N/A
Completed NCT02981004 - PAR I - Patient-to-Annulus Relation I
Recruiting NCT06126367 - Assessment of Lipoprotein(a) and Endogenous Fibrinolysis in Atherosclerotic Cardiovascular Disease/Aortic Valve Disease